Loading...
05-930(3)-039PLUMBING NOTES 1. ALL PLUMBING WORK AND MATERIALS SHALL BE PERFORMED IN ACCORDANCE LOCAL CODES, RULES, AND ORDINANCES, LATEST EDITION OF THE 'FLORIDA BUILDING CODE', CHAPTER 29, AND IN COMPLIANCE WITH THE 'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION. 2. FURNISH ALL LABOR, MATERIALS AND EQUIPEMENT REQUIRED FOR THE INSTALLATION OF THE SOIL, WASTE VENTS, DOMESTIC WATER HEATER, WATER LINES PLUMBING FIXTURES, AND ALL OTHER SYSTEMS REQUIRED AND INDICATED ON THE DRAWINGS FOR A COMPLETE AND OPERATING SYSTEMS. 3. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR, IN A FIRST CLASS WORKMANLIKE MANNER, WITH A FULLY OPERATIVE SYSTEM COMPLETE. 4. COORDINATE ALL WORK WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF THE CONSTRUCTION. 5. CONTRACTOR TO VERIFY AT SITE LOCATION THE ELEVATION AND SIZE OF EXISTING WATER AND SEWER MAINS FOR CONNECTION OF NEW SERVICES BEFORE INSTALLATION OF ANY PIPING. 6. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH COAT OF BITUMINOUS COMPOUND ('BITUSMATIC' OR EQUAL) BEFORE COVERING. ALL UNDERGROUND COPPER PIPING SHALL BE FULLY SLEEVED. 7. PROVIDE SHUT -OFF AND VACUUM BREAKER TO ALL HOSE BIBBS AND FAUCETS WITH HOSE -END CONNECTION. 8. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS OR SHOCK ABSORBERS. 9. PLUMBING FIXTURES SHALL BE 'AMERICAN STANDARD' OR APPROVED EQUAL. ALL FIXTURE TRIM SHALL BE CHROME PLATED. FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC. 10. WASTE LINES 2' OR LESS SHALL SLOPE 1/4' PER FOOT. WASTE LINES OVER 2' SHALL SLOPE 1/8' PER FOOT. PITCH TO BE UNIFORM 11. PROVIDE FULLY ACCESSIBLE CLEANOUTS ON SANITARY AND ANY WASTE PIPING AT EVERY CHANGE OF DIRECTION AND AT BOTTOM OF STACKS CLEAN OUT 0 CODON AND SIZES ON HORIZONTAL LINES SHALL BE 12. VENT LINES SHALL EXTEND 6' MIN. ABOVE ROOF AND FLASHED WITH LEAD OR CONNECTED TO EXISTING VENT LINES. 13. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMERS TO PROTECT THE SEAL OF THE TRAP. 14. PROVIDE CONTROL VALVES TO ALL MAINS ENTERING THE BUILDING, RISERS, BRANCHES, GROUPS OF FIXTURES, AND TO EACH PIECE OF EQUIPMENT. 15. FURNISH AND INSTALL CONDENSATE DRAIN PIPING TO DISCHARGE AT GRADE, 16. FURNISH AND INSTALL PRESSURE RELIEF VALVE AND LINE, AND TERMINATE AT THE EXTERIOR LOCATION TO PROVIDE READY, VISUAL INDICATION OF A FLOW. 17. PLUMBING VENTS WITHIN 10 FEET OF AN EXHAUST OUTLET, SHALL BE EXTENDED 3 FEET ABOVE SUCH OPENING. 18. THESE PLANS ARE SHOWN DIAGRAMATICALLY, ARE TO DEFINE THE INTENT AND SCOPE OF THE WORK ONLY. THE PLUMBING SUBCONTRACTOR IS RESPONSIBLE FOR ALL SIZING AND ADEQUACY OF THE SYSTEM. 19. WATER- HAMMER ARRESTORS SHALL BE INSTALLED WHERE QUICK - CLOSING VALVES ARE UTILIZED, UNLESS OTHERWISE APPROVED. WATER- HAMMER ARRESTORS SHALL CONFORM TO ASSE 1010, ACCESS SHALL BE PROVIDED TO WATER- HAMMER ARRESTORS 20. PLUMBING FIXTURES SHALL CONFORM TO THE FOLLOWING FOR MAX. WATER CONSUMPTION, WATER CLOSETS 1.6 GPM SINK FAUCETS 2.5 GPM LAVATORY FAUCETS 2.0 GPM SHOWER HEADS 2.5 GPM PIPING MATERIALS 1. SANITARY WASTE, VENT AND STORM DRAIN: POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS (SCHEDULE 40). MATERIAL SHALL COMPLY WITH D -1784, TYPE 1, GRADE 1 COMPOUND. PIPE SHALL COMPLY ;WITH ASTM D -1785. FITTINGS SHALL COMPLY WITH ASTM D -2467 SOCKET TYPE. SOLVENT CEMENT SHALL COMPLY WITH D -2564. 2. CONDENSATE DRAINS FROM AIR CONDITIONING UNITS: 'PVC' SCHEDULE 40 PIPE & FITTINGS. 3. DOMESTIC WATER ABOVE GROUND, TYPE L COPPER PIPE WITH WROUGHT COPPER SOLDERED JOINT FITTINGS. TYPE K COPPER BELOW GROUND PIPE ACCORDING TO ASTM B -42. TUBE ACCORDING TO ASTM B -88. ALTERNATE FOR UNDERGROUND PIPE, CAST IRON WATER PIPE ACCORDING TO ANSI A 21.6. STEEL PIPE (SCHEDULE 40, GALVANIZED) ACCORDING TO ASTM A120 -68. 4. ALL CONTROL VALVES FOR DOMESTIC WATER SHALL BE CAST BRASS OR B -88 BRONZE GATE VALVES. 5. INSTALL APPROVED DIELECTRIC UNIONS AT ALL LOCATIONS WHERE DISSIMILAR PIPING IS CONNECTED. ALL PIPING FROM WATER SERVICE (METER) TO BUILDING, SHALL BE OF THE SAME MATERIAL. 6. ALL HOSE BIBBS SHALL BE PROVIDED WITH VACUUM BREAKERS. PIPING MATERIALS 1. PIPE HANGERS AND SUPPORTS : PROVIDE ADJUSTABLE HANGERS, INSERTS BRACKETS, ROLLS, CLAMPS AND SUPPLEMENTARY STEEL AS REQUIRED FOR PROPER SUPPORT OF PIPE LINES. HANGERS SHALL ALLOW FOR EXPANSION AND CONTRACTION OF PIPE LINES AND COVERING TO RUN CONTINUOUSLY THROUGH HANGERS. 2. SPACING AND SIZES A. HORIZONTAL CARBON STEEL PIPE PIPE SIZE ROD DIAMETER MAXIMUM SPACING UP TO 1 -1/4' 3/8' 8' 1 -112' & 2' 3/8' 10' B. HORIZONTAL COPPER PIPING PIPE SIZE ROD DIAMETER MAXIMUM SPACING UP TO 1' 3/8' 6' 1 -1/4' & 1 -1/2' 3/8' 6' 2' 3/8' 8' 3. PROVIDE ANTI- SCALDING VALVE AT HOT WATER CONNECTIONS TO ALL AND SHOWERS, FIXTURE CONNECTION SCHEDULE FIXTURE SANITARY /WASTE WATER PIPE SIZE SLOPE HOT COLD TUB 2' 1/4' 1/2' 1/2' SHOWER 2' 1/4' 1/2' 1/2' CLOTHES WASHER 2' 1/4' 1/2' 1/2' BIDET 2' 1/4' 1/2' 1/2' BATHROOM SINKS 1 1/2' 1/4' 1/2' 1/2' TOILET 3' 1/8' 1/2' 1/2' REFRIDGERATOR - - 1/2' 1/2' �JAE DISH WAS ER '� 1/4' -• ' Ml/ H ❑SE BIBB - - 1/2' KITCHEN SINK 1 1/2' 1/4' 1/2' 1/2' BAR SINK 1 1/2' 1/4' 1/2' 1/2' WATER HEATER - - - 1' SHEET LEAD FLASHING MOP. IN WITH ROOFING MATERIAL NOTE: 0 54, ANY VENT PIPE WITHIN 10' -0" OF ANY DOOR, WINDOW,OR EXHAUST OPENING SHALL EXTEND NOT LESS THAN 3' -0" ABOVE SUCH. N INTO STACK IG STRUCTION SLEEVE ROOF CONSTRUCTION AS REQUIRED VENT THRU R❑ ❑E DETAIL N.T.S. • s. - ���... -:F� j•.- ;:c.'� +il+� ..,.yJ� •'+ -u °: +is�' ;e, "v"`.C.N�� �ti j,, .�_ - P "s- ... s-`�- '��•:+S'L^.;'\, �.`2�'er �i ..,b,'•S�•. ,- .R4•'yi•;1i� ra^•�:' ^,%.3 i�•, v,: , �' Fi . L r +1. , . FINAL rl ^^m -- --- • --- TABLE R TYPICAL FLOOR DRAIN DETAIL N,T,S, �- STAINLESS STEEL COVER SCREWED TO THREADED C.O. PLUG FACE OF WALL TYPICAL CLEAN ❑UT DETAIL N,T,S, PLUMBING DETAILS SCALE: N.T.S. T.O.S. ELEV. 0' -0" = 14.55' TARAFA CONSTRUCTION ROB ERT TARAFA ARCH ITiECT ROBERT TARAFA 6501 N.W. 36 ST. SUITE 101 MIAMI, FL 331661 Phone: 305.876.1440 Fax: 305.876.1441 .CIVIL •S T R U C T U R A L •L A N D S C A P E .D E S I G N C 0 N!S U L T: .M /E /P I PROPOSED SINGLE FAMILY RESIDENCE 5821 S.W. 56 TERRACE LOT 59 BLOCK 1 SUBDIVISION GABLES EDGE JOB NUMBER: DATE: 2005.001 5/26/05 REVISIONS /SUBMISSIONS: 0. A L "A "A n SEAL: 'i ; •;j iI A '••0!6, 0,, AR �tG,Qf�.O�`701 DRAWING TITLE:'-,­' PLUMBING DETAILS AND NOTES .DRAWING .NO: - P7 • .ir � � -�iC ,