Loading...
07-638-065PLUMBING FIXTURE SCHEDULE TOILET FIXTURES MARK DESIGNATION & SPECIFICATION COLD HOT TRAP/ VENT 17, A x o WATER WATER WASTE WC WATER CLOSET: AMERICAN STANDARD "MADERA" 2234.015 1" - 4" 2" FLOOR MOUNTED, 1.6 GPF, FLUSH VALVE, VITREOUS CHINA, ELONGATED, 14-1/8" HIGH BOWL, SIPHON JET, WATER SAVER. SEAT: OLSONITE J10 HEAVY DUTY, OPEN FRONT, LESS COVER U TRIM: FLUSH VALVE, SLOAN ROYAL 111, WITH BIO -GARD HANDLE. Seal WC -HC WATER CLOSET: AMERICAN STANDARD "MADERA" 2305.100 1" - 4" 2" FLOOR MOUNTED, 1.6 GPF, FLUSH VALVE, VITREOUS CHINA, ELONGATED 16-1/8- HIGH BOWL, SIPHON JET, WATER SAVER, rl �I i SEAT: OLSONITE #10 HEAVY DUTY, OPEN FRONT, LESS COVER 1 Mary S. Eggla TRIM: FLUSH VALVE, SLOAN ROYAL 111, WITH BIO -GARD HANDLE, (Y') 0 UR -HC URINAL: AMERICAN STANDARD "WASHBROOK" 6501.010 3/4" - 2° 2" WALL HUNG, 1.0 GPF, FLUSH VALVE, VITREOUS CHINA, W SIPHON JET WITH INTEGRAL TRAP, AND CP NUTS, TRIM: FLUSH VALVE, SLOAN ROYAL 186 -1, WITH 910 -GARD HANDLE. CARRIER: ZURN CARRIER Z -1222 WITH BOTTOM !TEARING PLATE. HANDICAP HEIGHT: 17 "AFF TO FRONT RIM. LAV -C LAVATORY: AMERICAN STANDARD "AQUALYN" 0476.028 1/2" 1/2" 1 -1/4" 2" COUNTER -TOP TYPE, SELF- RIMMING, 20 X 17" OVAL, WITH FRONT OVERFLOW, 0.5 GPM FLOW RESTRICTOR, AERATOR AND CP SUPPLIES WITH STOPS, CP ESCUTCHEONS, CP GRID DRAIN, CP TRAP WITH INTEGRAL CLEANOUT. TRIM: SINGLE LEVER FAUCET, AMERICAN STANDARD 2385.011, LESS POP -UP DRAIN AND HOLE. LAV -HC1 LAVATORY: AMERICAN STANDARD "AQUALYN" 0475.047 1/2" 1/2" 1 -1/4" 2" COUNTER -TOP TYPE, SELF - RIMMING, 20 X 17" OVAL, SINGLE HOLE, WITH FRONT OVERFLOW, 0.5 GPM FLOW RESTRICTOR, AERATOR AND CP SUPPLIES WITH STOPS, CP ESCUTCHEONS, CP GRID DRAIN, CP TRAP WITH INTEGRAL CLEANOUT. TRUEBRO 102 INSULATION KIT. FAUCET: SINGLE LEVER, SINGLE HOLE, AMER. STANDARD 2000.100, LESS POP -UP DRAIN AND HOLE. LESS ESCUTCHEON PLATE. LAV -HC2 LAVATORY HANDICAP: AMERICAN STANDARD "LUCERNE" 0355.012 1/2" 1/2" 1 -1/4" 2" WALL HUNG TYPE, 20 -1/2" X 18 -1/4" VITREOUS CHINA, FOR CONCEALED ARM SUPPORT, 0.5 GPM FLOW RESTRICTOR, AERATOR AND CP SUPPLIES WITH STOPS, CP ESCUTCHEONS, CP GRID DRAIN, CP TRAP WITH INTEGRAL CLEANOUT. HANDI -CAP OFFSET TAILPIECE. LAV GUARD: TRUEBRO 103E -7 INSULATION KIT. TRIM: SINGLE LEVER FAUCET, AMERICAN STANDARD 2385.011, LESS POP -UP DRAIN AND HOLE. CARRIER: ZURN Z--1231, MOUNT RIM AT HANDICAP HEIGHT. FD -T FLOOR DRAIN - TOILETS ZURN ZN -415 -P - - 3" 2" DURA- COATED CAST IRON BODY k ADJUSTABLE COLLAR. TRAP PRIMER CONNECTION. TYPE "B ", 6" DIAMETER, POLISHED NICKEL BRONZE STRAINER, WITH FLASHING CLAMP DEVICE. VINYL FLOORING (WHERE APPLICABLE) SHALL BE RUN BENEATH k CLAMPED DOWN BY THE FLASHING DEVICE. WATER HEATERS MARK DESIGNATION i SPECIFICATION COLD HOT TRAP/ VENT WATER WATER WASTE EWH ELECTRIC WATER HEATER: A.O. SMITH DSE- 120 -60 1 1/2" 1 1/2" - - 11� GALLON, FOAM INSULATED, TANK TYPE, 60 KW, 351 GPH RECOVERY CAPACITY AT 70 DEGREE F.RISE, ASME TANK 150 PSI RATED, 480 VOLTAGE, 3 PHASE, 90 AMPS. PROVIDE THE FOLLOWING ACCESSORIES FOR EACH EWK NOTE- (2)ELEMENT INDICATOR LIGHTS, (2) INDICATOR SWITCHES, (*DOOR INTERLOCK, WDIAL THERMOMETER, (1)GAUGE. TMV THERMOSTATIC MIXING VALVE BRADLEY VERNATHERM S55 -4009 - - - PISTON CONTROL MECHANISM AND WAX-- FILLED THERMOSTATIC CONTROL ELEMENT, BRONZE BODY, CHECK STOPS ON SUPPLY INLETS, DIRT AND LIME RESISTANT, 0.5 GPM MINIMUM FLOW, 3.5 GPM AT 10 FSI. RCP RECIRCULATING PUMP GRUNDFOS UP15 --42SU - - - - STAINLESS STEEL, 5 GPM AT 9 TH, 1/25 HP, UNION CONNECTION. PROVIDE JOHNSON CONTROL ADJUSTABLE THERMOSTATIC CONTROL MODEL A1SDAC -1C TO MAINTAIN 140 DEGREE HOT WATER RETURN. SANITATION FIXTURES MARK DESIGNATION & SPECIFICATION COLD HOT TRAP/ VENT WATER WATER WASTE JSB JANITORS SERVICE BASIN: FIELD FABRICATED BASIN 3/4" 3/4" 3" 2" TRIM: T k S FAUCET 6- 0665 -BSTR, HOSE 8- 0618 -01, HOSE BRACKET B -0654 AND MOP HANGER B -0653. DRAIN: ZURN Z- 415 -HD, TYPE "H ", 6" DIAMETER, WITH FLASHING CLAMP DEVICE. FD -P FLOOR DRAIN - PREP AREAS ZURN ZN- 415 -HD - - 3" 2" DURA - COATED CAST IRON BODY k ADJUSTABLE COLLAR. TYPE "H", 6" DIAMETER, POLISHED NICKEL BRONZE STRAINER, WITH FLASHING CLAMP DEVICE. - 4" - FS -12 FLOOR SINK ZURN LIGHT COMMERCIAL FD2377 -NH4 12 "x12 "x10" DEEP ENAMEL CAST IRON SINK WITH PVC ANTI - SPLASH INTERIOR BOTTOM DOME STRAINER, 1/2 GRATE. TRENCH PROVIDED BY OWNER AND INSTALLED BY PLUMBER - - 3" - DRAIN MISCELLANEOUS MARK DESIGNATION & SPECIFICATION COLD HOT TRAP/ VENT WATER WATER WASTE TP TRAP PRIMER: ZURN Z -1021 - - - - WATER SAVER TYPE, CP BRONZE, 1/2" PIPING AND ESCUTHEON PLATES. ROUTE PRIMER PIPING IN WALL TO FLOOR DRAIN. HB -1 HOSE ■IBB: WOODFORD #24 --3/4 - 3/4" - - WALL FAUCET, VACCUM BREAKER- BACKFLOW PROTECTED, MILD CLIMATE. WCO WALL CLEANOUT ZURN Z -1468 - - MATCH - STAINLESS STEEL, WITH 1/4 -20 SCREW TO CLEANOUT PLUG INSTALL PIPE 18" AFF. FCO FLOOR CLEANOUT ZURN ZN- 1400 -VP - - MATCH - INTERIOR, FLOOR TYPE. ABS TAPERED PLUG WITH GASKET SEAL k PIPE NICKEL BRONZE TOP. "C.O." CAST IN THE TOP. SPANNER WRENCH REMOVAL. AAV AIR ADMITTANCE VALVE STUDOR - - - - CODE APPROVED INDOOR VENT, INSTALLED IN ACCORDANCE WITH MANUFACTURER'S APPROVED INSTALLATION INSTRUCTIONS. MARK DESIGNATION & SPECIFICATION COLD HOT TRAP/ VENT WATER WATER WASTE DCV -A1 DOUBLE CHECK VALVE WATTS SERIES SD--3 ASSE 1022 - - OR WATTS SERIES 91) ASSE 1012 HEALTH HAZARD, CONTINUOUS OR INTERMITTENT PRESSURE. APPROVED DUAL CHECK WITH ATMOSPHERIC VENT. COFFFE MAKER TEA BREWER ESPRESSO MACHINE ICE MACHINE 1 4 " -3 DCV -A2 DOUBLE CHECK VALVE WATTS SERIES SD -3 ASSE 1022 - - - - HEALTH HAZARD, CONTINUOUS OR INTERMITTENT PRESSURE. APPROVED DUAL CHECK WITH ATMOSPHERIC VENT. CARBONATED BEVERAGE 1 2 " -1 1-14") AVI ATMOSPHERIC VACUUM BREAKER - - - - WATTS SERIES 298A: HEALTH HAZARD, CONTINUOUS PRESSURE. COMMERCIAL DISHWASHER JANITOR'S SINK 1 4" - 3" HCVB HOSE CONNECTION VACUUM BREAKER - - - WATTS SERIES 9: NOT SUBJECT TO CONTINUOUS PRESSURE. ASSE 1011 APPROVED. HOSE BIBB, WALL HYDRANT, WASHDOWN FUUCET, SERVICE SINK - I ­ . 1. APROVED MANUFACTURERS OF FIXTURES ARE AMERICAN STANDARD, KOHLER AND ELJER. 2. APROVED MANUFACTURERS OF FAUCETS ARE AMERICAN STANDARD, DELTA, T k S AND CHICAGO. 3. APROVFD MANUFACTURERS OF FLOOR DRAINS AND CLEANOUTS ARE J.R.SMITH, JOASM, WATTS AND ZURN. 4. APROVED MANUFACTURERS OF WATER COOLER IS ELKAY, OASIS AND HAWS. 5. APROVED MANUFACTURERS OF THE WATER HEATERS ARE A.O.SMITH, STATE, RHEEM AND RUUD. 6. ALL SUPPLIES SHALL BE PROVIDED WITH CHROME PLATED ANGLE STOPS AND TUBING EQUAL TO EASTMAN, BRASS -CRAFT OR EQUAL. PLUMBING GENERAL NOTES 1. WORK SHALL COMPLY WITH APPLICABLE NATIONAL, STATE,. AND LOCAL CODES INCLUDING: * 2004 FLORIDA BUILDING CODE WITH 2006 AMENDMENTS * 2004 FLORIDA PLUMBING CODE WITH 2006 AMENDMENTS * 2004 FLORIDA FUEL GAS CODE WITH 2006 AMENDMENTS * STATE ENERGY CODE 2. DEFINITIONS: "FURNISH" SHALL MEAN TO PURCHASE AND LOCATE AN ITEM ON THE JOBSITE. "INSTALL" SHALL MEAN TO PHYSICALLY INSTALL AN ITEM, AND TO CONNECT ALL REQUIRED SERVICES TO MAKE THAT ITEM FULLY FUNCTIONAL. "PROVIDE" SHALL MEAN TO BOTH FURNISH AND INSTALL AN ITEM. 3. VERIFY ALL POINTS OF CONNECTION WITH OTHER DISCIPLINES (LOCATION AND INVERT) PRIOR TO INSTALLATION. THIS SHALL INCLUDE EXISTING UTILITIES AS WELL AS NEW UTILITIES INSTALLED UNDER THE SCOPE OF WORK FOR THIS PROJECT, 4. COORDINATE WITH OTHER TRADES TO PREVENT INTERFERENCE WITH HVAC DUCTS, ELECTRICAL LIGHTING, AND STRUCTURE, IN THE CEILING PLENUMS. PRIORITY SHALL BE GIVEN TO HVAC DUCTWORK. 5. COORDINATE DROPPED FOOTERS AT ALL BUILDING FOUNDATION PENETRATIONS. PROVIDE SLEEVE THRU FOUNDATION WALL TWO NOMINAL PIPE SIZES LARGER THAN THE SERVICE PIPE. 6. ALL WORK, BOTH MATERIAL AND INSTALLATION, SHALL BE GUARANTEED FOR A MINIMUM OF ONE YEAR FROM THE DATE OF OWNER ACCEPTANCE (CERTIFICATE OF OCCUPANCY). SANITARY, WASTE AND VENT PIPING 1, SANITARY, WASTE AND VENT PIPING SHAL BE SCHEDULE 40 PVC PER ASTM D2665 (NO SUBSTITUTIONS) WITH SOLVENT WELDED CEMENT IN ACCORDANCE WITH ASTM 2564, 2. COORDINATE SANITARY AND WASTE PIPING BELOW THE SLAB WITH THE BUILDING FOUNDATIONS PRIOR TO INSTALLATION. 3. SET FLOOR DRAINS BELOW FINISHED FLOOR LEVEL TO ALLOW FULL DRAINAGE OF AREA. 4. EXPOSED DRAINS IN TOILETS SHALL BE CHROME- PLATED BRASS WITH ESCUTCHEONS. 5. PROVIDE CLEANOUTS AS REQUIRED BY CODE. 6 . FURNISH FOUR POUND LEAD O R E IGHT OUNCE COPPER FOR VENT THRU ROOF FLASHING TO THE GENERAL CONTRACTOR FOR INSTALLATION BY THE ROOFING SUBCONTRACTOR. 7. ALL INDIRECT PIPING SHALL TERMINATE AT THE RECEPTOR WITH A MINIMUM AIR GAP OF TWO PIPE DIAMETERS AND SHALL BE BEVELED AT 45 DEGREES. 8. ALL INDIRECT PIPING SERVING HAND SINKS, PREP SINKS, AND MISCELLANEOUS EQUIPMENT (I.E. ICE MACHINES, SODA STATIONS, ETC) SHALL BE COPPER. 9. ALL INDIRECT PIPING FROM PREP SINKS WITH MULTIPLE BASINS SHALL HAVE EACH BASIN DRAINED INDIVIDUALLY TO THE RECEPTOR. 10. TEST PIPING WITH A 10' WATER COLUMN FOR TWO HOURS. FIXTURE & EQUIPMENT LEGEND XX -XX� PLUMBING FIXTURE PROVIDED BY (X) PLUMBING CONTRACTOR ODE SIZING CRITERIA FOR THAT FIXTURE (PXXX) T.-PLUMBING NOTE REFERENCE FROM FOOD SERVICE SHEET FS -5 RESTAURANT PLUMBING OFFICAL QUESTIONNAIRE JOB /PROJECT • 06 -096 DATE 11/2/06 ADDRESS- SW 73RD ST, BETWEEN 58TH CT AND 55TH AVE BUILDING DEPARTMENT PHONE NUMIBER- 305 - 663 -6355 PLUMBING INSPECTOR- ROBERTO RAMIREZ PLAN REVIEWER ROBERTO RAMIREZ PHONE- 305 - 562 -5155 PHONE 305 - 562 -5185 PLUMBING CODE / YEAR FL 2004 GAS CODE / YEAR FL 2004 DRAINAGE SANITARY /GREASE /EITHER FLOOR DRAINS IN PREP AREAS: GREASE MOP SINKS IN PREP AREAS: GREASE BAR: SANITARY INDIRECT/DIRECT /EITHER UTENSILS SINK (TCS): GREASE INDIRECT FOOD PREP SINKS: GREASE INDIRECT HAND SINKS: EITHER EITHER DISHWASHER: GREASE DIRECT )ENSATE- STORM CONDENSATE DRAIN PROVIDED BY SHELL BUILDING) rTANCE WALVE- YES GREASE INTERCEPTOR- GALLONS 2500 QTY: (2) 1250'S EXPLANATION, THE SHELL DRAWINGS SIZED THE INTERCEPTORS FOR THIS TFAN) DUMPSTER PAD. REQUIREMENT& THE DRAINAGE FOR THE TRASH ENCLOSURE WAS INSTALLED BY THE SHELL BUILDING CONTRACTOR. FULL SPRINKLER PLANS, PHONE # 305-- 562 -5155 CONTACT PERSON: ROBERTO RAMIREZ ARE FULL PLANS (PIPE SIZES AND CALCULATIONS ) REQUIRED AT PERMIT-.,-(ES ARE SHOP DRAWINGS FROM THE CONTRACTOR ACCEPTABLE AFTER PERMIT? NO GAS COMPANY / SERVICE- THE SHELL BUILDING DOCUMENTS SHOW A 3" GAS SERVICE EXTENDING INTO THE SPACE, DELIVERING LOW PRESSURE. WATER SERVICE THE SHELL BUILDING DOCUMENTS SHOW A 2" WATER SERVICE EXTENDING INTO THE SPACE. A FLOW TEST CONDUCTED BY MIAMI -DADS COUNTY FIRE RESCUE DEPARTMENT, ON 4/13/06, AT 5829 SW 73RD ST, INDICATED 70 PSI STATIC __J TO EXISTING ENSATE DRAIN ) VVVU �,VV V vUWUU VvG V • V V V V V V • V i r V • V V • V V V V V u i V V V V v•• • V 4 V • V V 4 ••• •Gi r • • •r•V V V • u u uVu •u v • i V U V V W V V U v `rZE+Ct71'J uur u u • 0 1 Y V+ i V t o O .4 O W In z W c~7 u u uVu •u v • i V U V V W V V U D MUR 611U, W 0� z W W South Miami, FL co U) Project Number 06165 W Drawn By Checked By GG w Date 12 Apr 07 GRAVITY U) DRAINAGE PLAN UJ J U) 0 0 z P1 .1 v `rZE+Ct71'J uur u u uuu• v Ov�4 17, A x o O F U U Seal O U. rl �I i 1 Mary S. Eggla ARCHITECT (Y') 0 211 East Broad Sb* t Grwrnillo, SC 29601 1 1� T. 664.232.6200 F. 864.232,7567 0 Project W D MUR 611U, W 0� z W W South Miami, FL co U) Project Number 06165 W Drawn By Checked By GG w Date 12 Apr 07 GRAVITY U) DRAINAGE PLAN UJ J U) 0 0 z P1 .1