Loading...
05-675-006FOOTING; 5CHEIDULE: MARK SIZE REINFORCING REMARKS 2 #5 CONTINIOUS FTG. 1F" 941! ('.ONTININPI FTr a s SOIL STATEMENT THE SOIL AT THIS HAVQ MAN 6W.:13lED AND C(N�JST OF SAND, GRAVEL AND LIMESTGNE9 CLASSIFIES AS ROCKDALIf COMPLEX, WHICH IS CAPABLES OF SUPPORTING A MINIMUM LOAD OF 2000 POUNDS PER SQI2t.PE FOOT, ALTPE TIME, OF EXCAVATION, THIS OBSERVATION WIl 8c VERIFIED AD A SIGNED AND SEALED LETTER ATTESTINCi THAT THF, ONPITIONS AR SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED, SHALL SUBMITTED SOIL UNDER FOOTING AND SLABS SHALL BE COMPACTED TO A MIN. OF 95016 OF MAX. DRY DENSITY. COMPACTION SHALL BE CHECKED USING A MODIFIED PROCTOR TEST TO DETERMINE IN PLACE DENSITY. TEST SHALL BE MADE BY A CERTIFIED TESTING LABORATORY WITH REPORTS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER. STRUCTURAL NOTES 1, ALL POURED IN PLACE CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 P.S.I AT 28 DAYS. 2. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS ", ACI 301, UNLESS OTHERWISE NOTED. NO ADMIXTURES ARE PERMITTED WITHOUT WRITTEN APPROVAL. 4. REINFORCING STEEL IS TO BE NEW BILLET STEEL CONFORMING TO A.S.T.M. A -615, GRADE 60 SPECIFICATIONS, FABRICATED IN ACCORDANCE WITH THE "MANUAL OF STANDARD PRACTICE" OF THE C.R.S,I., UNLESS OTHERWISE NOTED,, AND PLACED IN ACCORDANCE WITH THE A.C.I. "BUILDING CODE AND MANUAL OF STANDARD PRACTICE ". 5. MINIMUM COVER: FOOTING 3 ": COLUMNS 2 ": BEAMS 1 -112: INTERIOR SLABS 1 ": EXPOSED SLABS 1 -1/2 ", UNLESS OTHERWISE NOTED. 6. ALL STRUCTURAL STEEL SHALL BE ASTM A -36 (Fy = 36000 P.S.I.) AND SHALL CONFORM TO A.I.S.C. SPECIFICATIONS. 7. ALL CONNECTIONS TO BE FIELD OR SHOP WELDED TO DEVELOP THE FULL STRENGH OF THE MEMBERS JOINED. 8, ALL BOLTS SHALL BE ASTM A -325. 9. SHOP COAT ALL STRUCTURAL STEEL WITH RUSTOLEUM "769" RED PRIMER. 10. ALL MASONRY WALLS SHALL BE CAPPED WITH AN 8" x 12" CONCRETE TIE BEAM WITH 2 - #5 BAR TOP AND BOTTOM: 4 - #3 TIES AT 12" IN EACH CORNER, #3 TIES AT 48" ELSEWHERE: PROVIDE #5 CORNER BARS EXTENDING 30" EACH WAY. TIE COLUMNS SHALL BE 8" x 12" WITH 4 - #5 VERTICAL AND No. 3 TIES @ 12" O.C. HORISONTAL JOINT REINFORCING SHALL BE PROVIDED AT EVERY SECOND COURSE (16" VERTICALLY) FOR EXTERIOR WALLS PROVIDE #9 LADDER TYPE FOR REINFORCED MASONRY AND TRUSS TYPE FOR ALL OTHERS SHALL BE PROVIDED. THIS REINFORCING SHALL EXTEND 4" INTO TIE COLUMNS OR TIE TO STRUCTURAL WITH APPROVED METHODS WHERE STRUCTURAL COLUMNS REPLACE THE TIE COLUMNS. COURSE LAP STEEL 36" 4 TIE W/ $13 TIE WIRE FIN. FLOOR EL. + 1' -011 Z FIN. GRADE z 4' CONC. 5LA5 ON GRADE W/ 6'X6 1.4x1.4 DOUBLE WWM OVER 6 MILL VAPOR BARRIER ON COMPACTED FILL 4 TERMITE TREATED SOIL ENO. CONC. FOOTING lU/ 2 -#5 WELL COMPACTED _2 L FILL OR UNDISTIRBED SOIL SCALE : 3/4" 0A 11. TIMBER SHALL BE No. 2 SOUTHERN PINE, PLYWOOD ROOF SHEATHING SHALL BE A MINIMUM THICKNESS OF 19/32" AND SHALL BE FASTENED TO SUPPORTS WITH 8d GALVANIZED COMMON NAILS WITH A MAXIMUM SPACING OF 6 INCHES ON CENTER IN THE FIELD AND AT GABLE EDGES WITH t Od NAILS AT 4" ON CENTER. 12, DOOR AND WINDOW OPENINGS IN MASONRY WALLS SHALL HAVE LINTELS CHECKED BY ARCHITECT /ENGINEER, LINTELS TO BE INTEGRAL WITH TIE BEAMS WHEN THE HEAD OF THE OPENING IS 16" OR LESS BELOW THE BOTTOM OF THE TIE BEAM. PROVIDED ADDITIONAL 2 - #5 BARS WHERE DROPS ARE 6" OR MORE. MINIMUM BEARING 8 INCHES EACH SIDE. MINIMUM LINTEL SHALL BE 8" DEEP WITH 2 44 TOP AND BOTTOM FOR SPANS LESS THAN 64": SPANS GREATER THAN 6' -0 ", 12" DEEP WITH 2 - 45 TOP AND BOTTOM, (USE HALF THE REINFORMENT FOR 4" WALLS. ALL MASONRY UNITS SHALL CONFORM TO ASTM C90, TYPE 1, GRADE NA WITH A MINIMUM SHELL FACE OF 1 -1/4 ". MINIMUM COMPRESSIVE STRENGTH (f'm) SHALL BE 2500 p.s.i. MORTAR SHALL CONFORM TO ASTM C270 TYPE M. REINFORECED MASONRY SHALL COMPLY WITH THE REQUIREMENTS OF "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES ", ACI 530 -92 / ASCE 5 92 / TMS402/92 AND THE FOLLOWING: A. VERTICAL SHELLS TO BE GROUTED SHALL PROVIDE VERTICAL ALIGNMENT TO MAINTAIN CLEAR, UNOBSTRUCTED CONTINUOUS VERTICAL CORES MEASURING NOT LESS THAN 2" x 3" AND SHALL BE KEPT CLEAR OF MORTAR PROTRU- SION AND DROPPINGS. B. GROUT SHALL BE A PLASTIC MIX WITH A SLUMP OF 9" ( +/ -1 MINIMUM COMPRESSIVE STRENGTH OF GROUT, (F,C), SHALL BE 3000 P.S.I. C. GROUT SHALL BE A PLACED BEFORE ANY INITIAL SET HAS TAKEN PLACE, AND THE GROUT SHALL NOT BE RETEMPERED WITH WATER. GROUTING SHALL BE ONE CONTINUOUS OPERA- TION IN LIFTS NOT TO EXCEED FOUR FEET, (4' -0 "), WITH A MAXIMUM POUR OF 12 FEET. D. GROUTING SHALL BE CONSOLIDATED BETWEEN LIFTS BY RODDING, PUDDING OR MECHANICAL VIBRATION. E. REINFORCING BAR SPLICES SHALL BE A MINIMUM OF 48 BAR DIAMETERS, 44 •• N DETAIL SCALE: 3/4" = 1' -0" 4' CONC. BLAB ON GRADE W/ 1.4x1.4 DOUBLE WWM OVER 6 MILL 1 ,,APOR BARRIER ON COMPACTED FILL 4 TERMITE TREATED 501E FIN. FLOOR 4' CONC. SLAB ON GRADE W/ 1,4x1.4 DOUBLE WWM OVER 6 MILL VAPOR BARRIER ON COMPACTED FILL 4 TERMITE TREATED SOIL COMPACT FILL TO S5% PROCTOR MAX. DENSITY WELL COMPACTED 601L FILL TERMITE TREATED COMPACT FILL TO SEM PROCTOR MAX. DENSITY WELL COMPACTED SOIL FILL TERMITE TREATED 16'X12' CONT. CONC. FOOTING W/ 2 -05's WELL COMPACTED FILL OR UNDISTURBED SOIL (TYP.) s� N *5X12' W/ 6' MIN EMBED 4 EPDXY e 16' O.C. EXIST. CMU CONC. WALL WOOD BASE EXIST. CONC. SLAB DETAIL � STARTER COL. SCALE : 3/4" = 1' -0" MICHAEL A. HERC)N, DESIGN quop BUILDING DESIGN, PLANNING, & INTERIORS 11010 SW 13TH STREET PEMBROKE PINES, FL 33025 PHONE: (954) 392.3801 FACSIMILE: (954) 392 -9929 EMAIL: mah design@aot.com Edward A. LANDERS�PE CONSULTING ENGINEERS P.E. NO 038398 7850 146TH ST, SUITE 509, MIAMI, FL 33016 PHONE: (305) 823.3938 FAX: (305) 823 -9355 W 0 W C) 0 W W Q � Q J < � W Q UJ Q Z N O 00 ^Q 0 Q LL 00 FILD IA.ME: 04.001.MP RROJECT 140.:04.001MP DATE: 11/07/04 DRAW,] BY: MP REVISIU(J B) DATE SHEET 1,1 C).