05-930(3)-042LEGEND NOTES COMPRESSOR UNITS
5 TON (EA.)
AIR HANDLING DESIGNATION
AHU NO. 1 & 2
1.
COMPRESING UNIT
10.
COIL GUARD
SUPPLY AIR (C.F.M.)
2.
COMPRESSOR ACCESS PANEL
11.
FAN GUARD
53,500
3.
BACK SEATED REFRIGERANT VALVE
12.
5" CONCRETE PAD W/ 6" X 6"
AIR HANDLER UNIT WIEGHT (LBS.)
4.
REFRIGERANT SUCTION UNIT
C. U. NO. 1 & 2
#10/ #10 W.W.F.
RHEEM
MODEL
WITH INSULATION. SEAL ENTRANCE
13.
REFRIGERANT SUCTION LINE
COMPRESSORS FLA
28.9
OF REFRIGERANT LINES INTO P.V.C.
1 (EA.)
SEER/ EER COP.
12.00
ELECTRIC DATA (V /PH)
RESILIENT
14.
6" DIA. SCHEDULE 40 PVC. SLEEVE
MIA ERI /LIMPERMEABLE
FOR REF. LINES (MAX. ANGLE 45
DEG.)
15.
1/8" STAINLESS STEEL CABLE
S.
SIGHT GLASS WITH MOISTURE
INDICATOR.
16.
COND. UNIT TO BE SECURED TO
CONC.
6.
REFRIGERANT LIQUID LINE W/O INSULATION
SLAB W/ (4) 1 -1/2" REMINGTON
POWER
FASTENERS X 3" TAPCONS PER
STRAP
7.
CONDUIT - POWER AND CONTROL
EA. END (TYP.). TO WITHSTAND
146 M.P.H.
8.
REFRIGERANT GAUGE CONNECTION
WINDS
9.
CONDENSER COIL
AIR - COOLED CONDENSING UNIT SLAB MOUNTED
FIBERGLASS
VELOCITY SUPPLY
)UCT
FLEXIBLE DUCT CONN.
JI�V VLL
DETAIL
NITS
26 MSG, 1 1/2" GALV. STRAPS
48" O.C. & EVERY ELL. W/ HILT]
RED HEADS, OR SCREWS ATTACHED
TO TRUSS OR SLAB PER SMACNA
STANDARDS (TYPICAL)
R -6 FLEX DUCT ON
1" THICK, 6" WIDE FIBERGLASS
SADDLES (TYPICAL)
DUCT SUPPORT DETAIL
NTS
NTS
2" PVC CONDENSAI
DRAIN W/ 3" TRAP
& CU PLUG TO OU1
GREEN AREA.
REFRIGERANT LINES 1
OUTSIDE CONDENSING
AHU MOUN-T[N.G
5 FIBERGLASS SUPLY DUCT
1/2" X 1 1/2" ANGLE
AROUND AHU S/A OUT
'OR DUCT SUPPORT
-LOUVERED DOOR
RUBBER ISOLATION PADS
EEL AHU SUPPORT
DETAIL,
NTS
EQUIPMENT SCHEDULE SPLIT SYSTEM
2 - SPLIT SYSTEM
5 TON (EA.)
AIR HANDLING DESIGNATION
AHU NO. 1 & 2
MANUFACTURER
RHEEM
MODEL
RBHC24J11 SFG
SUPPLY AIR (C.F.M.)
1800
HEATER (K.W.)
10.00
TOTAL COOLING (B.T.U. /H)
53,500
ELECTRIC SERVICE
1 -60- 208/230
TOTAL SENSIBLE HEAT GAIN
37,700
AIR HANDLER UNIT WIEGHT (LBS.)
CONDENSING UNIT DESIGNATION
C. U. NO. 1 & 2
MANUFACTURER
RHEEM
MODEL
RAMC060JAZ
NO. OF COMPRESSORS
1 (EA.)
COMPRESSORS FLA
28.9
NO. OF COMPRESSORS FANS
1 (EA.)
SEER/ EER COP.
12.00
ELECTRIC DATA (V /PH)
1 -60- 208/230
GENERAL NOTES
1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL ORDINANCES AND BUILDING
CODES GOVERNING THE INSTALLATION OF THE AIR CONDITIONING SYSTEM. IF WORK AS LAID
OUT INDICATED OR SPECIFIED IS CONTRARY TO, OR CONFLICT WITH LOCAL ORDINANCES,
BUILDING CODES AND REGULATIONS, THE CONTRACTOR SHALL REPORT IN WRITING TO THE
ARCHITECT /ENGINEER BEFORE SUBMITTING A BID. THE ARCHITECT /ENGINNER WILL THEN ISSUE
INSTRUCTIONS AS HOW TO PROCEED.
2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL
OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE
STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS.
CONTRACTOR SHALL FOLLOW THE DRAWINGS IN LAYING OUT WORK. CHECK DRAWINGS OF ALL
TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD
ROOM, AND SPACE CONDITIONS AT ALL POINTS, WHERE HEADROOM OR SPACE CONDITIONS
APPEAR INADEQUATE, ARCHITECT /ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH
INSTALLATION, THIS CONTRACTOR SHALL WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION
IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES FOR PROPER
EXECUTION OF THE WORK.
3. EXAMINE ALL DRAWINGS CAREFULLY AND VERIFY EXISTING CONDITION IN FIELD PRIOR TO SUBMITTING
A BID. CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND /OR CONNECT WITH APPROPRIATE
SERVICES ALL AIR CONDITIONING. IF DISCREPANCIES, CONFLICTS, INTERFERENCE OR OMISSIONS OCCUR
BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME TO PERMIT REVISIONS
BEFORE THE BIDS ARE SUBMITTED.
4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER, THE
OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH IN HIS
OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE APPEARANCE. REMOVAL AND
REPLACEMENT IS TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING AT
THE SOLE EXPENSE OF CONTRACTOR.
5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS
OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTORS
TO RECEIVE HIS WORK. THIS CONTRACTOR SHALL REMOVE AND REPLACE AT HIS
EXPENSE, ALL AIR - CONDITIONING WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF
INTERFERENCE WITH OTHER TRADES,
6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, ASSOCIATION DUES, PERMITS, TEST,
FINES, ROYALTIES, AND TAXES OF WHATEVER NATURE THAT SHALL APPLY TO THIS WORK. HE SHALL ALSO
PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE
OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF
THE LAWS, RULES OR ORDINANCES.
7. THE WORD "AIR CONDITIONING" MEANS HEATING, VENTILATION, AIR CONDITIONING, DUCT WORK,
PIPING, REFRIGERANT LINES, CONTROLS, SMOKE AND FIRE DAMPERS ETC.
8. PROVIDE MEANS "FURNISHING AND INSTALL ".
9. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE.
10. HVAC CONTRACTOR SHALL TEST AND BALANCE TO THE AIR QUANTITIES ON THE PLANS.
AND SHALL VISIT THE HOME AS MANY TIMES AS REQ'D BY OWNER TO FINE TUNE THE
HVAC SYSTEM.
11. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS.
12. THE HVAC CONTRACTOR SHALL WARRANT ALL WORKMANSHIP AND MATERIALS FOR ONE YEAR
FROM THE DATE OF FINAL WORK ACCEPTANCE BY OWNER, ANY BREAKDOWN OCCURRING IN FIRST
YEAR SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER. THE COMPRESSOR SHALL HAVE
FIVE YEARS WARRANTY.
13. MOUNT ALL EQUIPMENT FOR WIND LOADS AND MOUNTING HEIGHTS AS REQUIRED BY LOCAL
CODES.
14. AT COMPLETION OFJOB HVAC CONTRACTOR SHALL GIVE TO THE OWNER A SET OF AS- BUILTS
SHOWING THE EXACT INSTALLATION.
15. MOUNT ALL EQUIPMENT FOR WIND LOADS AND MOUNTING HEIGHTS REQUIRED BY LOCAL CODES.
HVAC DESIGN REQUIRES:
YES
NO
DUCT SMOKE DETECTOR
F
X
FIRE DAMPER(S)
H 11
X
SMOKE DAMPER(S)
X
FIRE RATED ENCLOSURE
X
FIRE RATED ROOF CEILING ASSEMBLY
X
FIRE STOPPING
X
SMOKE CONTROL
X
MECHANICAL NOTES AND DETAILS
SCALE: N.T.S.
T.O.S. ELEV. 0' -0" = 14.55'
TARAFA
CONSTRUCTION
ROB
E
T
TARA
F
A P E
C
H 11
T F
C T
ROBERT TAR.AFA
6501 N.W. 36 ST., SUITE 101
MIAMI, FL 33166
Phone: 305.876.1440
Fax: 305.876.1441
•CIVIL
•STRUCTURAL
•L
A
N
D S
C
A P E
•DESIGN
CONSULT:
.M /E /P
PROPOSED SINGLE
FAMILY RESIDENCE
5821 S.W. 56 TERRACE
LOT 59 BLOCK 1
SUBDIVISION GABLES EDGE
JOB NUMBER: 2005.001
DATE: 5/26/05
REVISIONS /SUBMISSIONS:
O
O
O
A
SEAL;
df
� „ r�;���` � •�� i, ,� iii
• o,
IC J' 0 u e
-PARa �,.:''RE@ X01 `
DRAWING TITLE:
MECHANICAL
NOTES AND
DETAILS
DRAWING NO: M3