Poblanos Mexican Restaurant
5850 Sunset Drive
South Miami, Florida 33133
GENERAL NOTES:
THE WORK CONSISTS OF THE INTERIOR RENOVATION AND COMPLETION OF A NATURAL CHICKEN
GRILL OF A (APPROX.) 2243.00 S.F. (GROSS) RESTAURANT LOCATED AT 5850 SUNSET DRIVE, SOUTH
MIAMI, FLORIDA.
ALL REQUIREMENTS OF LOCAL, STATE AND NATIONAL ORDINANCES, REGULATIONS AND CODES
PERTAINING TO BUILDING AND TO THE PRESERVATION OF PUBLIC HEALTH AND SAFETY SHALL BE
STRICTLY OBSERVED BY THE GENERAL CONTRACTORS AND ALL SUB - CONTRACTORS. THE FLORIDA
BUILDING CODE, (2001) LATEST EDITION AND ALL APPLICABLE LOCAL, NATIONAL AND /OR STATE
CODES SHALL BECOME PART OF THESE PLANS AS IF BOUND HEREIN.
THE CONTRACTOR AND ALL SUB-CONTRACTORS SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO
PERFORMING ANY WORK AND SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY CONDITIONS THAT
MAY EXIST THAT ARE NOT COVERED ON THESE PLANS, ALL CHANGES OR ALTERATIONS TO THESE
PLANS MUST BE SUBMITTED IN WRITING AND APPROVED BY THE ARCHITECT PRIOR TO PERFORMING
CHANGES.
IT IS THE CONTRACTOR'S RESPONSIBILITY FOR FINANCIAL COMPENSATION DUE TO ANY CHANGES,
MODIFICATIONS, OR DEVIATIONS MADE TO THIS PROJECT WITHOUT PRIOR WRITTEN APPROVAL
FROM THE ARCHITECT.
LEGAL DESCRIPTION:
LOT 16 OF W A LARKINS ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 3, OF PAGE
198, OF THE PUBLIC RECORDS OF DADE COUNTY, FLORIDA. LOT SIZE 75.00' X 145.00'.
_ I
4" SANITARY LINE,
14 F.U.'s
GAS METER &
PRESSURE SET BY
LOCAL GAS
COMPANY
I NEW C.O.
of0
r-,I
EXIST. SAN. MANH
EXIST. 1200 GALLON
SEPTIC TANK EXIST. C.O.
/4"
ANCH
�0.
♦- GREASE WASTE LINE,
TIE �110 EIOSTNG 750
CALCREASE TRAP, 211
i FU' SEE SP-1 FOR
LocAnoN
_ I
�IO
L__ - -J
O
DESIGNATED "CONTRIBUTING STRUCTURE ".
EXEMPT FROM ANY ADDITIONAL PARKING
REQUIREMENTS.
..................................... ................ ..................................................................................................................................... ...................... ............
..............
............................................................................................................................................................................................................ ...............................
115.00'
EXISTING 4" /GREASE
I
..................
W R NTR
A.F.G.
STO
B. S.
UILDI
n co--co
G SITE PLAN
N SCALE: 1" = 10' -0"
NG CC
SW 58TH COURT
NO CHANGE OF USE OR OCCUPANCY.
NO INCREASE IN FLOOR AREA.
PREVIOUSLY APPROVED RESTAURANT USE.
EXIST. INTERIOR WORK,
THIS AREA, 1ST FLOOR ONLY
2095.70 S.F.
EXISTING ASPHALT PARKING, DO NOT
DISTURB
�1" COLD WTR. LINE STUBBED INTO SPACE
FROM EXISTING 1" METER AND BACKFLO}�1�
FIELD VERIFY S ' VICE CONNECTION
LOCATION P R TO ANY WORK.
2 STORY C.B.S
BUILDING
1 -- NO? A t'ARPIF -
C1 _ - ID C) D
IDEWALK, DO NOT DISTURB
EXISTING
CONTROL VALVE
EXISTING
WATER METERS
& BACKFLOW
DEVICES W/
CONTROL VALVE
AFTER WATER METER
2A
LOCATION MAP
NOT TO SCALE
William
hamilton
crthur
architect
Inc.
800 douglas entrance
suite 303
coral gables,
florida, 33134
(305)443 -3100
fax (305)441 -7960
license no. 2282
DRAWN BY:
M.M.H.
SEAL: f
.
I
SHEET INDEX
n
Q
w
z
0
Lij
C1
F--
w
Q
D -1 DEMOLITION PLAN AND NOTES
I—
U
0
0
zJ
-
I)
A -1 FLOOR PLAN, LEGENDS, NOTES
Q
Qz
z ���
DOOR SCHEDULES AND DETAILS
Q
(n
La.J
zw
w
w
J
L1J
I—
F=
V ' ^
�►(fl �',��
w
w
V)
z
I
SHEET INDEX
I-
w
z
Lij
CVS COVER SHEET, LOCATION MAP AND INDEX
U�
D -1 DEMOLITION PLAN AND NOTES
I
sin 0�
Q
I)
A -1 FLOOR PLAN, LEGENDS, NOTES
f-
z ���
DOOR SCHEDULES AND DETAILS
(n
N
w
I�
CA-2 PROPOSED EXTERIOR ELEVATION,
�►(fl �',��
PARTITION AND STOREFRONT DETAILS
z
v)
A -3 REFLECTED CL'G PLAN, RESTROOM
Q LLJ
PLAN AMD ELEVATIONS
FIRE PENETRATION DETAILS
V Q
— M
X -
M -1 H.V.A.C. PLAN, SCHEDULES, NOTES
w D
( ---- --
t�Lh l
AND DETAILS
�
_ MECHANICAL ROOF PLAN
M 2
M
E -1 ELECTRICAL PLAN, SCHEDULES, RISER
Q
°
O
AND NOTES
> a
`�
0�5
E -2 ELECTRICAL REFLECTED CEILING PLAN
w Q o z
Uw
P
J V)
m o M
I�
-1 SANITARY AND WATER PLUMBING PLAN
F D
P -2 SANITARY /GREASE WASTE RISER
L•J = w
0 O ° < -
o 00¢o
a- L� °w
AND WATER SERVICE RISER
I
tr
P -3 GAS PLAN AND RISER
REVISION DATE S`1
P -4 PLUMBING DETAILS
A
0
A
PROJ. NO: DATE:
05 -25 04.23.05
SHEET NO.:
CvS
1 OF 13