07-638-071ruiiCR rLrm uppar-niA . ivv 1 ` pi 1. ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION AND MOUNTING WITH MILLWORK CONTRACTOR PRIOR TO ROUGH —IN. 2. ALL KITCHEN APPLIANCES SHALL HAVE A DISCONNECTING MEANS TO COMPLY WITH 422 -20, 422 -21 (b) OR 422 -25 OF N.E.C. 3. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMP RECEPTACLES INSTALLED IN KITCHEN AREAS, SHALL BE ON CIRCUITS WITH G,F.C.I. PROTECTED CIRCUIT BREAKERS FOR PERSONNEL PER N.E.C. 210.9(8)(3). 4. ELECTRICAL CONTRACTOR SHALL REFER TO "FS' DRAWINGS FOR EQUIPMENTS ELECTRICAL REQUIREMENTS, MOUNTING HEIGHTS AND DIMENSIONS. 5. WHERE PORTIONS OF A CABLE, RACEWAY, OR SLEEVE ARE KNOWN TO BE SUBJECTED TO DIFFERENT TEMPERATURES AND WHERE CONDENSATION IS KNOWN TO BE A PROBLEM, THE RACEWAY OR SLEEVE SHALL BE FILLED WITH AN APPROVED MATERIAL TO PREVENT THE CIRCULATION OF WARM AIR TO A COLDER SECTION OF THE RACEWAY OR SLEEVE PER N.E.C. 300 -7 (a). 6 POWER PLAN SCALE: 1/4"=l'-O" H POWER PLAN NOTES O1 DISCONNECT SWITCH PROVIDED BY MECHANICAL, WIRED BY ELECTRICAL CONTRACTOR. O2 PROVIDE GFI CONVENIENCE OUTLET AT 16" A.F.F. Q3 PROVIDE POWER AND CONTROL WIRING IN EMT FROM WALK -IN REFRIGERATOR, WALK -IN FREEZER AND ICE CUBE MAKERS TO RESPECTIVE REMOTE CONDENSERS. SEE ICE MACHINE DETAIL ON SHEET FS -4. O4 INSULATED ALL CONDUIT PASSING THROUGH WALK -IN COOLER. FILL AROUND CONDUIT WITH DUCT -IN SEAL WHERE IT PASSES THROUGH COOLER WALL OR CEILING. O5 VERIFY LOCATION OF REMOTE CONDENSER UNITS PRIOR TO RUNNING CONDUIT. SEE ROOF PLAN. © ELECTRICAL CONTRACTOR SHALL PROVIDE WALL SIGN AND FLOOR MARKINGS NOTING WORKING CLEARANCES PER LOCAL CODE, ORDINANCES, OR REGULATIONS. 70 CEILING MOUNTED RECEPTACLE FOR TRELLIS LIGHTING FIXTURE "R" CONTROLLED VIA TOGGLE SWITCH. VERIFY LOCATIONS OF OUTLETS WITH ARCHITECTURAL SHEET "A2" TRELLIS PLAN. ® PROVIDE OUTLETS IN MECHANICAL ROOM. MOUNT AT 49" A.F.F. O PROVIDE DEDICATED DUPLEX OUTLET AT 94" A.F.F. FOR MUSIC SYSTEMS. 10 PROVIDE IVORY COLOR WIREMOLD 2000 IG SERIES PLUG MOLD #V201G606 WITH SINGLE RECEPTACLE AT 6. ON CENTER. MOUNT AT 18- A.F.F. (COUNTER TO HAVE GROMMETS) 11 CHEF'S COUNTER IS PRE -WIRED TO 150 AMP, 206V., 3 PH. LOAD CENTER (AT 10" A.F.F.). ELECTRICAL CONTRACTOR SHALL RUN PANEL FEED FROM 100 AMP, 3 POLE CIRCUIT BREAKER IN PANEL "MDP ". SEE PANEL SCHEDULES ON SHEET E -7. 12 PROVIDE DEDICATED DUPLEX OUTLET AT 84" A.F.F. FOR SECURITY SYSTEM. VERIFY WITH VENDOR PRIOR TO ROUGH -IN. 13 PROVIDE DOOR BELL (AND TRANSFORMER) AT 90" A.F.F. MOUNT EXTERIOR PUSHBUTTON AT 48" A.F.F. AT THE EXTERIOR GATT. OF TRASH ENCLOSURE. SEE DETAIL ON SHEET E -6. 14 PROVIDE 40 AMP, 4$OV., 3 PH., CIRCUIT BREAKER IN RECESSED NEMA 3R ENCLOSURE FOR DISHWASHER, WITH PHENOLIC NAME PLATE FOR IDENTIFICATION. MOUNT AT 6' -0" A.F.F. TO BREAKER HANDLE. VERIFY CONNECTION WITH EQUIPMENT SUPPUER, PRIOR TO PURCHASE. SEE WIRING DIAGRAM ON SHEET E -6. 15 PROVIDE 50 AMP, 490V., 3 PH., CIRCUIT BREAKER IN RECESSED NEMA 3R ENCLOSURE FOR ELECTRIC BOOSTER HEATER, WITH PHENOLIC NAME PLATE FOR IDENTIFICATION. MOUNT AT 6' -0" A.F.F. TO BREAKER HANDLE. VERIFY CONNECTION WITH EQUIPMENT SUPPUER, PRIOR TO PURCHASE. 1G FLUSH MOUNTED HORIZONTAL RECEPTACLE MOUNTED UNDER BAR COUNTER FOR TYPE "D" ROPE LIGHTING. 17 PROVIDE DUPLEX OUTLET AT 96" A.F.F. FOR CLOCK. 18 PROVIDE CONNECTION TO DETER ALARM BAR ON DOOR. VERIFY CONNECTION WITH EQUIPMENT SUPPUER. 1 9 MAINTAIN CLEARANCE FOR SODA AND REFRIGERATOR CHASSIS. COORDINATE IN FIELD, PRIOR TO INSTALLATION OF CONDUIT. 20 ELECTRICAL SHALL PROVIDE REMOTE STARTER AND MASTER SWITCHES FOR HOOD FAN RESET ON WALL MOUNTED AT 7' -0" A.F.F. ALSO INSTALL REMOTE RESETS FOR DUCT SMOKE DETECTORS ON ELECTRIC ROOM WALL (NOT SHOWN). SEE EXHAUST HOOD FAN CONTROL DIAGRAMS ON SHEET E -C. 21 MOUNT WAITRESS STATION OUTLETS AT 54" A.F.F. (TYP. U.O.N.) 2© PROVIDE ELECTRICAL CONNECTION FOR 120V., 1/20 HP RE- CIRCULATION PUMP CONTROLLED VIA TIME CLOCK. VERIFY REQUIREMENTS WITH PLUMBING CONTRACTOR. 23 PROVIDE TIME CLOCK TO CONTROL IRRIGATION SYSTEM. Q JUNCTION BOX FOR CONNEC11ON TO OVEN CONTROLS. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH GENERAL CONTRACTOR PRIOR TO ROUGH -IN. ©5 CONNECT TO GAS SOLENOID. VERIFY EXACT LOCATION PRIOR TO ROUGH -IN. �9 PANEL ENCLOSURE FOR LIGHTING CONTROLS. SURFACE MOUNT ABOVE ELECTRICAL PANEL HOFFMAN OR EQUAL SIZE AS REQUIRED. © PROVIDE DOORBELL (AND TRANSFORMER) AT 90' A.F.F. MOUNT EXTERIOR PUSHBUTTON AT 48" A.F.F. AT THE FRONT DOOR. SEE DETAIL ON SHEET E -6. PROVIDE SEPARATE TONE FOR DELIVERY BELL 2B ELECTRICIAN TO SUPPLY AND INSTALL CONTROLS BETWEEN CONDENSER HOOD FAN AND DISHWASHER CONTROL PANEL TO TURN FAN ON WHEN DISHWASHER IS ON AND TURN FAN OFF 5 MINUTES AFTER WASHER TURNS OFF. FAN SHALL ALSO RUN WHENEVER BOOSTER HEATER IS OPERATING. VERIFY ELECTRICAL REQUIREMENTS WITH THE HOOD FABRICATOR'S PLAN. REFER TO DETAIL SHEET E -C. 2� REFER TO MECHANICAL EQUIPMENT POWER WIRING DETAIL ON SHEET E -5 FOR CIRCUITRY AND DISCONNECTING MEANS. 30 WIRE KITCHEN EXHAUST AND SUPPLY FANS TO OPERATE SIMULTANEOUSLY IN NORMAL OPERATION. WHEN ANSUL SYSTEM TRIPS, HOWEVER, THE SUPPLY FAN MUST TURN OFF AND EXHAUST FANS MUST POWER ON. REFER TO EXHAUST HOOD FAN CONTROL DETAIL ON MECHANICAL PLANS. 31 206V., 1 PH., WEATHERPROOF SWITCH FOR ICE CUBE CONDENSER INTERCONNECT WITH ICEMACHINE PER MANUFACTURER'S REQUIREMENTS. 32 PROVIDE POWER AND CONTROL WIRING IN EMT FROM WALK IN REFRIGERATOR, WALK -IN FREEZER AND ICE CUBE MAKERS TO RESPECTIVE REMOTE CONDENSERS. 33 30 AMP FUSED SAFETY SWITCH, 209V., 3 PH., NEMA 3R, FUSED AT 25 AMPS. 34 30 AMP FUSED SAFETY SWITCH, 206V., 3 PH., NEMA 3R, FUSED AT 20 AMPS. 35 PROVIDE EXTERIOR RATED JUNCTION BOXES ON ROOF FOR CONNECTION TO SIGN ACCENT LIGHTS. VERIFY LOCATION PRIOR TO ROUGH -IN. SEE LIGHTING CONTROL DIAGRAM ON SHEET E -5. 36 PROVIDE 100 AMP, NON -FUSED SAFETY SWITCH, 48OV., 3 PH., NEMA 3R, SURFACE MOUNTED ON WALL FOR WATER HEATERS (TYPICAL). 31 (.-rk r c� '-v_1 C.� w I�% N 6 C z ova S Z1—z;r7 Harold Hart & Associates, Inc. CONSULTING ENGINEERS 4201 West Gray Street : Tam's, Fl *ri4do 336D9 Telephone: (813) 297 -2715 Fox; (913) 287 -5704 Ell #0004221 ; PE #17296 Seal ;r • Mark S. Eggl ARCHITECT 211 Eed Huai met Qrw livft !C 26901 T. 064232.9900 F. 0942327W Project c�►��xss,�s RALIAA GRILL. South Miami, FL Project Number 06165 Drawn By Checked By Date 23 Mar 07 1L LIFE SAFETY COMMENTS 5/23/07 AND OWNER CHANGES Drawing POWER PLAN E-2