Loading...
05-1059-012DOOR SCHEDULE NUMBER TYPE WIDTH HEIGHT THICK MATERIAL FINISH FRAME REMARKS D1 A dbl. X-O" 7' -2" 1 -3/4" ALUM /GLASS - ALUM. 1 -LITE FRENCH, SEE DOOR NOTES BELOW. D2 A dbl. T-O" 7' -2" 1 -3/4" ALUM /GLASS - ALUM. 1 -LITE FRENCH, SEE DOOR NOTES BELOW. D3 B 3' -0" 7' -0" 1 -3/4" STEEL - STEEL NEW FIRE RATED DOOR, MIN. 3/4 HR. RATING, SEE NOTES BELOW. D4 - OPEN N0. Cn w °_° cW G � D5 C 3' -0" V -8" 1 -3/8" S.C. WOOD - WOOD SEE DOOR NOTES BELOW. D6 C 3' -0" 6' -8" 1 -3/8" S.C. WOOD - WOOD SEE DOOR NOTES BELOW. 0 "ALL INTERIOR FRAMES TO BE PRE -HUNG WOOD. • ALL INTERIOR DOORS TO BE SOLID CORE WOOD STAIN GRADE (UNLESS OTHERWISE NOTED) W /MIN. 2 COATS CLEAR OIL BASE WITH 1 -1/2" PAIR OF STANLEY OR APPROVED EQUAL 26D BRUSHED ALUMINUM FINISH HINGES. • ALL DOORS TO HAVE FLOOR MOUNTED DOOR STOPS, IVERS, PARKER OR APPROVED EQUAL. FINISH 26D BRUSHED ALUMINUM • ALL DOORS FRAMES TO BE LIGHTLY SANDED & RECEIVE (2) COATS OF OIL BASE SEMI -GLOSS PAINT, COLOR TO BE SELECTED BY OWNER • ONLY PROVIDE PANIC HARDWAREILOCKING DEVICES ON ALL EXIT DOORS AS REQUIRED BY 8- 2.2.2.3 OF N.F.P.A 101 SELECTED BY OWNER • ALL DOORS TO HAVE ADA COMPLIANT CLOSER (LCN 4040 SERIES) • ALL DOOR LEVER HARDWARE SHALL BE ADA COMPLIANT BY SCHLAGE OR EQUAL • ALL DOORS LOCATED IN THE PATH OF EGRESS SHALL BE SINGLE ACTION RELEASE WITH NO KEY, TOOL, OR SPECIAL KNOWLEGE TO OPEN FROM THE EGRESS SIDE PER F.B.C. AND F.F.P.C. DOOR-1&2 NEW "400 SERIES" WOOD OUTSWING FRENCH DOORS (IMPACT RESISTANT) AS MFG. BY "ANDERSEN CORPORATION" P.A. # 03- 0415.15, EXPIRES ON: 10/08/2008 DOOR HARDWARE BY MFG. LOCKS ET/D EADBOLT KEYED @ EXTERIOR, THUMB LATCH INTERIOR SIDE. SURFACE MOUNTED CLOSER. PUSH /PULL TO MATCH BLDG. STANDARD. 4" WIDE ALUM. THRESHOLD. PROVIDE SUBMITTAL FOR ARCHITECT APPROVAL. DOOR-3 NEW a HOUR RATED (MIN.) STL. DOOR & FRAME WITH SELF CLOSER, PROVIDE LEVER ADA COMPLIANT DOOR HARDWARE W /BRUSHED ALUM. FINISH, KEY LOCK SET. OUTSWING COMMERCIAL STL DOOR 18 GA. FLUSH DOOR AS MFG. BY "BRUNSWICK DOOR CO." OR APPROVED EQUAL. P.A. #: 02- 0610.05 EXPIRES ON 08/15/2007 PROVIDE NECESSARY HARDWARE/LOCKING DEVICES ON ALL EXIT DOORS AS REQUIRED BY 8- 2.2.2.3 OF N.F.P.A 101 & PER F.B.C. 1019.7.2. DOOR-5&6 PROVIDE CLOSER, ADA PRIVACY LOCK, S.S. KICK PLATE, ADA COMPLIANT SIGN TO SIDE OF JAMB; DOOR 5: WOMEN; DOOR 6: MEN. SEE ADA COMPLIANT SIGN SPECS ON SHT. A-4. WINDOW NOTES: NEW "400 SERIES" PERMA SHIELD WOOD CASEMENT WINDOWS WITH VINYL CLADDING ON EXTERIOR (IMPACT RESISTANT) AS MFG. BY "ANDERSEN CORPORATION" P.A. # 02- 0603.01, EXPIRES ON: 09/19/2007 DOOR TYPES: 1 #5 DOWELLED INTO EXIST. BEAM MIN. 4 ", EPDXY GROUT & W/ SPLICE MIN. 48 BAR DIA W/ 1#5. EXISTING CONT. 8"X 12" POURED CONC. BEAM W/ (2);17 RODS TOP & BOTTOM BLACK VINYL LETTERING/ NUMBERS AT EXTERIO +47.0 DOOR _78 0 O �I O 8"X 8" CONC. COL. EA OUTSWING COMMERCIAL SIDE OF DOOR W/ 1#5 18 GA. FLUSH STL DOOR AS STEEL KICK DOWEL INTO FTG. MIN. MFG. BY "BRUNSWICK DOOR PLATES EA. SIDE 4 ", EPDXY GROUT & W/ CO." OR APPROVED EQUAL SPLICE MIN. 48 BAR DIA N.O.A. #: 02- 0610.05 W/ 1 #5 ROD. EXPIRES ON 08/15/2007 FIRE PROTECTION AND ACCESSIBILITY NOTES: SPACE IS NOT FIRE SPRINKLERED. CONTRACTOR SHALL PROVIDE ONE CLASS "ABC" TYPE FIRE EXTINGUISHER FOR EVERY 3000 S.F. OF BUILDING AREA AND ONE CLASS TYPE "K" AT COOKING AREA. EXTINGUISHERS SHALL BE MOUNTED @ 60" A.F.F. MAX. PROVIDE EXTINGUISHER CABINET IN ALL AREAS, SQUARE TRIM CABINET WITH "VERTICAL DUO" DOOR WITH WHITE BAKED ENAMEL FINISH AS MFR. BY LARSEN OR EQUAL. COORDINATE LOCATION WITH OWNER PRIOR TO INSTALLATION. THERE IS AN ACCESSIBLE ROUTE FOR THE PUBLIC FROM ACCESSIBLE PARKING SPACES THROUGH WALKWAY TO ENTRY DOORS AND INTO BUILDING. ALL PUBLIC AREAS ARE ACCESSIBLE AND HAVE NO LEVEL CHANGES GREATER THAN 1/2" D7n 511 . , A-4 2 5' -9" 5' -9" �� " i �� 4 ,I 5 D 40 i 24 2 18 CA O LO z U) W r LO N iFA F: �Al S "K" ADA COMPLQ0 I COMPLIANT FE PORTABLE FIRE EXTINGUISHER ; I • I I'I WOMENS MENS I : Y... I , I . li I 6 _ - -- RESTROOMM 1'5 RESTROOM I 1 L - J 7 8 � L=J- .I i "' I` E1;- 14 G - - - - - - 13 KI CHEN _ - COOKING LINE F f ��❑F 1 Ell _ 9 ch l `O 4a J' 17 DISH l ASS THFtt� - S' li ! WASHING F�A V ESTIBULE D6 & 000 17 STORAGE 4a WAITER STATION - _ -- 5" (5 WSYSTES? TO BE INSTALLED II$ ACC E WITH N.F -F, 3 5/8" STL. STUD - W / 2X4 @ DOOR JAMBS MEN HOLLOW METAL FRAME ATTACHED W/Z -CLIP TO STUDS- 3 PER JAMB (GROUT FILLED) 1/2" GREENBOARD ON 3 5/8" STEEL STUDS @ 24" O.C. CONTINUOUS SEALANT BOTH SIDES JAMB INTERIOR DOOR JAMB DTL. 5/8" STUCCO EXTERIOR LOOSE 'T" ANCHOR PER DOOR MANUF. D CORE DOOR -CAULK CONT @ PERIMETER OF FRAME DOOR 3 ANCHORS PER JAMB 18 GA HOLLOW METAL FRAME 5 3/4" CAULK CONT @ PERIMETER OF FRAME 1/2" DRYWALL ON 3/4" ' FURRING EXTERIOR DOOR JAMB DETAIL ,9 KEY LEGEND: O I. NEW CASEMENT WINDOWS IN EXISTING OPENINGS, SEE SPECIFICATIONS AND DETAILS ON FOLLOWING SHEETS. �/ 2. EXIST. EXTERIOR CONCRETE BLOCK WALL CONSTRUCTION, PATCH & REPAIR SYSTEM TO BE DRYWALL SIDE AS REQUIRED FOR NEW WALL FINISHES. INSTALL5049 ACC NCE: - 3. EXISTING 2 -HR. DEMISING WALL, DO NOT DISTURB EXCEPT TO PATCH & - - WITH I(d.F P.A. REPAIR AS REQUIRED TO COMPLY W/ NECESSARY FIRE RATING & WALL 20 FINISHES. 4. TYPICAL INTERIOR PARTITION WITH Y2" GREENBOARD EACH SIDE OF 25 GA. 35/8" STL. STUDS @ 16" O.C. +6" ABOVE CEILING HGT. 2�EXISTING PORTICIti'3 C:" `~!j ;!.DINGS SHALL COMPLY 4a. SAME AS "4" EXCEPT RUN TO ROOF DECK & INSULATE WITH 4" BATT WITH THE PRO, IISI i"N:1 OF Ekl`3TIPdG OCCUPANCIES, INSULATION. AS SET FORTH IN THE FLORIDA FIRE PREVENTION CODE. 5. TYPICAL INTERIOR PARTITION WITH Y2" GREENBOARD EACH SIDE OF 20 GA. 6" STL. STUDS @ 16" O.C. TO ROOF DECK, INSULATE W /4" BATT INSULATION. 1 6. TYPICAL INTERIOR PARTITION WITH Y2" GYPSUM BD. EACH SIDE OF 25 GA. 35/8" STL. STUDS @ 16" O.C. +6" ABOVE CEILING HGT., SEE TYP. PARTITION DTL., 3 ,r, SHT. A -3. PRO y ONE CERTIFIED " " 12 11 ❑B ❑D ❑F I❑ 2�.- �ty►�+ FI 6a. SAME AS 6 EXCEPT WITH A RADIUS OF 8'-8"±. 4 _ _ 12' -8" �� 4' -0" 8' -11 " ti'i,� 1 s ..� Siff. 7. DRYWALL CASED ARCHED OPENING, 4' -Ow WIDE. HEIGHT OF ARCHWAY SHALL SERVICE 7 15 - _ K E � - _- "� __ J 7 CID 3' -0" 3' -0" 10 - 6 6a CI 6 iA SERVICE 11 g N 4r -5rr 8 1 I 1 BAR 9 ( 7 7 1 U COUNTER I SEATING (7 SEATS) WAITING NG SEATING CAP CI (7 SEAT SIGN: 36 PER O ; °v �y l� 2 O�C;`yQ N FLOOR PLAN SCALE: 1/4" = V -0" 2 8 DINING AREA a a a a CLASS "2A10BC" PORTABLE FIRE EX INGUISHER 44" 3' -0" < 3' -0" SEATING 8:) (36 SEATS) _ E L 57' -2" EXISTING DIM. 6 N NOT A PART EXISTING �C DOOR, NOT A PART OF e DINING �o� BE AT 7' -0" A.F.F., SEE ELEVATIONS #1 & 2, SHT. A -4. g2�,j vdi[t1 a r a imam 23 : ^:�zPEI reach of T'' TYPICAL INTERIOR PARTITION WITH Y" GYPSUM BD EACH SIDE OF 25 GA 35/" SEATING (18 SEATS) rc� q EXIT Top notfi;:z1v' �. 8. 2 8 above the floor STL. STUDS @ 16" O.C. +5' -0" A.F.F. WITH STL. TUBE RAILING ABOVE. RAILING TO BE DETERMINED BY "POBLANOS" REPRESENTATIVE, SUBMIT SHOP DRAWINGS FOR APPROVAL. 9. MILLWORK ITEM BY TENANT. 10. MILLWORK ITEM BY TENANT, SECTION OF SERVICE COUNTER DROPPED TO 34" HIGH (MAX.) FOR HANDICAP ACCESSIBILITY. 11. WATER FEATURE TO BE DETERMINED. FINISH LEGEND: ❑ A. PREPARE EXIST. CONC. SLAB FOR NEW FLOOR COVERING. NEW CERAMIC TILE FLOOR AND BASE T.B.D., FOR BIDDING PURPOSES ONLY, PROVIDE 3.00 /S.F. ALLOWANCE FOR MATER I AL ONLY . B. PROVIDE & INSTALL "RESTAURANT" STANDARD 6"X6" QUARRY TILE THROUGHOUT KITCHEN AND CAFE AREA. C. 6" COVE TILE BASE TO MATCH FLOOR. D. 6" QUARRY TILE BASE TO MATCH FLOOR AREAS. E. 4" VINYL COVE BASE 3 D. DRYWALL PAINTED W/ MIN. (2) COATS ON PRIMER EGGSHELL, COLOR DETERMINED BY "POBLANOS" REPRESENTTIVE. F. PAINT ALL WALLS, TOP OF BASE TO CEILING WITH WHITE EPDXY PAINT. G. STAINLESS STL.BACK SPLASH FROM TOP OF BASE TO BOTTOM OF HOODS. H. DECORATIVE BACK SPLASH WALL TILE FROM TOP OF COUNTER TO BOTTOM OF CABINETS. PROVIDE $2.00 ALLOWANCE FOR TILE ONLY. LABOR & MATERIAL SHALL BE PART OF BID. Y" DRYWALL CEILING, TAPED, SANDED & READY FOR PAINT. (EXACT COLOR T.B.D.) ON 25 GA. 3 5/8" STL. CHANNEL FRAMINr. HI INr. PFR I ISr. MFr. SPFr:C +Q nn' A F F APPROVED BY _ (!i7 FI;�C 0EP 111' RIT SP:C �FLCG. N -SITE DAT l �� -210 I ALL FINISHES SHALL BE MIN. OF CLASS "C" RATED. EQUIPMENT SCHEDULE _0 1 - REACH IN FREEZER 2 - WORKTOP REFRIGERATOR 3 - COUNTERTOP WARMER 4 - 10 BURNER RANGE W_/_2_ OVENS ; 5 - DEEP FRYER W/ LG. EASKET = = 6 - REFRIGERATED WORK TOP 7 - REACH IN REFRIGERATOR 8 -1 COMP. SINK 9 - S/S WORK TABLE (6' -0 ") 10 - COLD BEVERAGE REFRIGERATOR 11 -SODA DISPENSER 12 - STRIP WARMER 13 - STEAM TABLE W16 WELLS 14 - COLD SANDWICH /SALAD UNIT 15 - 24"X 48" WIRE STORAGE SHELVES 16 - ICE MACHINE (30 ") 17 - 24" X 60" WIRE STORAGE SHELVES 18 - S/S DISH TABLE 19 - HI -TEMP SANITIZER 20 - S/S DISH TABLE SINK W /FAUCET & SPRAYER 21 - 3 -COMP. SINK 22 - SERVICE SINK 23 - 30 GALLON WATER HEATER 24 - GREASE LADEN HOOD SYSTEM #1, MIN. 6" OVERLAP. (DOCUMENTS BY OTHERS,SEE ATTACHED) ALL EQUIPMENT & COUNTERS /CABINETS DETERMINED BY FRANCHISEE AND /OR KITCHEN DESIGN CONSULTANT. CONTRACTOR & SUB - CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND UTILITY CONNECTIONS WITH CUT SHEETS OR MFG. RECOMENDATIONS PRIOR TO ANY WORK. DO NOT INSTALL PARTITIONS, CUT SLABS OR BRING UTILITIES TO AREA WITHOUT FIRST VERIFYING ALL REQUIREMENTS W /FRANCHISEE PROVIDED INFORMATION. IMPORTANT NOTES FOR GENERAL CONTRACTOR ' G C = REFERS TO GENERAL CONTRACTOR • K E C - REFERS TO KITCHEN EQUIPMENT CONTRACTOR 1- REFER TO FINAL SHOP DRAWINGS FOR VEN771AT70N SYSTEM AND FABRICATION 2- VERIFY WALL DIMENSIONS, CEILING HEIGHTS AND ENTRY PRIOR TO FABRICA71ON 3- REFER TO SPECIRCA77ONS AND CUT SHEETS FOR PERTINENT INFORMA7101V OF MANUFACTURED ITEMS 4- ROOF PENE7RATIONS FOR REMOTE REFRIGERATION SYSTEMS, INSTALLAT70N OF ROOF CURBS AND ROOF "JACKS" AND SEALING OF SAME WILL BE THE RESPONSIBILITY OF THE G C CURBS AND 'JACKS' SUPPLIED BY THE K E C 5- ROOF PENE7RATIONS FOR EXHAUST SY57EY AND SEALING OF SAME WILL BE THE RESPONSIBILITY OF THE G C 6- FIRE CHASE BY OTHERS - IF REQUIRED INTERIOR FINISH NOTES: • ALL INTERIOR FLOOR, WALL & CEILING FINISHES SHALL BE DETERMINED BY FRANCHISEE OR THEIR DESIGN CONSULTANT. (THIS INFORMATION NOT A PART OF "WHA" SERVICES.) • ALL MILLWORK & FURNITURE TO BE DETERMINED BY FRANCHISEE OR THEIR DESIGN CONSULTANT. (THIS INFORMATION NOT A PART OF "WHA" SERVICES.) AXIMUM OF Y2" DIFFERENCE IN LEVEL BETWEEN OPPOSITE SIDES OF _L EXIT DOORS IN ACCORDANCE WITH NFPA 101 5- 2.1.3.3 & THE ORIDA FIRE PREVENTION CODE. E AND /OR SMOKE SEPARATION WALLS AND PARTITIONS MUST BE NTIFIED WITH STENCILED SIGN AS PER FBC 704.2.1.4 & THE FFPC. tE ALARM SYSTEM NOT REQUIRED FOR OCCUPANCY = 28 PEOPLE. R NFPA 101 13.3.4.1, ASSEMBLY OCCUPANCIES OF MORE THAN 300 QUIRE AN APPROVED FIRE ALARM SYSTEM. PROVIDE SIGN STATING THE MAXIMUM SEATING CAPACITY, CONSPICUOUSLY POSTED IN DINING AREA AS PER THE FFPC. SIGNS SHOULD STATE THE FOLLOWING: "SEATING CAPACITY BY MORE THAN 78 PERSONS IS DANGEROUS AND UNLAWFUL." OCCUPANT LOAD:.. per FFPC Table 7.3.1.2 GROSS AREA = 2116.59 S.F. MAX. AREA FOR SMALL ASSEMBLY: DINING AREA: 1073.50 S.F. / 15 = 71.57 PEOPLE BENCH SEATING (WAITING AREA)10 LINEAR FT. PER BENCH /18 LIN. IN./PERSON = 6.66 PEOPLE = 7 PEOPLE DINING AREA: TOTAL ALLOWED = 76.23 PEOPLE ACTUAL NUMBER OF SEATS = 68.00 PEOPLE KITCHEN, PREPARATION, CUSTOMER SERVICE AREA & RESTROOM AREA: 1043.09 S.F. / 100 =10.43 PEOPLE TOTAL ALLOWED = 88.66 PEOPLE = 89 PEOPLE SHT. A -3 FOR EXTERIOR ELEVATION AND TYPICAL PARTITION DETAIL william hamilton arthur architect Inc. 800 douglas entrance suite 303 coral gables, florida. 33134 (305)443 -3100 fax (305)441 -7960 license no. 2282 DRAWN BY: ��_ �,4 t J_ {n Uj F- Q 0 LU Z cn o zQ -� REVISION DATIEF(S) Q 07.08.05 0 PRO.I. NO: DATE: 05-25 04.23.05 SHEET NO.: A -1 3 OF 13 J_ {n Uj F- Q 0 LU Z cn o zQ I- rUj V W W _I J z I.I.I _ m � U Q O� U O w LL O o w w Cn w °_° cW G REVISION DATIEF(S) Q 07.08.05 0 PRO.I. NO: DATE: 05-25 04.23.05 SHEET NO.: A -1 3 OF 13 Z 9 I- U) W z Q U) U) U w X Q w °_° cW G � U) O 0 z z z w �MJ o¢z W nom Z UU_ m w CD 7 O w Q a a. N Q w REVISION DATIEF(S) Q 07.08.05 0 PRO.I. NO: DATE: 05-25 04.23.05 SHEET NO.: A -1 3 OF 13