Loading...
02-830-032c N x 0 M I w t i a rL N ul 12 N 0 N 0 rn t\ 0 rn 3 v 0 ul a I 00 N 0 ul 00 N 3 3 w C3 z U 0 M z3 �0 J r m SHEET METAL JOINT COVER PLATE 6" WIDE MIN. -SET IN TWO BEADS OF SEALANT PRE -FIN ALUM. PARAPET CAP HIGH - DOMED, CAPPED, GASKETED FASTENERS (APPROX. 18" O.C.) VERIFY W/ STRUCT. CONTINUOUS SHEET MEMBRANE LINER FASTENERS ® 8" O.C. CONTINUOUS TAPERED P.T. WOOD SHIM D.T. WOOD NAILER 'RIME CONCRETE UULTIPLE -PLY BUILT -UP ROOF SYSTEM ON RIGID INSUL. ON VITL. ROOF DECK NOTES: 1. THIS DETAIL SHOULD BE USED ONLY WHEN THE ROOF DECK IS SUPPORTED BY THE WALL. 2. ATTACH NAILER TO DECK WITH SUITABLE FASTENERS. 3. OPTION: IF WOOD NAILERS ARE NOT USED, A FIBER CANT STRIP SET IN BITUMEN OR ADHESIVE MAY BE USED. rli"WRAPET CAP/ BASE FLASHING 504 SCALE: N.T.S. 13 MACHINE 504 SCALE: N.T.S. 8" BELOW MACHINE ROOM BAR JOIST INSULATION - FILL AFTER TUBING IS INSTALLED 14 GAUGE ALUMINUM 2" x 13" 14 GAUGE ALUMINUM CAP SCREW SECURE - 3' -4 "W x 8 "H OPENING 14 GAUGE ALUMINUM 14 GAUGE ALUMINUM 1' -0' 0' 2 x 12 PT BLOCKING HOOD - 4' -0 "W. FLASH I MOUNT TO ROOF DECK ® TOP AND SIDES FIBER CANT (CONT.) FELT FELT FLASHING BUILT -UP ROOF I— VENTED BASE SHT. REFRIGERATION PIPING BY WINN -DIXIE ri" OPENING THROUGH REAR WALL 504 SCALE: 3/4 "= 1' -0" NOTE: EMERGENCY GENERATOR, TRANSFER SWITCH, SPECIAL ACCESSORIES FOR GENERATOR & UNDER VOLTAGE SENSING UNIT TO BE FURNISHED & INSTALLED BY CONTRACTOR. . V.T SUPPORT BY THREADED ROD & CLAMP 1 1/4" RESIDENTIAL MUFFLER SHORT RADIUS 90'ELBOW MACHINE ROOM S.S. FLEX — 1 1/4" NPT.x EMERGENCY GENERATOR —MACHINE ROOM 2' -0' min. FINISH FLOOR EMERGENCY GENEF )04/ SCALE: N.T.S. EXHAUST TO BE 3" MINIMUM BEYOND WALL, 6" MAXIMUM THIS SECTION OF DUCT TO BE INSTALLED IN SUCH A WAY THAT IT CAN BE REMOVED FOR SERVICE. FASTEN TO WALL ON OUTSIDE 3' x 3' ALUMINUM LOUVERED GRILLE SEALANT BEHIND FLANGE TOR DETAIL ATTACH RTU TO CURB ASS'Y. W ROOF TOP #10 -16 METAL SCREWS @ 16 "O.C. MAX. MECHANICAL - - - -- ROOF CURB: ATTACH TO STEEL ANGLE SUPPORTS W/ POWER DRIVEN FASTENERS UNIT "RTU . "PDF" (0.177" SHANK DIA.) ® 32" O.C. MAX. SIZE & LOC. /OPG. VARY L3xVTx1 /4; VT. LEG MAY VARY W/ ROOF CONST. AND MECH.- COORD. W/ MECH. G.C. SHALL COORD. CONTRACTOR t I — L4x4x1 /4 — JOIST: SEE PLAN T FAN DETAILS NOTE: PROVIDE #3 BAR ® 6" O.C. EA. WAY AT ALL MECHANICAL OPENINGS 2 x 6 PT WOOD BLOCKING, I LROOF INSULATION SCREW FASTEN 0 12" O.C. STAGGERED SIDE TO SIDE. METAL DECK COUNTERSINK SCREWHEADS. NOTE: REFRIG'N TUBING & HOLES WILL BE CUT BY TENANT. 4 THROUGH ROOF REF. PIPING ENCLOSURE 504 SCALE: N.T.S. NOTE: CREATE A FOAM SEAL AT ALL PENETRATIONS THROUGH ROOF AND WALLS ( PREFAB OR OTHER WISE ) OPENINGS AFTER WINN -DIXIE HAS INSTALLED AND INSPECTED THE LINES FOR LEAKS. VERIFY WITH WINN- DIXIE. NON- SHRINK GROUT- POURABLE SEALER - PITCH PAN ROOF CEMENT OR - SEALANT AT PENETRATION TO MEMBRANE JUNCTION MODIFIED BITUMEN - FLASHING PLY FELT FLASHING BUILT -UP ROOF ---n 2 ", 4" . 4" . 4" VENTED BASE SHEET ROOF INSULATION PENETRATION LZPT WOOD BLOCKING METAL ROOF DECK r9_'_JYP. ROOF PENETRATION 504 SCALE: 1 1/2"= 1' -0" NOTE: THIS DETAIL MAY BE REQUIRED IN LIEU OF THE STANDARD CURB DETAIL. CONSULT YOUR LOCAL BUILDING OFFICIALS. BRACKET WITH 9/16" Rw a OLT, LOCKWASHERS, w 0 ,I , o eee•• V% VENTED BASE SHEET ROOF INSULATION PENETRATION LZPT WOOD BLOCKING METAL ROOF DECK r9_'_JYP. ROOF PENETRATION 504 SCALE: 1 1/2"= 1' -0" NOTE: THIS DETAIL MAY BE REQUIRED IN LIEU OF THE STANDARD CURB DETAIL. CONSULT YOUR LOCAL BUILDING OFFICIALS. ri ROOF TOP UNIT CURB DTL. 504 SCALE: N.T.S. UNIT MOUNTING CURB SEALING MATERIAL P.T. WOOD NAILER — z_ 0 -SHEET METAL FLASHING RECEIVER HIGH - DOMED, CAPPED, - GASKETED FASTENERS (APPROX. 18" O.C.) VERIFY W/ STRUCT. REMOVABLE SHEET METAL COUNTER FLASHING FASTENERS APPROX. 8" 0. C. MULTIPLE -PLY MEMBRANE BASE FLASHING H I MULTIPLE -PLY BUILT -UP ROOF SYSTEM ON RIGID INSUL. ON MTL. ROOF DECK ALTERNATE CURB BEARING LOCATION FOR HEAVY WEIGHT NOTES: LOADING CONDITIONS 1. THE CURB'S TOP WOOD NAILER, AND SEAL STRIP ARE TO BE SUPPLIED BY THE CURB MANUFACTURER. 2. ATTACH NAILER TO DECK WITH SUITABLE FASTENERS. 3. WHEN POSSIBLE, THE MECHANICAL UNITS SHOULD NOT BE SET UNTIL THE ROOF MEMBRANE AND FLASHING HAVE BEEN INSTALLED. 19 CURB DETAIL FOR R.T.U.'S 504 SCALE: N.T.S. PT BLOCKING FOR FAN SUPPORT �§Allffllffl"FWE FAN BASE, SECURE TO ROOF SYSTEM (MINIMUM OF TWO PLACE SIDE) FLASHING CANT STRIP CONTINUOUS BUILT -UP ROOF rlo_' TYP. FAN CURB DETAIL 504 SCALE: 1"= 1' -0" SEALANT DRAW BAND POURABLE SEALANT NON- SHRINK GROUT ROOF CEMENT OR SEALANT AT PENETRATION TO MEMBRANE JUNCTURE WATERTIGHT SHEET METAL RAIN COLLAR OVERLAPPING PENETRATION POCKET SHEET METAL PITCH PAN, SOLDERED /WELDED WATERTIGHT (4" MIN. HEIGHT) 4" MIN. FLANGE, SET IN ROOF CEMENT OVER BUILT -UP ROOFING PLIES, PRIME FLANGE BEFORE STRIPPING MULTIPLE -PLY MEMBRANE STRIPPING PLIES MULTIPLE -PLY BUILT -UP ROOF MEMBRANE LL-THERMAL INSULATION 1" MIN. ROOF DECK PIPE DIAMETER 20 ELECTRICAL CONDUIT ROOF PENETRA 504 SCALE: N.T.S. acN N t� W r1 ~ U I- Wo W W 0 0 ItJ In In l W (n H o- I Q 00 Ln U N W r. ° o Z J MO 0 U p� - QQI rQ � �Q � I� Lo - ry - } -;; 111 � • `••: 4' ENGINEERS REVISIONS: N cv M LM c q Eoz L A C �" 0 L73CL i wM �-Z4 A, w N co) w0) 0. cis r4 w o: v O LLJ z o ®o v 0 ® o v q 0 0 a BRACKET WITH 9/16" Rw a OLT, LOCKWASHERS, w 0 ,I , o AND NUTS (TYP.). V% LL CABLE "LOOPED" THROUGH BRACKET AND CLAMPED (TYP.) 1/4" AIRCRAFT — STRANDED/ TWISTED z S.S. CONTROL CABLE z 0 D BRACKET WITH 9/16" BOLT CABLE BRACKET O OLT, LOCKWASHERS, THROUGH CURB AND AND NUTS (TYP.) NAILER 9/16" BOLT, LOCKWASHERS, METAL CURB AND NUTS (TYP.) NOTES: L3x3x3/16 1. METAL CURBS MUST BE WELD TO ROOF SECURELY FASTENED TO OPENING FRAME STRUCTURAL STEEL. 2. CABLE RESTRAINTS TO BE PROVIDED AT EACH CORNER AND AT THE MIDPOINTS OF EACH UNIT (TOTAL OF SIX) AND SHALL LIMIT VERTICAL MOVEMENT TO NO MORE THAN 5/8 INCH. ri ROOF TOP UNIT CURB DTL. 504 SCALE: N.T.S. UNIT MOUNTING CURB SEALING MATERIAL P.T. WOOD NAILER — z_ 0 -SHEET METAL FLASHING RECEIVER HIGH - DOMED, CAPPED, - GASKETED FASTENERS (APPROX. 18" O.C.) VERIFY W/ STRUCT. REMOVABLE SHEET METAL COUNTER FLASHING FASTENERS APPROX. 8" 0. C. MULTIPLE -PLY MEMBRANE BASE FLASHING H I MULTIPLE -PLY BUILT -UP ROOF SYSTEM ON RIGID INSUL. ON MTL. ROOF DECK ALTERNATE CURB BEARING LOCATION FOR HEAVY WEIGHT NOTES: LOADING CONDITIONS 1. THE CURB'S TOP WOOD NAILER, AND SEAL STRIP ARE TO BE SUPPLIED BY THE CURB MANUFACTURER. 2. ATTACH NAILER TO DECK WITH SUITABLE FASTENERS. 3. WHEN POSSIBLE, THE MECHANICAL UNITS SHOULD NOT BE SET UNTIL THE ROOF MEMBRANE AND FLASHING HAVE BEEN INSTALLED. 19 CURB DETAIL FOR R.T.U.'S 504 SCALE: N.T.S. PT BLOCKING FOR FAN SUPPORT �§Allffllffl"FWE FAN BASE, SECURE TO ROOF SYSTEM (MINIMUM OF TWO PLACE SIDE) FLASHING CANT STRIP CONTINUOUS BUILT -UP ROOF rlo_' TYP. FAN CURB DETAIL 504 SCALE: 1"= 1' -0" SEALANT DRAW BAND POURABLE SEALANT NON- SHRINK GROUT ROOF CEMENT OR SEALANT AT PENETRATION TO MEMBRANE JUNCTURE WATERTIGHT SHEET METAL RAIN COLLAR OVERLAPPING PENETRATION POCKET SHEET METAL PITCH PAN, SOLDERED /WELDED WATERTIGHT (4" MIN. HEIGHT) 4" MIN. FLANGE, SET IN ROOF CEMENT OVER BUILT -UP ROOFING PLIES, PRIME FLANGE BEFORE STRIPPING MULTIPLE -PLY MEMBRANE STRIPPING PLIES MULTIPLE -PLY BUILT -UP ROOF MEMBRANE LL-THERMAL INSULATION 1" MIN. ROOF DECK PIPE DIAMETER 20 ELECTRICAL CONDUIT ROOF PENETRA 504 SCALE: N.T.S. acN N t� W r1 ~ U I- Wo W W 0 0 ItJ In In l W (n H o- I Q 00 Ln U N W r. ° o Z J MO 0 U p� - QQI rQ � �Q � I� Lo - ry - } -;; 111 � • `••: 4' ENGINEERS REVISIONS: N cv M LM c q Eoz L A C �" 0 L73CL i wM �-Z4 A, w N co) w0) 0. cis r4 w o: v O LLJ z o ®o v 0 ® o v q 0 0 a r � DATE: JUNE 17, 2002 DRAWN BY. CHECKED BY: DIVISION MIAMI LOCATION NO. 285 W.D. GUIDE PLAN PROJECT NO. WD #0704 DRAWING NO. A -M of SHEET NO. OF Rw a w 0 ,I , o V% LL .�„ Ul z 2 z 0 D j 00 O 4 r � DATE: JUNE 17, 2002 DRAWN BY. CHECKED BY: DIVISION MIAMI LOCATION NO. 285 W.D. GUIDE PLAN PROJECT NO. WD #0704 DRAWING NO. A -M of SHEET NO. OF