Loading...
05-675-0053' EXNAU° ROOF JAC mm SCALE: 1/4" = 1' -0" 1 46 GENERAL NOTES - PLUMBING 1. ALL WORIe4lANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE NATIONAL, STATE, SBC, RULES, ORDINANCES AND ANY OTHER PERTAINING CODES. 2. ALL MATERIAL SHALL BE NEW. 3. WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST -CLASS WORKMANLIKE MANNER. ALL MATERIALS SHALL BE NEW AND PROVIDED BY THIS CON- TRACTOR COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. 4. PROVIDE ALL EXCAVATIONS AND BACKFILL REQUIRED FOR THIS PHASE OF CONSTRUCTION. 5. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, TESTS AND INSURANCE REQUIRED FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 9). SUBMIT SHOP DRAWINGS TO THE ARCHITECT/ ENGINEER FOR REVIEW OF PLUMBING SYSTEM COMPONENTS. SUBSTITUTIONS REQUESTED BY THE CONTRACTOR SHALL BE PAID FOR BY THE CONTRACTOR 1. DRAWINGS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO SHOW EVERY MINOR DETAIL, NOR ARE THEY INTENDED TO BE SCALED FOR EXACT LOCATION OF FIXTURES, PIPING, OR ANY OTHER EQUIPMENT COMPONENTS. 6. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 9. BEFORE COMMENCING WORK, CONTRACTOR SHALL FIELD VERIFY LOCATIONS, SIZE, ELEVATION, AND ALL EXISTING UTILITIES AND POINTS OF CONNECTIONS. CONTACT ENGINEER IMMEDIATELY SHOULD ANY DISCREPENCIES BE ENCOUNTERED. 10. SOIL, WASTE, AND VENT PIPING SHALL BE NO -HUB CAST IRON SOIL PIPE. WHERE NOT IN AN A/C PLENUM OR UNDERGROUND AND AUTHORITIES ALLOW, PVC SCHEDULE 40 DWV MAY BE USED. II. CONTRACTOR SHALL GUARANTEE COMPLETE SYSTEM INCLUDING MATERIAL AND WORK- MANSHIP TO BE FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM FINAL DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL COST TO THE OWNER AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 12. ALL FIXTURES SHALL BE PROVIDED WITH READILY ACCESSIBLE STOPS /CLEANOUTS AND CONTROL VALVES. PROVIDE APPROVED AIR CHAMBERS AT EACH PLUMBING FIXTURE. 13. WHERE DISSIMILAR METALS ARE TO BE JOINED, APPROVED INSULATION UNIONS SHALL BE INSTALLED. 14. PROVIDE CLEANOUTS AT THE BASE OF EACH SOIL AND WASTE PIPE AND AT NO LESS THAN 75' LENGTHS OF PIPE. I5. ALL UNDERGROUND PIPING SHALL BE COPPER TYPE K. ALL OTHER WATER PIPING SHALL BE COPPER TYPE L. I (o. DOMESTIC WATER PIPING AIR CHAMBERS SHALL BE 20 PIPE DIAMETERS BUT NOT LESS THAN 12' LONG. AIR CHAMBERS SHALL BE PROVIDED AT EACH FIXTURE, GROUP OF FIXTURES, RISERS, AND ENDS OF SUPPLY LINES. 1 -1. SLOPE ALL 2" AND SMALLER a 1/4' AND LARGER Q I /8' OR MORE. PROVIDE ANTI -SCALD VALVES IN SHOWER. FLUMRING FIXTUfRE SCHEDULE FIXTURE MANUFACT. 4 MODEL No. CW HW WASTE TRAP REMARKS QI LAY. BY owNER 1/2' 1/2' 2' ui O TUB BY ouNER 1/2' 1/2' 2' co 0 IU.C. BY OJ4ER 1/2' 1/2' 3� INTEGRAL Cc w O U 3/4' TYPE M COPPER RELIEF VENT PIPE TO OUTSIDE ❑T WATER TO ADDITION OLD WATER TO HEATER EAT TRAPS RESSURE RELIEF 'ALVE 50 GAL HOT WATER HEATER AUX. DRAIN PAN EXIST. HOT WATER HEATER DETAIL_ NTS NOTES: ALL PLUMBING FIXTURES COMPLY WITH THE MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS. DESIGN BUILDING DESIGN, PLANNING, & INTERIORS I 11010 SW 13TH STREET PEMBROKE PINES, FL 33025 PI TONE: (954) 392 -3801 FACSIMILE: (954) 392 -9929 EMAIL: mah design@aoi.com EdwardA =: LANDERS, CONSULTING EON El P.e NO 038398 r. 7850146TH ST. SUITE 509, MIAMI, FL 33016 PHONE: (305) 823 -3938 FAX: (305) 823 -9355 FILENAVE: 04.001.W PROJE:T NO.:04.001.MP DATE: 11 107104 CRAWN BY: MP REVISION, BY DATE SHEET N0. M-P-1 ui U z ui 0 co m Cc w O U z � � � w co CO CO z � s J n. �0--� (.5 � Q _ cf) M j N .. L0 0 CL U- 71, FILENAVE: 04.001.W PROJE:T NO.:04.001.MP DATE: 11 107104 CRAWN BY: MP REVISION, BY DATE SHEET N0. M-P-1