05-930-006ELECTRICAL WORKING NOTES
I1 ONE DUPLEX OUTLET MOUNTED @ 18" A.F.F.
AND ONE DUPLEX OUTLET MOUNTED @ XX" A.F.F.
L3J
R4
E
a
❑8
F
10
11
12
11-31
14
15
16
TELEPHONE OUTLET MOUNTED @ 48" A.F.F.
T.V. OUTLET MOUNTED @ 8' -0" A.F.F.
OUTLET J.B. RECESS IN CONC. OR BLOCK WALL
ELEC. PANEL BOX RECESSED IN WALL
OUTLET @ 18" A.F.F. OF STAIR LANDING
OUTLET @ 18" A.F.F. UNDERNEATH STAIR
OUTLET @ 5' -0" A.F.F.
Y Y Y V
Y Y • fV • M • W • •
•ii• i • Y •
• W
Y Y • Y • • •
r••• • ri••• • oWY • !•ru •
ELECTRIC 24 HRS /7 DAY TIMER MOUNTED ON
WALL
FOR EACH OF THE FOLLOWING:
A.)
WATER HEATER
B.)
IRRIGATION PUMP
C.)
FUTURE POOL
D.)
• Y V •
Y
W
Y
! Y
•!• •ir •
Y
Y
MWYY
M W •
Y Y Y V
Y Y • fV • M • W • •
•ii• i • Y •
• W
Y Y • Y • • •
r••• • ri••• • oWY • !•ru •
ELECTRIC 24 HRS /7 DAY TIMER MOUNTED ON
WALL
FOR EACH OF THE FOLLOWING:
A.)
WATER HEATER
B.)
IRRIGATION PUMP
C.)
FUTURE POOL
D.)
PORCH LIGHTS -- TO BE INSTALLED W/ BYPASS SWITCH
ON WALL (SEE NOTE 36)
E.)
EXTERIOR WALL LIGHTS @ GARAGE ENTRANCE — TO BE
INSTALLED W/ BYPASS SWITCH
ON WALL (SEE NOTE 36)
F.)
FRONT AND EAST SECURITY LIGHTS — TO BE INSTALLED
W/ BYPASS SWITCH ON WALL
(SEE NOTE 36)
G.)
REAR AND WEST SECURITY LIGHTS — TO BE INSTALLED
W/ BYPASS SWITCH ON WALL
(SEE NOTE 36)
H.)
TERRACE LIGHTS -- TO BE INSTALLED W/ BYPASS SWITCH ON WALL (SEE NOTE 36)
I.)
LANDSCAPING SOUTH
J.)
LANDSCAPING EAST
K.)
LANDSCAPING NORTH
WATER HEATER J.B. @ 5' -0" A.F.F.
PROVIDE ELEC. OUTLET, LIGHT, do SWITCH INSIDE ROOF ATTIC SPACE
WALL TELEPHONE OUTLET MOUNTED ® 5' -0" A.F.F.
HVAC THERMOSTAT PROGAMABLE: 24 HRS./ 7 DAYS
ENTERTAINMENT SURROUND SOUND SYSTEM RECESSED
SPEAKERS MOUNTED IN CEILING
ALIGN THERMOSTAT BOX ABOVE ELECTRIC OUTLET BOX
OUTLET FOR MICROWAVE OVEN INSIDE KITCHEN CABINET
INSTALLED AT 64" A.F.F.
17 OUTLET FOR FREEZER /REFRIGERATOR.
18 OUTLET MOUNTED AT 4' -0"
19 OUTLET MOUNTED AT 12" A.F.F. BEHIND VANITY DRAWER
FOR HAIR DRYER
20 LOW VOLTAGE STRIP LIGHT UNDER TOP CABINETS
21 W TA TRIP IGHT ABOVE SOFFITS M U IN
LO VOL GE S L 0 LD G
22 EXTERIOR SECURITY, SEE A -6 do A -7 FOR DIMENSION LOCATION
23 MOUNT SECURITY LIGHT SWITCH @ 18" A.F.F., LINE UP BENEATH DIMMER SWITCHES
24 FOR ELECTRIC CIRCUIT WIRING E -3
25 FOR ELECTRIC CIRCUIT WIRING E-4
26 TO 3 WAY SWITCH IN ROOM 222. SEE DRAWING E4
27 TO 4 WAY DIMMER SWITCH IN ROOM 221. SEE DRAWING E4
1
28 TO 3 WAY SWITCH IN ROOM 103. SEE DRAWING E3 qg
29 TO SWITCH IN ROOM 108. SEE DRAWING E3
30 TO LOW VOLTAGE TRACK LIGHT IN CEILING. SEE DRAWING E4
31 TO DIMMER SWITCH IN ROOM 108. SEE DRAWING E3
32 INSTALL LIGHT FIXTURES do DIMMER SWITCH UNDER STAIR do STAIR LANDING
33 INSTALL J.B. BOX @ 18" A.F.F.
34 TO 3 WAY SWITCH IN ROOM 109, 102, do 105 EXT. SECURITY LIGHTS L
35 TO SECURITY LIGHT ON 2ND FLR. EXTERIOR WALL OF ROOM 233
36 BYPASS OVERRIDE LIGHT SWITCH. REFER TO NOTE 9D THRU 9G
37 ELECTRIC POWER FOR DISH WASHER
38 GARBAGE DISPOSAL ELECTRIC POWER do SWITCH
3g PROVIDE GROUNDING FOR GAS STOVE TO WATER LINE STUB —OUT
40 PROVIDE ELEC. OUTLET IN CIELING FOR GARAGE OPENER
41 SECURITY ALARM PANEL
42 3" SLEEVE WITH CONC. SLAB OF 2ND FLR. FOR SECURITY ALARM
43 6" X 12" SLEEVE OPENING THRU SLAB
44 (2) 2" SLEEVE THRU CONC. SLAB OF 2ND FLR. FOR ELEC. SEVICE TO PANEL "B"
45 UNDERCOUNTER FREEZER
46 UNDERCOUNTER REFRIGERATOR
47 ELECTRIC POWER FOR KITCHEN EXHAUST
1
F4 PROVIDE (1) 112" PVC CONDUIT TO FUTURE POOL EQUIP. LOCATION. SEE NOTE 11
49
PRnVIDE 1/2" CONDUIT do TELEPHONE WIRES TO J.B. FOR TELEPHONE ENTRY SYSTEM.
�i ` SIDE POWER WIRING TO EQUIPMENT AS REQUIRED.
.EFER TO APPLIANCE /EQUIPMENT SHOP DRAWINGS FOR POWER LOCATION. COORDINATE W/ G.C.
ROOM LEGEND
101 PORCH
102 FOYER
103 DINING ROOM
104 KITCHEN
105 KN❑ ❑K
106 FAMILY ROOM
107 TERRACE
108 LIVING ROOM
109 1ST FLR. HALL
110
BATHROOM NO. 1
.111 1ST. FLR, LINEN CLOSET
112 1ST, FLR. A/C CLOSET
11 � 1ST. FLR. HALL CLOSET
114 BEDROOM NO. 1
115 BEDROOM NO.1 CLOSET
116 BATHROOM NCI. 2
117 LAUNDRY
118
STORAGE ROOM
119 GARAGE
120 STAIRS
121 B.B.Q. AREA
221 2ND FLR, HALL
27.2 MASTER SUITE
223 MASTER BATH
224 PRIVATE BATH
225 HER MASTER CLOSET
226 HIS MASTER CLOSET
230 2ND FLR. A/C CLOSET
231 BEDROOM NO, 2
232
BEDROOM NO, 2 CLOSET
233 BEDROOM N❑. 3
234 3EDRO ❑M NO. 3 CLOSET
235
BATHROOM N❑. 3
ELECTRICAL SECOND FLOOR POWER PLAN
SCALE: 1/4" = T -0"
T.O.S. ELEV. 0' -0" - 14.55'
J�
113 � t 1
CONSTRUCTION
i • • a * • t • • ! . • •
ROBERT
TARA
FA
ROBERT TARAFA
6501 N.W. 36 ST., SUITE 101
MIAMI, FL 33166
Phone: 305.876.1440
Fax: 305.876.1441
.CIVIL
.STRUCTURAL
*LANDSCAPE
*DESIGN CONSULT-
.M /E /P
PROPOSED SINGLE
FAMILY RESIDENCE
5821 S.W. 56 TERRACE
LOT 59 BLOCK 1
SUBDIVISION GABLES EDGE
JOS NUMBER 2005.001
DATE: 15/26/05
REVISIONS /SUBMISSIONS
Q5-72-06 ADDED EMERGENCY ELECTRIC
GENERATOR AND RELATED ELECTRICAL
/\ CrK= CHANGES
n
DMVVM Trn-E
,y
J
ELECTRICAL
SECOND FLOOR
POWER PLAN
I MM NO E3