Loading...
05-1059-0040 v 0 0 a E N I 0 0 N 06 N M Z IL E 0 o O a O N E \ LO `a o 0 N N 0 o� Z �. aiii J o, M 3 v a� J I O� bi (n l Q. I L I V) W ` � o C o ` D 0 0 = u Cr - U u C Q) 31 o V c L o () a 0 IL v 0 v O o Z a` N U a� 0 2 CL L) - N V v E c Z c U o / � N 44.34 KVA 67.20 KW / 360 = 190.00 AMPS 2 2.8 6 KVA EXISTING COMPRESSORS. ELECTRICAL SCHEDULE PANEL "A" TYP. DUPLEX RECEPTACLE TYPE SQ. D / 10,000 A.I.C. MAINS MLO/ 225 AMP MOUNT SURFACE BUS 225 AMP LOC. SEE PLAN VOLTS: 120/208 CIRC. POLE KVA DESCRIPTION WIRE COND. CIRC. POLE KVA DESCRIPTION WIRE COND. 1 1/20 1.50 REACH IN FREEZER 2-#12 1/2- 2 1/20 1.30 WORKTOP REFRIGERATOR 2-#12 1/2" 3 1/20 1.20 COUNTERTOP WARMER 2 - #12 1/2" 4 1/20 1.30 REACH -IN REFRIGERATOR 2 - #12 1/2 r' 5 1/20 1.50 SL. DOOR REFRIG. 2-#12 1/2- 6 1/20 1.50 REACH IN REFRIGERATOR 2-#12 1/2" 7 1/20 1,20 HOT FOOD WELL 2 - #12 1/2" 8 2/30 2.20 HI -TEMP SANITIZER 2 - #12 1/2" 2-#12 1/21p 9 1/20 .40 SOUP WELL 2-#12 1/2-1 10 11 3/100 26.30 SUB -PANEL "B" #3 2" 12 1/20 1.50 ICE MACHINE 2 - #12 1/2" 13 14 1/20 1.50 SANDWICH UNIT (MEGA) 2 - #12 1/2 Is 15 16 1/20 1,20 INFRARED FOOD WARME 2 -# 12 1/2" 17 1/20 .75 SODA DISPENSERS 2 - #12 1/2" 18 1/20 1.50 ELECTRIC CHEESEMELTE 2 -# 12 1/2" 19 1/20 1.50 SMALL APPLIANCE 2-#12 1/2" 20 1/20 1.50 SMALL APPLIANCE 2 - #12 1/2's 21 1/20 1.50 SMALL APPLIANCE 2-#12 1/2" 22 1/20 1.50 SMALL APPLIANCE 2-#12 1/2" 23 1/20 .25 P.O.S. 2-#12 1/219 24 1/20 ,54 WINDOW OUTLET 2-#12 1/20' 25 1/20 .50 GENERAL USE 2-#12 1/299 26 1/20 1.20 EXTERIOR SIGN 2-#12 1/2" 27 1/20 .20 PHONE SYSTEM 2-#12 1/2" 28 1/20 1.20 WATER FEATURE 2-#12 1/2's 29 1/20 .50 MUSIC SYSTEM 2-#12 1/2" 30 1/20 .86 BATHROOM LIGHTS 2-#12 1/211 31 1/20 1.28 LIGHTING 2 - #12 1/2" 32 1/20 1.12 KITCHEN LIGHTS 2 - #12 1/2" 33 1/20 1.28 LIGHTING 2 - #12 1/2" 34 1/20 .36 NIGHT LIGHTING 2 - #12 1/2" 35 1/20 1.44 LIGHTING 2-#12 1/2" 36 1/20 .50 HOOD LIGHTS 2-#12 1/2" 37 1/20 1.44 LIGHTING 2-#12 1/2- 38 1/20 .80 LIGHTING 2-#12 1/2" 39 1/20 1.60 LIGHTING 2 - #12 1/2" 40 1/20 1.28 LIGHTING 2 - #12 1/2" 41 - - BLANK - - 42 - - BLANK _ - 44.34 KVA 67.20 KW / 360 = 190.00 AMPS 2 2.8 6 KVA EXISTING COMPRESSORS. 13.80 KVA 12.50 KVA 26.30 KVA / 360 = 70.00 AMPS THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CONNECTIONS & METHODOLOGY FROM METER TO NEW PANEL AS INDICATED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTING AVAILABLE VOLTAGE VERSUS WHAT IS PROPOSED PRIOR TO FINALIZED BID TO FRANCHISEE. SEE FRANCHISEE PROVIDED CUT - SHEETS FOR ALL EQUIPMENT AND HOOD SYSTEM PRIOR TO SUBMITTING BID. /-- /,-I ­N WTR. HTR. B -14,16 +18" ELEC. FLOOR PLAN 1/4" = 1 P -01' ELECTRICAL LEGEND ELECTRICAL SCHEDULE PANEL "B" (SUB - PANEL) TYP. DUPLEX RECEPTACLE TYPE SQ. D / 10,000 A.I.C. MAINS M.C.B. MOUNT SURFACE MOUNTED BUS 150 AMP LOC. SEE PLAN VOLTS: 120/208 CIRC. POLE KVA DESCRIPTION WIRE COND. CIRC. POLE KVA DESCRIPTION WIRE COND. 1 3/60 7.50 H.V.A.C. SYSTEM #1 4 TONS (NEW SYSTEM /REPLACEMENT) W/ 7.5 KW HT. STRIP #6 1 vp 2 3/60 9.50 H.V.A.C. SYSTEM #2 6.0 TONS (NEW SYSTEM /REPLACEMENT) W/ 7.9 KW HT. STRIP #6 110 3 4 5 6 7 3/20 2.50 HOOD SYSTEM EF# 1 #12 1/2 to 8 1/20 1.00 ANSUL SYSTEM #1 2-#12 1/2" 9 10 1/20 1.00 SPARE 2-#12 1/219 11 12 1/20 1.00 SPARE - #12 1/2" 13 3/30 3.80 HOOD SYSTEM SF #1, 1.5 hp #12 1/2" 14 2/20 3,80 ELEC. WTR. HTR. 120G. #12 1/2" 15 16 17 18 -- -- BLANK - -- -- 19 -- -- -- -- -- -- BLANK BLANK BLANK __ -- -- 20 -- -- BLANK - -- -- 21 22 -- -- BLANK - -- -- 23 24 -- -- BLANK - -- -- 13.80 KVA 12.50 KVA 26.30 KVA / 360 = 70.00 AMPS THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CONNECTIONS & METHODOLOGY FROM METER TO NEW PANEL AS INDICATED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTING AVAILABLE VOLTAGE VERSUS WHAT IS PROPOSED PRIOR TO FINALIZED BID TO FRANCHISEE. SEE FRANCHISEE PROVIDED CUT - SHEETS FOR ALL EQUIPMENT AND HOOD SYSTEM PRIOR TO SUBMITTING BID. /-- /,-I ­N WTR. HTR. B -14,16 +18" ELEC. FLOOR PLAN 1/4" = 1 P -01' ELECTRICAL LEGEND DATE: TYP. DUPLEX RECEPTACLE 04.23.05 TYP. QUADPLEX RECEPTACLE NO.: TYP. DUPLEX CEILING OUTLET a TYP. PHONE OUTLET zry TYP. PHONE /DATA OUTLET OJUNCTION BOX GFI DENOTES GROUND FAULT INTERRUPTER. WP DENOTES WEATHERPROOF. X 10' GROUND RODSs ELECTRICAL-- NOTES. � - 1. ALL WORK SHALL BE DC-NE IN ACCnF�DANc;E WI_TA __ME LATEST APPROVED EDITION OF THE FLORIDA BUILDING CODE. THE- NATIONAL kL�C- TRICAC CODE, NFPA AND ANY APPLICABLE LOCAL CODES AND ORDINANCES. -- - 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS UNLESS OTHERWISE NOTED. 3. THE ELECTRICAL CONTRACTOR SHALL ESE RFSPONSIaE FOR COMMUNICATION WITH THE OWNER'S PERSONNEL TO REVIEW CON RACr DOCJMEn i S PRIOR TO INSTALLATION. 4. THE OWNER WILL NOT BE HELD LIABLE FOR FIELD CHANGES THAT MAY ARISE FROM CONTRACTOR ERROR OR OMISSION OF MATERIALS OR WORKMANSHIP IN TRADE PERFORMANCE. 5. IN GENERAL, PLANS AND DETAILS ARE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED COORDINATE ALL ELECTRICAL WORK WITH PLUMBING, HVAC AND FIRE SUPPRESSION WORK SO AS NOT TO CONFLICT IN LOCATION OR PERFORMANCE OF OTHER SYSTEMS 6. NECESSARY, OBVIOUSLY REQUIRED ELECTRICAL ITEMS THAT ARE NOT SHOWN ON THE DRAWINGS DOES NOT RELIEVE THE CONTRACTOR OF THEIR RESPONSIBILITY TO INSTALL A COMPLETE OPERATING AND SAFE ELECTRICAL SYSTEM. 7. ELECTRICAL CONTRACTOR SHALL KEEP A MASTER SET OF BLUE LINES THAT ARE TO BE MARKED UP TO REFLECT "AS BUILT" CONDITIONS ON A DAILY BASIS. THESE "AS BUILT" MARK -UPS MAY BE REVIEWED BY THE ARCHITECT, ENGINEER, OR OWNER'S REPRESENTATIVE, AT THEIR REQUEST AND WITHOUT PRIOR NOTIFICATION. THESE "AS BUILT" DRAWINGS WILL BE TURNED OVER TO THE OWNER AT THE CONCLUSION OF THE PROJECT. 8. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL NECESSARY FEES AND POWER COMPANY CHARGES IN HIS BID. 9. CONTRACTOR TO VISIT THE SITE AND ALLOW FOR ALL EXISTING CONDITIONS IN HIS BID. 10. THOROUGHLY REVIEW FINAL LOCATION, TYPE, MOUNTING HEIGHT AND CONTROL OF ALL DEVICES PRIOR TO ROUGH IN. 11. COORDINATE FINAL INSTALLATION REQUIREMENTS WITH PROPER AUTHORITIES. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL INSPECTIONS AND CERTIFICATIONS THAT MAY BE REQUIRED, DURING AND UPON COMPLETION OF HIS WORK. 13. ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE EFFECTIVELY GROUNDED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE REQUIREMENTS. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN. 14, ALL BRANCH CIRCUIT CONDUCTORS SHALL BE MIN 75d c /THHW /THWN COPPER MINIMUM SIZE SHALL BE No. 12 RUN IN APPROVED METAL RACEWAY. 15. FOR 20 AMP BRANCH CIRCUITS GREATER THAN 10OFT IN LENGTH ONE WAY, UP TO 200 FT. USE No. 10 WIRE OVER 200 FT. USE No. 8 WIRE. INCREASE CONDUIT SIZE AS REQUIRED FOR THE LARGER CONDUCTORS THIS SUPERSEDES WIRE SIZES CALLED FOR ON THE DRAWINGS. 16. RIGID CONDUIT SHALL BE GALVANIZED STEEL HOT DIPPED OR SHERADIZED STEEL ZINC COATED AND SHALL BEAR THE UNDERWRITER'S LABORATORY LABEL. CUT THREADS SHALL BE FULL DIE CUT AND PROTECTED FROM RUST, 17. RIGID CONDUIT SHALL BE USED WHERE INSTALLATION IS BELOW GRADE, IN CONCRETE, SLABS, EXPOSED TO WEATHER IN DAMP LOCATIONS, IN EXTERIOR WALLS, IN CONCRETE BLOCK WALLS INTERIOR OR EXTERIOR AND IN CONNECTION TO PANEL BOARDS AND CABINETS. 18. RIGID CONDUIT ENTERING AND LEAVING PANEL BOARDS, CABINETS AND OUTLET BOXES, SHALL BE PROVIDED WITH LOCKNUTS ON BOTH SIDES OF SUCH DEVICES AND DRIVEN TIGHT TO MAINTAIN POSITIVE ELECTRICAL AND MECHANICAL CONTINUITY THROUGH THE CONDUIT SYSTEM, INSULATED BUSHINGS SHALL BE INSTALLED INSIDE THE TERMINATIONS MINIMUM TRADE SIZE OF RIGID CONDUIT SHALL BE HALF INCH. 19. INSTALLATION IN GENERAL, ALL RACEWAYS SHALL RUN CONCEALED WITHIN WALLS, CEILINGS, OR FLOORS UNLESS OTHERWISE INDICATED OR SPECIFIED. WHERE IMPOSSIBLE TO RUN CONCEALED, A SURFACE MOUNTED METAL RACEWAY ADEQUATELY PROTECTED AND SUPPORTED MAY BE USED WITH WRITTEN AUTHORITY OF ARCHITECT AND OWNER. 20. ELECTRICAL METALLIC TUBING AS DEFINED IN THE N.E.C. MAYBE USED ABOVE CEILINGS AND IN PARTITION WALLS. CHANGES FROM RIGID CONDUIT TO E.M.T. SHALL BE MADE AT A JUNCTION BOX MINIMUM TRADE SIZE OF E.M.T. WHERE CONCEALED IN PARTITION WALLS OR ABOVE PLASTERED CEILINGS OR OTHERWISE NOT ACCESSIBLE SHALL BE THREE HALF INCH (1/2 ") ONLY COMPRESSION TYPE CONNECTORS OR COUPLINGS WILL BE USED. 21. TYPE MC CABLE MAY BE USED AS PER CODE. 22. USE SEAL OFF'S FOR ALL PENETRATIONS OF COOLER. 23. ALL CIRCUITS SHALL HAVE GREEN BONDING GROUND PER CODE. THE CIRCUITRY ON THESE PLANS ARE FOR THE SOLE PURPOSE OF BALANCING THE PANEL LOADS. IT IS NOT INTENDED NOR EXPECTED OF THE ELECTRICIAN TO FOLLOW THIS SPECIFIC LAYOUT IN THE PROCESS OF WIRING THIS PROJECT. IT IS HOWEVER, THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR OF RECORD, TO PROVIDE AND TO SUBMIT TO THE ARCHITECT AND LANDLORD, A COMPLETE MARKED -UP SET OF 'AS- BUILT' PRINTS OF ANY CHANGES, MODIFICATIONS OR DEVIATIONS FROM THIS PLAN IN ANY FORM. THE CONDUIT FOR RECEPTACLES LOCATED AT THE COUNTER WILL BE RUN THROUGH THE STUDS. EXISTING LINE GUTTER ONEW MTR. AND DISC. FOR NEW EQUIPMENT 225 225 s 1/0 GROUND ELECTRICAL RISER DIA. I � (2) 5/8" DRIVEN GROUND RODS W/ rW RnNn (4) 4/0 M IN 2 )�" CON. William hamilton arthur architect Inc. 800 douglas entrance suite 303 coral gables, florida, 33134 (305)443 -3100 fax (3051441 -7960 license no. 2282 DRAWN BY: U M. M., H. 1 i �w c• REVISION DATE(S) A11.14.05 A 0 PROJ. NO: DATE: 05 -25 04.23.05 W NO.: E-1 zry Q (.%) �z NW L.L 0 Ld O w w 0 U Ld Q LJ_ --I W W Q W L U � � O_ 0 �oz Z Q E2 , N W p F- W NNZ Of Of Z 0 of LL_I 0 w U z -j LLJ V) Q w V) REVISION DATE(S) A11.14.05 A 0 PROJ. NO: DATE: 05 -25 04.23.05 z NO.: E-1 8OF13 U NW L.L z Q w 0 U Ld Q Xm W W a O_ in < Z Q E2 , N W p F- JU] NNZ Of Of Z 0 of U LLI N L� m LLI of W O - 00 Q n I.r)5LOU REVISION DATE(S) A11.14.05 A 0 PROJ. NO: DATE: 05 -25 04.23.05 SHEET NO.: E-1 8OF13 ti "may.