02-830-025ro-
N
x
0
M
I
L
s
i
Q
IL
00
v
N
0
0
N
O
rn
0
rn
3
.a
0
M
Q
I
00
N
0
ul
00
N
0
v
3
w
V,AnTW 11t= nrv)p
CONCRETE CURB
DOOR
DOOR FRAME
WALL
CURB @ DOORS TYP.
A307 SCALE: 1 -1/2' = 1' -0'
CONCRETE CURB
WALL
2 CURB @ CORNERS TYP.
A307 SCALE: 1 -1/2' = 1' -0'
PRE -FAB COOLER/
FREEZER EXT, WALL
CAULK FLASHING TO
063 ALUMINUM CLOTH FREEZER EXT, WALL
AND CLOSURE ANGLE POP RIVET FLASHING
INTERIOR ❑ FASTENED TO WALL TO COOLER /FREEZER &
WALL EXTERIOR & COOLER /FREEZER CONCRETE SLAB
WALL
CONCRETE CURB ,063 ALUMINUM
CONCRETE SLAB 6° is FLASHING
a
a e d a
a
4.0 cD
a o
a a
o °
a
a
a 4 a °a CAULK FLASHING TO
CONCRETE SLAB
. a
a
COOLER /FREEZER DETAILS
6 EXTERIOR CORNER 7 FLASHING @ BASE
A307 SCALE: 1 -1/2' = 1' -0' A307 SCALE: 1 -1/2' = 1' -0'
COOLER
vi
_ z
co
PRE - FABRICATED I
IVIC^T QUTTINV; RVUM A
POWER FASTEN SCREED
TO FLOOR (TYP,
6' x 6' QUARRY TIL vv
@ 45' ANGLE vvv
(TYPICAL)
vvv
GROUT BED QUARRY TILE
vvv FLOOR (TYP,)
Ck +2' A.F,F,L.
nj
N �
_ a _
a ° a d a
a
SECTION @ COOLER
A307 SCALE: 1 -1/2' = 1' -0'
IJ
N
0' -0'
F.F.
WALL CONT, SEALANT
GROUT ANY AND
ALL GAPS BETWEEN 4„
WALL
VISQUEEN BARRIER
@ COOLER AND
FREEZER WALL
#3 BAR CONT, ._� FINISH FLOOR
LAP JOINTS 8' MI U")
a a
d ° a
a a
a
a
CONCRETE CURB
ANCHOR W/ #3 BAR
@24'O.C,
3 SECTION THRU EXT. CURB TYP.
A307 SCALE: 1 -1/2' = 1' -0'
8 )COOLER /FREEZER /RET
307 J SCALE: 1 -1/2' = V -0'
2x6
AT I
9�SECTION THRUTHRU
A307 SCALE: 3/4' = 1' -0'
10' -6 1/2' A.F,F,
COOLER HEIGHT START RAMP AT
EDGE OF DOOR
ZE -FAB COOLER
ALL
2 ❑DUCE
ZEP
9'-0' A.F.F.
CEILING HEIGHT
FINISH FLOOR 0' -0"
1SPENDED CEILING
DET
AREA/ MEAT
IRE ON 2x4 MTL
MEAT CUTTING
:ERS T❑ STRUCTI
S REQUIRED, —
N VENT
PRE -FAB
V1EAT CUTTING
ROOM
MTL. STUDS @ 24' O.C.
'❑WER FASTEN SCREED
'❑ FLOOR (TYPICAL)
.'x6' QUARRY TILE @ 45'
UI
z
z
C
0
w
z
0
Q�I
J
ra
w
U
N POP RIVET ALUMINUM
o ANGLE TO TRIM &
C3 COOLER /FREEZER
t� 063' ALUMINUM
UJ ANGLE TRIM
BUTTON H.D.
DRIVE PINY
FINISHED WALL
REF, FINISH SCHEDULE
SHEET A -601
4 JAMB @ COOL
A307 SCALE: 1 -1/2' = V -0'
PREFAB
COOLER
ZER
• COOLER OR FREEZER
WALL
FINISH FLOOR + 2" A.F.F.
RAMP DETAIL @COOLERS &FREEZERS
io
STOCKROOM
CORRIDOR
iNGLE (TYPICAL) CONCRETE CURB
'x6' QUARRY TILE FLOOR
EF.+ FIN, SCHED (TYP) 0
ORTAR BED
FINISH FLOOR
o a d
a 1 =_
III -III - III =1 I I =III=
1 -1 1 1EE1 11 =1 I E
' II -I 11- 111 =11
ROOM
2" A.F.F.
FREEZERS ONLY FREEZER FLOOR
LARGE DOORS 5' -6"
SMALL DOORS 3' -0" STORE FLOOR
LEVEL 0' -0 ".
.....
MAX RAMP
SLOPE 1:12
SEE FLOOR PLAN
FOR DIMENSION
RED WOOD- : AND LOCATION
STORE FLOOR
LEVEL 0' -0 ".
BLOCK WALL
OUTLINE
NOTE: COORDINATE WITH COOLER MANUFACTURER PRIOR TO CONSTRUCTION.
POCKET FOR HEATER CABLE
SCALE 1/2" = 1' -O"
. I
EXTERIOR BLOCK WALL
DOOR
EXTEND CONCRETE RAMP
FLOOR CONSTRUCTION
VARIES BETWEEN 2" TO 3" FROM C.B. WALL
COOLER &FREEZER. EL CONCRETE RAMP'S TO BE POUR
SEE DETAILS AFTER FRAME IS IN PLACE
FLOOR SLAB ELEV. PLAN. 2' -0" (MAX SLOPE 1:12)
SEE FLOOR PLAN FOR
+2" A.F.F. M DIMENSION AND LOCATIONS
FLOOR LEVEL ;'.• :- ••..: •.- � .�: - . _FLOOR LEVEL
0' -0„
4" CONC. SLAB
(STORE FLOOR) _
STRUCTURE TO REMAIN
UNLESS OTHERWISE NOTED
ON STRUCTURAL PLANS.
(TYPICAL)
NOTE: 1. COORDINATE WITH COOLER MANUFACTURER PRIOR TO CONSTRUCTION.:
2. FINISHED COOLER /FREEZER FLOOR TO BE +2" A.F.F.
AS PER SOUTH FLORIDA BUILDING CODE CHAPTER 4606.2 (b)(4) -
TYPICAL COOLER /FREEZER RAMP DETAIL� "` - --
SCALE 1/2" = 1' -0"
N
r� W
O
W
O
W
C) J O In
I
H0_
Q ui
• �� �� In
N W
U°
• O ZQ O
O .�
U O) �
<J
LLJ
Lo
F.�y7 V
ENGINEERS
REVISIONS:
�.
063 ALUM, RAIN HOOD
Lt1`
Li
10
HOOD SET IN PLACE
M
'p
AFTER COOLERS /FREEZERS
U,
8" ARE IN PLACE,
Eoz
A
CONTINUOUS
o
FINISHED WALL
A
a
°
REGLET
w
REF: FINISH
SCHEDULE
a°
COUNTER
A
SHEET A -601
F-
rn
U
FLASHINGS
V
W J
O
a
d
°
0 u
z
MASONRY
I
V)
a°
//
LINTEL
®O
U
®
a
INTEGRAL METAL ROOF
°
& FLASHING WITH
Q
COOLER / FREEZER ROOFING
0
h
0
to
PRE -FAB
z0
063 ALUM
CO ❑LER /FREEZER
❑
N
ANGLE
TRIM—
LL91
0
o
POP RIVET ANGLE
v�
TO TRIM AND COOLER /FREEZER
a:
�w
5
HEAD
@ COOLER /FREEZER TYP.
A307
SCALE: 1
112' =
V -0'
RAMP DETAIL @COOLERS &FREEZERS
io
STOCKROOM
CORRIDOR
iNGLE (TYPICAL) CONCRETE CURB
'x6' QUARRY TILE FLOOR
EF.+ FIN, SCHED (TYP) 0
ORTAR BED
FINISH FLOOR
o a d
a 1 =_
III -III - III =1 I I =III=
1 -1 1 1EE1 11 =1 I E
' II -I 11- 111 =11
ROOM
2" A.F.F.
FREEZERS ONLY FREEZER FLOOR
LARGE DOORS 5' -6"
SMALL DOORS 3' -0" STORE FLOOR
LEVEL 0' -0 ".
.....
MAX RAMP
SLOPE 1:12
SEE FLOOR PLAN
FOR DIMENSION
RED WOOD- : AND LOCATION
STORE FLOOR
LEVEL 0' -0 ".
BLOCK WALL
OUTLINE
NOTE: COORDINATE WITH COOLER MANUFACTURER PRIOR TO CONSTRUCTION.
POCKET FOR HEATER CABLE
SCALE 1/2" = 1' -O"
. I
EXTERIOR BLOCK WALL
DOOR
EXTEND CONCRETE RAMP
FLOOR CONSTRUCTION
VARIES BETWEEN 2" TO 3" FROM C.B. WALL
COOLER &FREEZER. EL CONCRETE RAMP'S TO BE POUR
SEE DETAILS AFTER FRAME IS IN PLACE
FLOOR SLAB ELEV. PLAN. 2' -0" (MAX SLOPE 1:12)
SEE FLOOR PLAN FOR
+2" A.F.F. M DIMENSION AND LOCATIONS
FLOOR LEVEL ;'.• :- ••..: •.- � .�: - . _FLOOR LEVEL
0' -0„
4" CONC. SLAB
(STORE FLOOR) _
STRUCTURE TO REMAIN
UNLESS OTHERWISE NOTED
ON STRUCTURAL PLANS.
(TYPICAL)
NOTE: 1. COORDINATE WITH COOLER MANUFACTURER PRIOR TO CONSTRUCTION.:
2. FINISHED COOLER /FREEZER FLOOR TO BE +2" A.F.F.
AS PER SOUTH FLORIDA BUILDING CODE CHAPTER 4606.2 (b)(4) -
TYPICAL COOLER /FREEZER RAMP DETAIL� "` - --
SCALE 1/2" = 1' -0"
N
r� W
O
W
O
W
C) J O In
I
H0_
Q ui
• �� �� In
N W
U°
• O ZQ O
O .�
U O) �
<J
LLJ
Lo
F.�y7 V
ENGINEERS
REVISIONS:
i
�.
Lt1`
Li
10
M
'p
�-,
U,
Eoz
A
o
A
V) U-)
w
c3
A
w
F-
rn
U
ca
V
W J
O
V
0 u
z
ti..
I
V)
O
//
®O
U
®
A
O
W
V
Q
0
h
0
to
i
�.
Lt1`
Li
10
0
'p
�-,
U,
G
O
F-
tC)
D
_Z
O
In
//
DRAWING TITLE
META CUTTING
RM., SEAFOOD
& PROD. SECTIONS
DATE:
JUNE 17, 2002
DRAWN BY:
CHECKED BY:
DIVISION
MIAMI
LOCATION NO.
285
:W. D. GUIDE PLAN
PROJECT NO.
WD #0704
DRAWING NO.
A -307 of
SHEET NO.
OF
,