Loading...
07-638-074System No. WL1001 (Formerly Sytem No. 147) F Ratings -1,2,3 and 4 Hr (See Items 2 and 3) T Rating - 0,1,2,3, and 4 Hr (See Item 3) L Ratring At Ambient -less than 1 cfm /SQ. FT. L Rating At 400 F -less than 1 CFM /sq ft V V V V W• 4 G V Oak"* V V e • CKT. BKR. • V u V V U • V VVV V A W V 4 V Q1 V • V DINNING BOOTH LIGHTS G • Y V • V Y• Y ' Y V V 3 V V V V V V GUY •YV i V u VuuV V Vu Ui• INC. 20/1 P1 "a so* V VV V VVU V Y • • V • 4 V • W • V U 4 V V • Y Y V V V•V A U V V V V ' • 4uV YV V V • Y Y i 9 • • U • • VVV 800 VVV V Y 20/1 V Y V V V 315 A L.V. 20/1 C 11 Y • DINING TABLE LIGHTS V B L.V. V Y Y 12 Y V • V 4 V 4 i V Y V 4 V 4 ur u V Y V u U V W �a V 11AX. ANNULAR SPACE IS 1/4" "OR CONDUIT UP TO 4" DIAMETER PER SYS. NO. WL 1001, U.L )IRECTORY, VOL II, 1997 ED. ;CONDUITS WILL NOT EXCEED 4 ") to A 0991 N A-A 1. Well Assembly -The 1,2,3 or 4 hr fire- -rated gypsum wallboard /stud well assembly shall be constructed of the materials and in the manner described in the Individual U300 or U400 Series Wall or Partition Designs In the UL Fire Resistance Directory and shall Include the following construction features: A. Studs -Well framing may consist of either wood studs (max 2 h fire rated assemblies) or steel channel studs. Wood studs consist of nom 2 by 4 in. lumber spaced 16 In. OC with nom 2 by 4 in. lumber end plates and cross braces. Steel studs to be min 3 -5/8 in. wide by 1 -318 in. deep channels spaced max 24 in. OC. B. Wallboard, Gypsum* -Nom 1/2 or 5/8 in, thick, 4 ft. wide with square or tapered e4les. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory, Max diem of opening is 13-1/2 in. 2. Pip• or Conduit -Nom 12 In. diam (or smaller) Schedule 10 (or heavier) steel pipe, nom 12 in. diam or smaller) service weight (or heavier) cast iron sell pipe, nom 12 in. diam (or smaller) Class 50 or heavier)) ductile iron pressure pipe, nom 6 in. diem (or smaller) steel conduit, nom 4 in. diam or smaller steel electrical metallic tubing, nom 6 in. diem (or smeller) Type L or (or heavier) copper tubing or nom 1 in. dlem (or smaller) flexible steel conduit. When copper pipe is used, max F rating of firestop system (item 3) is 2 h. Steel pipes or conduits larger than nom 4 in. diam may only be used in wells constructed using stool channel studs. A max of one pipe or conduit is permitted in the firestop system. Pipe or conduit to be installed near center of stud cavity width and to be rigidly supported on both sides of wall assembly. 3. Fill, Void or Cavity Materiel + - Caulk -Caulk fill material installed to completely fill annular space between pip• or conduit end gypsum wallboard and with a min 1/4 diam bead if caulk applied to perimeter of pipe or conduit at Its egress from the well. Caulk installed symmetrically on both sides of well assembly. The hourly F rating of the firestop system is dependent upon the hourly fire rating of the wall assembly in which it is Installed, as shown in the following table. The hourly T rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which it is installed, as tabulated below: mm 0100000 • ENCLOSURE DIMENSION: 24 "W X 48 "H X 5.75 "D • • 0 o, PANEL "D" 18 - DIMMER MODULES DIMMER CABINET 9 MUNSON P1 �_j MHMMMI _, ......e p 8 e"h MASTER CONTROLLER "MSC12" FITS INTO A 4 GANG RACO # 698 SWITCH BOX • (: 4/C -- #22 AWG SHIELDED CABLE IN 1/2" CONDUIT 1 • • COVER DIMENSION: 26 "W X 50 "H DIMMING SYSTEM CONTROL DETAIL NO SCALE GENERAL NOTES: 1. INFORMATION SHOWN ON THIS DETAIL IS DIAGRAMMATIC ONLY. VERIFY EXACT PART NUMBER OF EACH COMPONENT AND ALL NECESSARY MATERIALS AS REQUIRED AN OPERABLE MARLIN CONTROLS DIMMING SYSTEM WITH MANUFACTURER PRIOR TO BID. CONTACT MOE CHIGANI WITH MARLIN CONTROLS AT 2. 120/208 VAC, 3 FOR EC 4 IWIRESU M.LOT 3. RUN SEPARATE NEUTRAL PER CIRCUIT TO THE DIMMER CABINET, 4. LOW - VOLTAGE WIRING SHALL BE 4/C -22 AWG SHIELDED CABLE (#CVA- 220704) IN 3/4" CONDUIT. 5. PANEL 'D' IS PROVIDED BY CARRABBA'S. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MARLIN CONTROLS, INC. FOR THE CORRECT AMOUNT OF CIRCUIT BREAKERS. PROVIDE PANEL 'D' SCHEDULE AND NOTIFY MARLIN CONTROLS, INC. AT LEAST THREE (3) WEEKS PRIOR TO ROUGH -IN FOR ORDER. GENERAL CONTRACTOR SHALL COORDINATE WITH MARLIN CONTROL INC. FOR DELIVERY OF DIMMER CONTROL SYSTEM. ALL CONNECTIONS TO AND MOUNTING OF PANEL 'D' SHALL BE BY THE ELECTRICAL CONTRACTOR. ■ a- A. a-� A. ON -OFF PER OWNER N N N N N N N N H TO TIME C BLDG, LIGHTS CLOCK #1 CONTACTOR #1 9 POLE CONTACTOR, SIEMENS #LEN01CO09120A WITH 120 VOLT COIL OR APPROVED EQUAL W W W W W W W W W -K i N Ifs N N N N N 8WK� W ON -OFF PER OWNER N H _X TO TIME C 111!19. SIGNAGE CLOCK #2 N - - - - CONTACTOR #3 6 POLE CONTACTOR, SIEMENS #LEN01CO06120A WITH 120 VOLT v) COIL OR APPROVED EQUAL 9 W W W W W a- (n � V) LIGHTING CONTROL DIAGRAMS NO SCALE LIGHTING CONTROL DIAGRAM NOTES: 1. LOADS TO BE AUTOMATICALLY CONTROLLED, INCLUDE ALL EXTERIOR BUILDING SIGNS. 2. TIME CLOCKS SHALL BE PARAGON 101, 120V., 24 HOUR, SINGLE POLE, SINGLE THROW 40 AMP PER POLE AT 120V. RATED, WITH 16 HOURS OF CARRYOVER TIME. 3. LIGHTING CONTACTORS SHALL BE ELECTRICALLY HELD TYPE, 120V. COIL CONTROL, ALLOY DOUBLE BREAK 250 VOLT RATED CONTACTS, HEAVY DUTY AND U.L LISTED. (SHALL BE COMPATIBLE WITH TIME CLOCK) 4. SIGN CIRCUITS ARE 30A. PROVIDE CONTACTOR RATING TO EQUAL OR EXCEED. DIMMER PANEL SCHEDULE "D" 18DIMMERS BY MARLIN CONTROLS, DALLAS. TEXAS RATED 10,000 A.I.C. 100 AMP, M.L.O. 120/208 VAC, 3PH, 4 WIRES FLUSH MOUNTED CKT No. CHANNEL No. AREA CONTROLLED /SERVED WATTS PHASE LOAD TYPE CKT. BKR. FIXTURE TYPE 1 4 BAR BOOTH LIGHTS 150 A INC. 20/1 Q1 2 6 DINNING BOOTH LIGHTS 450 B INC. 20/1 Q1 3 1 BAR DOWNLIGHTS 260 C INC. 20/1 F2 4 2 PASTA TRACK 600 A INC. 20/1 P1 5 3 DINING WALL WASH 245 B L.V. 20/1 C3 6 7 DINING DOWNLIGHTS 1000 C INC. 20/1 F 7 7 DINING DOWNLIGHTS 1050 A INC. 20/1 F 8 9 DINING TABLE LIGHTS 315 B L.V. 20/1 C 9 5 BAR DOWNLIGHTS 800 C INC. 20/1 F 10 9 DINING TABLE LIGHTS 315 A L.V. 20/1 C 11 9 DINING TABLE LIGHTS 315 B L.V. 20/1 C 12 3 DINING WALL WASH 245 C L.V. 20/1 C3 13 9 DINING TABLE LIGHTS 175 A L.V. 20/1 C 14 11 BAR WALL WASH 280 B L.V. 20/1 C3 15 -- SPACE -- C - 20/1 - 16 10 BAR PENDANTS 280 A L.V. 20/1 H 17 8 BAR TABLE LIGHTS 315 B L.V. 20/1 C 18 2 PASSAGE TRACK 550 C INC. 1 20/1 P1 19 NON -DIM EMERG. LTG. CIRCUIT 800 A INC. 20/1 F,G,G2,X 20 NON -DIM CIRCUIT BACK BAR 700 B INC. 20/1 61 21 NON -DIM CIRCUIT BACK BAR 400 C INC. 20/1 62 (ELECTRONIC) (ELECTRONIC) (ELECTRONIC) (ELECTRONIC) (ELECTRONIC) (ELECTRONIC) (ELECTRONIC) (ELECTRONIC) DIMMING SYSTEM CONTROL DETAIL GENERAL NOTES 1. INFORMATION SHOWN ON THIS DETAIL IS DIAGRAMMATIC ONLY. VERIFY EXACT PART NUMBER OF EACH COMPONENT AND ALL NECESSARY MATERIALS AS REQUIRED TO COMPLETE AN OPERABLE MARLIN CONTROLS DIMMING SYSTEM WITH MANUFACTURER PRIOR TO DID. CONTACT MOE CHIGANI WITH MARLIN CONTROLS AT (214) 553 -5700 FOR TECHNICAL SUPPORT. 2. RUN SEPARATE NEUTRAL PER CIRCUIT TO THE DIMMER CABINET. 3 IN 1/2- WIRING CONDUIT CIRCUIT LSHALL BE 2 #12, 1 #12 E.G. IN 1/2" CONDUIT, FOR WIRING OVER 70' -0" 2 #10, 1 #10 E.G. © LOCKED "ON" CIRCUIT BREAKER NOTE: PANEL "D" IS SHIPPED WITH PRE -SET DIP SWITCHES. EC MUST WIRE PANEL AS INDICATED ABOVE. DO NQT GROUP ELECTRIC LOW VOLTAGE CIRCUITS IN SAME CONDUIT WITH ANY OTHER LOADS. EDH- -1,2,3 AHU -1,2,3 CU -1,2,3 (TYP.) (TYP.) (TYP. ) 30/3/15 D.E. 30/3/4 D.E. 60/3/40 D.E. (60OV) (600V) ,� (60OV) J 40A.3P,480V 3 #12, 1 #12 E.G. 3 #8, 1 #10 E.G. IN 1/2- C. IN 3/4" C. 20A,3P,480V EDH -4 AHU -4 CU -4 30/3/7.5 D.E. 30/3/6 D.E. 60/3/50 D.E. (60OV) (60OV) WF1 (60OV) J 50A,3P,480V 3 #12, 1 #12 E.G. 3#6, 1 #10 E.G. IN 1/2- C. IN 3/4" C. 15A,3P,480V EDH- -5 AMU -5 CU -5 30/3/7.5 D.E. 30/3/4.5 D.E. 60/3/40 D.E. (60OV) (60OV) ,� (600V) J 40A,3P,480V 3 #12, 1 #12 E.G. 3 #8, 1 #10 E.G. IN 1/2* C. IN 3/4" C. 15A,3P,480V NOTES: 1. VERIFY NAMEPLATE RATINGS, LOCATIONS, AND POINT OF POWER CONNECTIONS PRIOR TO START OF PROJECT. 2. DO NOT LOCATE DISCONNECT SWITCHES OVER UNIT ACESS PANELS, 3. PROVIDE A 3/4" EMPTY CONDUIT THROUGH INACESSIBLE LOCATIONS (i.e.,WALLS, UNDER SLAB) FOR CONTROL WIRING. COORDINATE WITH MECHANICAL PLANS. 4. ELECTRICAL DISCONNECT SWITCHES, CONDUIT AND WIRE SHOWN ARE SIZED, AS PER THE MANUFACTURER AND MODEL NUMBER LISTED ON MECHANICAL PLANS. IF THERE IS AN EQUAL MANUFACTURER, OR OTHER MANUFACTURER PROVIDED, THE MECHANICAL/ GENERAL CONTRACTOR SHALL BARE ANY ADDITIONAL COST INCURRED IF THE ELECTRICAL IS NOT EQUAL TO SPECIFICATIONS. 5. ELECTRICAL CONTRACTOR SHALL INSTALL ALL STARTERS FURNISHED BY MECHANICAL CONTRACTOR AND SHALL MAKE ALL REQUIRED CONNECTIONS UNLESS STARTERS ARE SPECIFICALLY NOTED ON MECHANICAL PLANS TO BE FACTORY INSTALLED (SEE NOTE 4). MECH. EQUIP. POWER WIRING DETAILS N.T.S. UNI STAR MSC12 SEE NOTE #1 CEILING CEILING FAN FANS LIGHTS ON /OFF NOTE 2 1 ONLY BAR BAR BAR TRELLIS LIGHTS LIGHTS LIGHTS ON /OFF NOTE 2 NOTE 2 NOTE 2 ONLY 6 " 6 "� uri FLOOR DiMMER DETAIL 1. DIMMER CABINET MASTER CONTROLLER "MSC12" IN 4 GANG RACO #698 SWITCH BOX. RUN 4 #22 SHIELDED CABLE FROM CONTROLLER TO DIMMER PANEL. 2. DIMMER TO BE LEVITON INCANDESCENT SLIDE DIMMER WITH LED 1000VA CAT. INI10 -1LW (WHITE). RUN SEPARATE NEUTRAL FOR THE CIRCUIT. Harold Hart & Associates, Inc. CONSULTING ENGINEERS 4201 West Gray Street : Tamps, Florida 33609 Telephone: (813) 287 -271 Fax: (813) 287 -5704 Es #0004221 : PE #17221 Seal Mark S. Egg ARCHITECT 211 East Bnw SkIest Gmnvwe, $C 2M01 T. BB4MM1111200 F. 11104 .7U7 Project At ITALIAN GRILL. .• i "N• �.•�\ South Miami, FV`! � : cQ r 5 ♦ q� �1 L� ^� Project Number 06165`, Drawn By Checked By Date 23 Mar 07 Y (,1 iQ LIFE SAFETY COMMENTS 5/23/07 AND OWNER CHANGES Drawing ELECTRICAL DETAILS, SCHEDULES, AND DIAGRAMS a