Loading...
07-638-070_....... _. _ . _... - - -... .. ... -- — - - -- - — -- - -- - . _.._ ..... ._ ....... ....... _ ..._....... _ . ..... ...... _ _ _ __ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ [, LIGHTING PLAN V�V SCALE: 1 f 4 "= 1' -0" b LIGHTING PLAN NOTESi NOT USED 0 EMERGENCY/NIGHT LIGHTS SHALL BE CONNECTED TO AN UNSWITCHED LIGHTING CIRCUIT (TYPICAL). O3 NOT USED O4 NOT USED �5 NOT USED © NOT USED O7 DIMMER CABINET MASTER CONTROLLER "MSC12" IN 4 GANG RACO #698 SWITCH BOX (PROVIDED WITH CONTROLLER). RUN 4 #22 SHIELDED CABLE FROM CONTROLLER TO DIMMER PANEL CONTACT MARLIN CONTROLS AT (214) 553 -5700 FOR ADDITIONAL INSTALLATION INFORMATION. SEE DETAIL ON SHEET E -5. ® NOT USED O NOT USED 10 VAPOR RESISTANT FLUORESCENT LIGHTS PROVIDE BY COOLER MANUFACTURER. ELECTRICIAN TO WIRE LIGHTS INTO COOLER LIGHTING CIRCUIT. SEE SHEET E -2. 11 NOT USED 12 SWITCH KITCHEN LIGHTING CIRCUITS AT REAR EXIT. VERIFY LOCATION WITH ARCHITECT PRIOR TO INSTALLATION. 13 SWITCH FOR BATHROOM LIGHTING TO BE LOCATED IN KITCHEN. VERIFY MOUNTING LOCATION PRIOR TO INSTALLATION. 14 NOT USED 15 NOT USED 16 NOT USED 17 NOT USED 1sJ PROVIDE LEVITON INCANDESCENT SLIDE DIMMER WITH LED 1000VA CAT. IN110 -1LW (WHITE). WIRE CIRCUIT A -1 VIA DIMMER TO DUPLEX RECEPTACLE ITEM 301 FOR LIQUOR STORAGE CABINET LIGHTS. 1a PROVIDE LEVITON INCANDESCENT SLIDE DIMMER WITH LED 1000VA CAT. INI10 -1LW ( WHITE). LIGHTING PLAN GENERAL NOTES. 1. SEE ARCHITECTURAL CEILING PLAN FOR EXACT FIXTURE LOCATIONS. 2. SEE SHEET E -i FOR LIGHT FIXTURE SCHEDULE AND ELECTRICAL LEGEND. 3. ELECTRICAL CONTRACTOR SHALL REFER TO PAINT SPECIFICATIONS FOR LIGHT FIXTURES TO BE FIELD PAINTED. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE SHATTER PROOF LAMPS AT PASTA BAR. 5. ALL "EXIT" AND EMERGENCY LIGHT FIXTURES SHALL BE CONNECTED TO AN UNSWITCHED LEG LOCAL LIGHTING CONDUCTOR. t. 1,�, ; � E' 1 I• r s s' + �rj', - ate'" "',..�..•R•.�' .,. 1', k $ �., yfin, • •-c 6: ;w: ryt NOTE: FIXTURE PACKAGE IS AVAILABLE A= THROUGH REXEL CONSOLIDATED (LYLE DAMS OR KRISTI CLARK AT 1 -800 -486 -3256) OR SECURITY LIGHTING (STEVE FRIEDMAN OR BARD SHOOR AT 1- 800 - 544 - 4848). Harold Hart Ac Associates, Inc. CONSULTING ENGINEERS 4201 Weet Gray Street : Temps, Florid• 33600 Tele'hene: (813) 297 -2719 Fax: (913) 287 -5704 Es x!0004221 : RE #17286 Seel by , r ' � �•� Ste'- , fi,7 ta$ • r' Ll r, Mark S. Egg ARCHITECT 211 Earl ■row sweet QrrrrnEN sic 2"01 T. M4232 2W F. N4232.7U7 Project Goat-RABBgs RALIAI iRIIL. South Miami, FL Project Number 06165 Drawn By Checked By Date 23 Mar 07 Q1 LIFE SAFETY COMMENTS 5/23/07 AND OWNER CHANGES Drawing LIGHTING PLAN E000001 M1