05-930(3)-039PLUMBING NOTES
1. ALL PLUMBING WORK AND MATERIALS SHALL BE PERFORMED IN ACCORDANCE
LOCAL CODES, RULES, AND ORDINANCES, LATEST EDITION OF THE 'FLORIDA
BUILDING CODE', CHAPTER 29, AND IN COMPLIANCE WITH THE
'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION.
2. FURNISH ALL LABOR, MATERIALS AND EQUIPEMENT REQUIRED FOR THE
INSTALLATION OF THE SOIL, WASTE VENTS, DOMESTIC WATER HEATER,
WATER LINES PLUMBING FIXTURES, AND ALL OTHER SYSTEMS REQUIRED AND
INDICATED ON THE DRAWINGS FOR A COMPLETE AND OPERATING SYSTEMS.
3. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR,
IN A FIRST CLASS WORKMANLIKE MANNER, WITH A FULLY OPERATIVE
SYSTEM COMPLETE.
4. COORDINATE ALL WORK WITH OTHER TRADES TO AVOID INTERFERENCE
WITH THE PROGRESS OF THE CONSTRUCTION.
5. CONTRACTOR TO VERIFY AT SITE LOCATION THE ELEVATION AND SIZE
OF EXISTING WATER AND SEWER MAINS FOR CONNECTION OF NEW
SERVICES BEFORE INSTALLATION OF ANY PIPING.
6. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH COAT OF
BITUMINOUS COMPOUND ('BITUSMATIC' OR EQUAL) BEFORE COVERING.
ALL UNDERGROUND COPPER PIPING SHALL BE FULLY SLEEVED.
7. PROVIDE SHUT -OFF AND VACUUM BREAKER TO ALL HOSE BIBBS AND
FAUCETS WITH HOSE -END CONNECTION.
8. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR
CHAMBERS OR SHOCK ABSORBERS.
9. PLUMBING FIXTURES SHALL BE 'AMERICAN STANDARD' OR APPROVED
EQUAL. ALL FIXTURE TRIM SHALL BE CHROME PLATED. FIXTURES
SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC.
10. WASTE LINES 2' OR LESS SHALL SLOPE 1/4' PER FOOT. WASTE LINES
OVER 2' SHALL SLOPE 1/8' PER FOOT. PITCH TO BE UNIFORM
11. PROVIDE FULLY ACCESSIBLE CLEANOUTS ON SANITARY AND ANY WASTE
PIPING AT EVERY CHANGE OF DIRECTION AND AT BOTTOM OF STACKS
CLEAN OUT 0 CODON AND SIZES ON HORIZONTAL LINES SHALL BE
12. VENT LINES SHALL EXTEND 6' MIN. ABOVE ROOF AND FLASHED WITH
LEAD OR CONNECTED TO EXISTING VENT LINES.
13. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMERS TO PROTECT THE SEAL
OF THE TRAP.
14. PROVIDE CONTROL VALVES TO ALL MAINS ENTERING THE BUILDING,
RISERS, BRANCHES, GROUPS OF FIXTURES, AND TO EACH PIECE OF
EQUIPMENT.
15. FURNISH AND INSTALL CONDENSATE DRAIN PIPING TO DISCHARGE
AT GRADE,
16. FURNISH AND INSTALL PRESSURE RELIEF VALVE AND LINE, AND
TERMINATE AT THE EXTERIOR LOCATION TO PROVIDE READY,
VISUAL INDICATION OF A FLOW.
17. PLUMBING VENTS WITHIN 10 FEET OF AN EXHAUST OUTLET, SHALL
BE EXTENDED 3 FEET ABOVE SUCH OPENING.
18. THESE PLANS ARE SHOWN DIAGRAMATICALLY, ARE TO DEFINE THE
INTENT AND SCOPE OF THE WORK ONLY. THE PLUMBING SUBCONTRACTOR
IS RESPONSIBLE FOR ALL SIZING AND ADEQUACY OF THE SYSTEM.
19. WATER- HAMMER ARRESTORS SHALL BE INSTALLED WHERE QUICK - CLOSING
VALVES ARE UTILIZED, UNLESS OTHERWISE APPROVED. WATER- HAMMER
ARRESTORS SHALL CONFORM TO ASSE 1010, ACCESS SHALL BE PROVIDED
TO WATER- HAMMER ARRESTORS
20. PLUMBING FIXTURES SHALL CONFORM TO THE FOLLOWING FOR MAX. WATER
CONSUMPTION,
WATER CLOSETS 1.6 GPM
SINK FAUCETS 2.5 GPM
LAVATORY FAUCETS 2.0 GPM
SHOWER HEADS 2.5 GPM
PIPING MATERIALS
1. SANITARY WASTE, VENT AND STORM DRAIN:
POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS (SCHEDULE 40). MATERIAL
SHALL COMPLY WITH D -1784, TYPE 1, GRADE 1 COMPOUND. PIPE SHALL
COMPLY ;WITH ASTM D -1785. FITTINGS SHALL COMPLY WITH ASTM D -2467
SOCKET TYPE. SOLVENT CEMENT SHALL COMPLY WITH D -2564.
2. CONDENSATE DRAINS FROM AIR CONDITIONING UNITS: 'PVC' SCHEDULE 40
PIPE & FITTINGS.
3. DOMESTIC WATER ABOVE GROUND, TYPE L COPPER PIPE WITH WROUGHT
COPPER SOLDERED JOINT FITTINGS. TYPE K COPPER BELOW GROUND PIPE
ACCORDING TO ASTM B -42. TUBE ACCORDING TO ASTM B -88.
ALTERNATE FOR UNDERGROUND PIPE, CAST IRON WATER PIPE ACCORDING
TO ANSI A 21.6. STEEL PIPE (SCHEDULE 40, GALVANIZED) ACCORDING TO
ASTM A120 -68.
4. ALL CONTROL VALVES FOR DOMESTIC WATER SHALL BE CAST BRASS OR
B -88 BRONZE GATE VALVES.
5. INSTALL APPROVED DIELECTRIC UNIONS AT ALL LOCATIONS WHERE
DISSIMILAR PIPING IS CONNECTED. ALL PIPING FROM WATER SERVICE
(METER) TO BUILDING, SHALL BE OF THE SAME MATERIAL.
6. ALL HOSE BIBBS SHALL BE PROVIDED WITH VACUUM BREAKERS.
PIPING MATERIALS
1. PIPE HANGERS AND SUPPORTS : PROVIDE ADJUSTABLE HANGERS, INSERTS
BRACKETS, ROLLS, CLAMPS AND SUPPLEMENTARY STEEL AS REQUIRED FOR
PROPER SUPPORT OF PIPE LINES. HANGERS SHALL ALLOW FOR EXPANSION
AND CONTRACTION OF PIPE LINES AND COVERING TO RUN CONTINUOUSLY
THROUGH HANGERS.
2. SPACING AND SIZES
A. HORIZONTAL CARBON STEEL PIPE
PIPE SIZE ROD DIAMETER MAXIMUM SPACING
UP TO 1 -1/4' 3/8' 8'
1 -112' & 2' 3/8' 10'
B. HORIZONTAL COPPER PIPING
PIPE SIZE ROD DIAMETER MAXIMUM SPACING
UP TO 1' 3/8' 6'
1 -1/4' & 1 -1/2' 3/8' 6'
2' 3/8' 8'
3. PROVIDE ANTI- SCALDING VALVE AT HOT WATER CONNECTIONS TO ALL
AND SHOWERS,
FIXTURE CONNECTION SCHEDULE
FIXTURE
SANITARY /WASTE
WATER
PIPE SIZE
SLOPE
HOT
COLD
TUB
2'
1/4'
1/2'
1/2'
SHOWER
2'
1/4'
1/2'
1/2'
CLOTHES WASHER
2'
1/4'
1/2'
1/2'
BIDET
2'
1/4'
1/2'
1/2'
BATHROOM SINKS
1 1/2'
1/4'
1/2'
1/2'
TOILET
3'
1/8'
1/2'
1/2'
REFRIDGERATOR
-
-
1/2'
1/2'
�JAE
DISH WAS ER
'�
1/4'
-•
'
Ml/
H ❑SE BIBB
-
-
1/2'
KITCHEN SINK
1 1/2'
1/4'
1/2'
1/2'
BAR SINK
1 1/2'
1/4'
1/2'
1/2'
WATER HEATER
-
-
-
1'
SHEET LEAD FLASHING
MOP. IN WITH ROOFING
MATERIAL
NOTE:
0
54,
ANY VENT PIPE WITHIN 10' -0"
OF ANY DOOR, WINDOW,OR EXHAUST
OPENING SHALL EXTEND NOT LESS
THAN 3' -0" ABOVE SUCH.
N INTO STACK
IG
STRUCTION
SLEEVE ROOF CONSTRUCTION
AS REQUIRED
VENT THRU R❑ ❑E DETAIL
N.T.S.
• s. - ���... -:F� j•.- ;:c.'� +il+� ..,.yJ� •'+ -u °: +is�' ;e, "v"`.C.N�� �ti j,, .�_ - P
"s- ... s-`�- '��•:+S'L^.;'\, �.`2�'er �i ..,b,'•S�•. ,- .R4•'yi•;1i� ra^•�:' ^,%.3 i�•, v,: , �' Fi .
L r
+1. , .
FINAL
rl ^^m -- --- • ---
TABLE
R
TYPICAL FLOOR DRAIN DETAIL
N,T,S,
�- STAINLESS STEEL COVER
SCREWED TO THREADED
C.O. PLUG
FACE OF WALL
TYPICAL CLEAN ❑UT DETAIL
N,T,S,
PLUMBING DETAILS
SCALE: N.T.S.
T.O.S. ELEV. 0' -0" = 14.55'
TARAFA
CONSTRUCTION
ROB ERT TARAFA
ARCH ITiECT
ROBERT TARAFA
6501 N.W. 36 ST. SUITE 101
MIAMI, FL 331661
Phone: 305.876.1440
Fax: 305.876.1441
.CIVIL
•S T R U C T U R A L
•L A N D S C A P E
.D E S I G N C 0 N!S U L T:
.M /E /P
I
PROPOSED SINGLE
FAMILY RESIDENCE
5821 S.W. 56 TERRACE
LOT 59 BLOCK 1
SUBDIVISION GABLES EDGE
JOB NUMBER:
DATE:
2005.001
5/26/05
REVISIONS /SUBMISSIONS: 0.
A
L
"A
"A
n
SEAL:
'i ; •;j iI A '••0!6, 0,,
AR �tG,Qf�.O�`701
DRAWING TITLE:'-,'
PLUMBING
DETAILS AND
NOTES
.DRAWING .NO: - P7
• .ir � � -�iC ,