Loading...
05-1059-0060 0 r E 0 12 N I LO 0 0 N cd N o Z H o d IL n N Ln 0 0 o z 0 N J 0, 3 ItU N I I CL c 0 N c o V .% d o c D o IL N V d 0 CL 0 U N E z° c, 0 0 GAS PIPING NOTES: 1. GAS PIPE SIZES BASED ON PRESSURE DROP OF 0.5, WATER COL. GAS SPECIFIC GRAVITY OF 0.6 AND SCHEDULE 40 BLACK STEEL PIPE 4.00 W.C. MINIMUM PRESSURE AND 14.00 W.C. MAXIMUM PRESSURE. 2. GAS PIPING SHALL BE INSTALLED IN ACCORDANCE WITH NFPA -54 AND THE STANDARD GAS CODE. (1991) 3. THE INSTALLATION SHALL BE FOR PROPANE GAS AND BE INSTALLED BY A LICENSED SUB - CONTRACTOR. (VERIFY SUPPLIER) 4. A NEW GAS METER AND PRESSURE REGULATOR SHALL BE PROVIDED BY THE UTILITY COMPANY. 5. GAS PIPING SHALL BE SCHEDULE 40 SEAMLESS BLACK STEEL PIPE AND BLACK IRON FITTINGS. GAS PIPING OUTSIDE THE BUILDING SHALL BE PAINTED WITH BLACK 'RUSTOLEUM' PAINT. 6. GAS PIPING SHALL BE PROVIDED WITH DRIP POCKETS AND DIRT LEGS IN ACCORDANCE WITH CODE REQUIREMENTS. 7. A GAS COCK AND QUICK- RELEASE FITTING SHALL BE PROVIDED AT ALL GAS APPLIANCES W/ CHAIN RESTRAINTS. 8. PROVIDE AN ACCESSIBLE MECHANICALLY OPERATED UL APPROVED GAS VALVE BELOW CEILING FOR EMERGENCY SHUT -OFF. COORDINATE WITH FIRE PROJECT SYSTEM. GAS VALVE SHALL BE MANUALLY RE -SET. 9. SEE SEPARATE HOOD DRAWINGS AND HOOD DETAILS FROM HOOD MANUFACTURER. 10. ALL GAS VALVES WILL BE INSTALLED IN ACCESSIBLE LOCATION. c- I C 1 GAS METER & PRESSURE SET BY LOCAL GAS COMPANY GAS PLAN 1/4" = 1' -0" 1/2" GAS LINE UP WALL ,ol „oil Ir PROVIDE MECHANICAL SHOCK ABSORBER FOR SOLENOID VALVE FOR ALL WATER PROOF CONNECTIONS AS PER FBC 604.9 LONGEST RUN OF GAS LINE cqs TO METER IS 35.18' \ TOTAL BTU = 339,500 U) S• \ G'. 1 1/2" GAS LINE '9S > G' 1 1/2" '�S LINE MANUAL SOV 2" BALL VALVE, \ BELOW CEILING MASTER MAIN SHUT -OFF C•9S. GAS SHUT OFF VALVE c� INTERLOCKED WITH HOOD tDn SUPPRESION SYSTEM TO GAS P. R. D C,9 SHUT OFF UPON ACTIVATION �— SVO - 8.75' — I �- I, 1560' � s 1/2" GAS BALL F I R A ' I FRYER FOR BALL TO _ _ 3L4_GAS BAIL FOR A HOT FOOD /STEAM 6- BURNER RANGE /GRIDDLE 120K BTU's !I TABLE 17.5K BTU'S W /OVEN 202K BTU'S I I I I i l i J ii I I, _ I _ �.�_ FYI 10.00' EXIST. > / GAS METER >,,{ G4 3" LINE DOWN C)/— Cd D 10.00' DRIP LEG c� SHUT OFF VALVE D 0 D 1 1/2" 1/2" GAS BALL LINE FOR A HOT FOOD /STEAM o TABLE 17.5K N BTU'S DRIP LE Sb� 3/4" GAS BALL \ S FOR A 6- BURNER S, 6O• RANGE /GRIDDLE bS W /OVEN 202K \ BTU'S DRIP LEG Sb� 3/4" GAS BALL J TO FRYER JJ� 120K BTU's GAS RISER N.T.S. NOTE:_ CONTRACTOR; SHALL VERIFY MOUNTING HEIGHTS OF GAS_ E( UIPME:N r_ FOR STUB —UP's PRIOR TO GAS PIPING ROUGH —IN. SEE ADDITIONAL GAS NOTES, THIS SHEET. NOTE: GAS METER SHOWN IS FOR DIAGRAMATIC PURPOSES ONLY AND IS NOT THE ACTUAL LOCATION OF METER AT SITE. SEE SITE PLAN FOR A MORE ACURATE DESCRIPTION OF METER LOCATION. CONTRACTOR SHALL FIELD VERIFY PRECISE LOCATION PRIOR TO PERFORMING HIS /HER WORK. PROVIDE BELOW CEILING MASTER GAS SHUT OFF VALVE INTERLOCKED WITH HOOD SUPPRESION SYSTEM TO SHUT OFF UPON ACTIVATION PROVIDE SHUT -OFF VALVE ® EACH GAS LINE DOWN william hamilton arthur architect inc. 800 douglas entrance suite 303 coral gables, florida, 33134 (3051443 -3100 fax (305)441 -7960 license no. 2282 w J V) Lij Cn Cn Q C� Cn z� Q 0 �z �o Qz CD Q DRAWN 8 :- ,4 M.M.H. - SEAL`' ., 9 D U W z W w J V) Lij Cn Cn Q C� Cn z� Q 0 �z �o Qz CD Q REVISION DATE(S) A11.14.05 0 0 PR 5J -250 I 04 23.05 SHEET NO.: P 3 12 OF 13 z 9 D U W z W W U Z) Q � w m W a O ° LLJ / Q Z _ cr_ N Ld F— F- JM — O Z O a- D j 0 � W O� m W X CL CL Y / Q 0 25LOU REVISION DATE(S) A11.14.05 0 0 PR 5J -250 I 04 23.05 SHEET NO.: P 3 12 OF 13