09-709-034
l t (a) (a) (a) 204240V PANEL "A" 150 M.L.O. 1 PH.3W SURFACE MID BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKERI TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A COVERED TERR. #12- -1 /2 "C BEDROOM 1 1P -20 1 2 1P -20 1500 #12 -1 /2 "C DINING REC. COVERED TERR. 2 #4 -1 -C AHU No.3 1500 1 1 3 3 4 TELEPHONE OUTLET 1500 1500 4 60 APPLIANCES FOYER (10 KW) 1500 2 WALL SWITCH 15A, 1.25V 5 6 5 6 1500 5 1500 2P (2000) APPLIANCES FOYER 2P 2 8 /L Y 900 7 8 7 8 1500 (2000) 40 APPLIANCES CORRIDOR 3 • 600 V • Y GARAGE 9 10 10 2P 1000 2 #4 --1 "C AHU No.4 DISHWASHER CORRIDOR y V• u Y G. OPENER i u V 4 V V V 11 12 60 5500 800 (10 KW) MASTER . BED G. DISPOSAL ENTRY 600 V 13 14 13 14 11 CU No.4 1500 BED MICROWAVE DINING LTG 600 15 16 40 15 1 16 F2P 4000 2 #6, 1#10 DOUBLE FAMILY ROOM 17 18 17 18 17 18 50 4000 1 #10 GRD-3/4-C OVEN FAMILY ROOM 19 20 19 19 20 2P 3000 2 #8, 1 #10 COOK TOP FAMILY ROOM 21 21 22 40 3000 1 #10 GRD -3/4 "C STAIRS LIVING ROOM 800 23 23 23 24 2P 5500 '2 #4 -1 "C AHU 1 LIVING ROOM 2P 1200 26 2P 25 26 25 26 60 5500 U.C. REFR. (10 KW) LIVING ROOM 1200 5900 27 28 1 P -20 27 28 2P (2100) 2 #8 -3/4 "C C.U. 1 GUEST ROOM 11 MOTOR 29 30 1P-20 1600 29 30 50 (2100) #12 -1/2 "C BBQ. REFR. GUEST ROOM 31 32 1P -20 33 1 1 31 132 2P 5500 2 #4 -1 "C AMU 2 TERRACE 1P -20 1 36 11 1 33 34 60 5500 (10 KW) BATH RECEPT. 138 1000 37 38 35 36 2P (2100) 2 #8 -3/4 "C C.U. 2 SPACE 1000 39 40 37 38 50 (2100) 41 42 41 42 SPACE * 940 S.F. 39 140 1 1 8757 SPACE SUBTOTAL 118,1201 SUBTOTAL 10,557 41 42 SUBTOTAL SPACE �k 3000 S.F. 9000 SUBTOTAL 91000 TOTAL = 54,300 45,300 SUBTOTAL (a) AFCI C/B DEMAND LOAD = 32.3 KW A/C O 100%= 4200 FIRST 10 KW • 100 % = 10.0 KW HEAT • 65% =7150 22.3 KW O 40 % 8.92 KW A/C (7.15 + 7.15) = 14.30 KW 33.22 KW (138A) 120 PANEL "E 1PH.3.1Q( (2nd. FLOOR) " 200_M.L.o. FLUSH MTD BRANCH CIRCUITS WIRE AND CONDUIT LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A BEDROOM 1 #12 -1/2 "C 1 2 113-20 1 2 2P 5500 2 #4 -1 -C AHU No.3 1500 1 FUSE OR DISCONNECT SWITCH 3 4 V TELEPHONE OUTLET 1500 3 4 60 550 PUSHBUTTON (10 KW) 1500 2 WALL SWITCH 15A, 1.25V 5 6 157.377 FOUR WAY TOGGLE SWITCH 1500 5 6 2P (2000) 2 #8 -3/4 "C CU No.3 2P 2 8 /L Y 900 GROUND -FAULT INTERRUPTER WP 7 8 40 (2000) 40 9 1 10 3 • 600 V • Y GARAGE KITCHEN LTG. 9 10 2P 5500 2 #4 --1 "C AHU No.4 V V 3 y V• u Y G. OPENER i u V 4 V V V 11 12 60 5500 r (10 KW) MASTER . BED yyuU 600 V 13 14 2P (2000) 2 #8-3/4 "C CU No.4 BED 15 16 600 15 16 40 (2000) STAIRS W L r V BATH 17 18 17 18 2P 1000 2 #8 -3/4 "C IWH -3 BED 19 20 19 20 40 1000 (8.5KW) GALLERY 21 22 2P 5900 2 #6 -3/4 "C IWH -4 STAIRS 800 23 23 24 60 5900 (4.2 KW) (11.8KW) FLOOD LIGHTS 800 2P 1200 26 2P 25 26 1 P -20 * #12-1/2-C BATH RECEPT. U.C. REFR. 27 28 1200 5900 27 28 1 P -20 800 2P 29 BATH RECEPT. SPARE 900 #12 -1/2 "C 11 MOTOR 29 30 1P-20 1600 11 WHIRPOOL SPACE #12 -1/2 "C BBQ. REFR. LANDSCAPE 31 32 1P -20 33 ; Soo SPARE 33 34 900 1P -20 1 36 11 Soo 35 36� 37 138 1000 37 38 39 40 1000 39 40 41 42 41 42 SPACE * 940 S.F. + �k 2819 S.F. 1 8757 SUBTOTAL 118,1201 SUBTOTAL 10,557 TOTAL 52,857 42,300 SUBTOTAL (a). AFCI C/B (b) ON TIMER (C) GFI A/C O 1007:= 4200 HEAT • 659e =7150 DEMAND LOAD = 30.9 KW FIRST 10 KW O 100% = 10.0 KW 20.9 KW • 40 9e = 8.36 KW A/C (7.15 + 7.15) = 14.30 KW 32.66 KW (136A) (a) (a) 120/240V PANEL "C" 200A M.L.O. 1 PH. 3W ,SURFACE M.T.D. BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKE TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A REFRIGERATOR #12 - 1/2 "C 1500 1P -20 1 2 1P -20 1500 #12 -1/2 "C BAR WINE COOLER WASHER 4,6 SPACE 1500 G V V FUSE OR DISCONNECT SWITCH 3 4 V TELEPHONE OUTLET 1500 TELEVISION OUTLET �o BAR RECEPTACLES WASHER PUSHBUTTON U V v 1500 • WALL SWITCH 15A, 1.25V 5 6 157.377 FOUR WAY TOGGLE SWITCH 1500 SAFETY DISCONNECT SWITCH e BAR LTG. DRYER 3 #10 -1/2 "C 2500 2P 7 8 /L Y 900 GROUND -FAULT INTERRUPTER WP GARAGE SD SMOKE DETECTOR 2500 40 9 1 10 Y V • 600 V • Y GARAGE KITCHEN LTG. #12 - 1/2 "C * 1P -20 11 1 12 " V V 600 y V• u Y G. OPENER i u V 4 V V V V i Y r 13 14 yyuU 600 V • 15 16 600 V V V V GV r r U• Y STAIRS W L r V W u V V V 17 18 900 FLOODS DEN 19 20 1500 LAUNDRY DEN 21 22 2P 2100 2 #10 -1/2 -C IWH -1 ENTRANCE COLUMN LTG. 800 23 24 20 2100 (4.2 KW) GATE No.1 2 #12 - 1/2 "C 800 2P 25 26 2P 5900 2 #6 -3/4 "C IWH -2 MOTOR 800 20 27 28 60 5900 (11.8 KW) GATE No.2 2 #12 - 1/2 "C 800 2P 29 30 1P -20 900 #12 -1/2 "C COURYARD MOTOR 800 20 31 32 1200 #12 -1/2 "C BBQ. REFR. LANDSCAPE #12 - 1/2 "C 900 1P -20 33 34 Soo SPARE LANDSCAPE #12 - 1/2 "C 900 1P -20 35 36 11 Soo SPARE SPACE 37 138 1000 FUTURE 39 40 1000 POOL PUMP 41 42 SPACE * 940 S.F. 2820 SUBTOTAL 118,1201 TOTAL = 50,220 132,1001 SUBTOTAL (a) AFCI C/B DEMMD LOAD = 50.22 KW FIRST 10 KW O 100% = 10.0 KW 40.22 KW 0 40 7 = 16.09 KW 26.09 KW (109A) 120/240V PANEL IIMII 400A MLO 1 PH, 3W W.PROOF) SURFACE MTD CKT. NO. DESCRIPTION C/B TRIP LOAD WIRE CONDUIT REMARKS 1 PNL "A" 2P --200 54,300 3 #3/0, 1 #6 GIRD -- 2"C MAIN #1 2 PNL "B" 2P -200 52,857 3 #3/0, 1#6 GIRD - 2"C: MAIN #2 3 PNL "C" 2P -200 50,220 3 #3/0, 1 #6 GIRD - 2" C MAIN #3 4,6 SPACE 2P- G V V FUSE OR DISCONNECT SWITCH • TELEPHONE OUTLET V TELEPHONE OUTLET TV❑ TELEVISION OUTLET �o HI -HAT Dial PUSHBUTTON U V v CHIME • WALL SWITCH 15A, 1.25V TOTAL: THREE WAY TOGGLE SWITCH 157.377 FOUR WAY TOGGLE SWITCH l FIRST 1OKW ® 100% = 10.0 103.42 KW O 40% = 41.37 A/C = 28.60 TOTAL = 79.97 KW (333A) -3 'r MCM THUN (CU) -3 "C (EAa NEMA 3R 229M AIC EMKZ &J" Pte" N LEGEND PNL "A" 32.3 14.3 PNL "B" 30.9 14.3 PNL "C" 50.22 -- 1 13.42 28.6 30510c"CM'103 GRD. T0J4(CU) -3 "C (22Aa00 A.I.C.) � PIM�I. I 15"X15 8X6" J$OX NEMA 3R FOR FUTUIRE LOCATION OF GENERATOR TRANSFER SW. PROVIDE SLACK WIRE INSIDE BOX FOR FUTURE CONNECTION TO TRANSFER SW. AND GENERATOR 1/0 (CU) - 3/4 "C CoPPERCLAD GROUND ROD GWP (METAL) 10 FT. LONG BLDG. STEEL FOUNDATION RISER DIAGRAM NTS M -1 NOTE COMBINATION CARBON MONOXIDE ALARM AND SMOKE DETECTOR SHALL BENR LISTED OR LABELED ELECTRICAL NOTES L ALL ELECTRICAL WOW $HALL 5E IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICAl9LE LOCAL CODES. 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT COMPANY. 3. ALL TELEPHONE RELATED IECUIPMENT PER TELEPHONE CO. AND ANSI/EIA/TIA -510 4. ELECTRICAL INSTALLATION DESIGN OF TH15 PLAN IN IN COM- PLIANCE AS SET FORTH 5Y STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. 5, THE CONTRACTOR WILL EXAMINE THE J05 517E AND DETERMINE FOR HIMSELF P"OR TO 51,15MIS6ION OF 510 EXISTING CONDITIONS. G. ALL ELECTRICAL WORK SHALL Me PERFOFMD 5Y A LICENSED ELECTRICAL CONTRACTOR IT WILL 5E HI8 RESPONS151LITY TO 5ECU1QE AND PAY FOR ANY PEPIMIT6, CERTICATES OF INSPECTION, AS 1111E2UIPED. 1. 51.155TITUTE MATERIALS ECUIP"1"1ENT OR METHODS SHALL NOT 5E MADE WITHOUT APPF40VAL OF THE ENGINEER IF THE USE OF A SU58TITUTE FECUIRES ANY CHANGE IN WOSK THE NECE86ARY FOR SUCH C44ANGE WILL 5E 5F 1OU6vHT TO THE ATTENTION OF THE ENGI- NEER. AND IF AF"PROVED, SHALL 5E MADE AT NO C05T TO THE OWNER 8. CLEAN Le SUCH TRASH AND DE5RI6 GENERATED 5Y THE WORK AND LEAVE COMPLETED WOW IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVIE WTHOUT FOR' ER F" FEPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR A5UTTING UPW TO 5E PEIFOMMM 5Y OTHERS. 10ja00 A.I.C. COMPLY WITH NEC 210.12(5) &-IOI<Z DETECTOR . SWITCH SWITCH LEG I LINE SIDE 120V OF SWITCH M4ASE CONDUCTOR SMOKE DETECTOR CONNECTION DETAIL NT5. rce• LEGEND SPECIAL RECEPTACLE OUTLET • DUPLEX RECEPTACLE OUTLET 15A. 125V WVY SIMPLEX RECEPTACLE OUTLET 15A. 125V O DUPLEX FLOOR RECEPTACLE. 15A. 125V AV EXHAUST FAN • COMBINATION FAN/ LIGHT •i• y CEILING LIGHTING FIXTURE • FLUORESCENT LIGHTING FIXTURE - SURFACE MTD. FO WALL MOUNTED LIGHTING FIXTURE �--`o- -� UNDER CABINET FLUORESCENT LIGHTING FIXTURE (D FLOOD LIGHT 0 CEILING MOUNTED LIGHTING FIXTURE V UGHTING PANEL G V V FUSE OR DISCONNECT SWITCH • TELEPHONE OUTLET V TELEPHONE OUTLET TV❑ TELEVISION OUTLET �o HI -HAT Dial PUSHBUTTON U V v CHIME • WALL SWITCH 15A, 1.25V $3 THREE WAY TOGGLE SWITCH $4 FOUR WAY TOGGLE SWITCH l SAFETY DISCONNECT SWITCH e JUNCTION BOX OF V i FAN OF FAN AND UGHT(3 -WIRE CKT) /L Y GFI GROUND -FAULT INTERRUPTER WP WEATHERPROOF SD SMOKE DETECTOR 4 CARBON •MONOXIDE ALARM W /BATTERY NOTE COMBINATION CARBON MONOXIDE ALARM AND SMOKE DETECTOR SHALL BENR LISTED OR LABELED ELECTRICAL NOTES L ALL ELECTRICAL WOW $HALL 5E IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICAl9LE LOCAL CODES. 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT COMPANY. 3. ALL TELEPHONE RELATED IECUIPMENT PER TELEPHONE CO. AND ANSI/EIA/TIA -510 4. ELECTRICAL INSTALLATION DESIGN OF TH15 PLAN IN IN COM- PLIANCE AS SET FORTH 5Y STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. 5, THE CONTRACTOR WILL EXAMINE THE J05 517E AND DETERMINE FOR HIMSELF P"OR TO 51,15MIS6ION OF 510 EXISTING CONDITIONS. G. ALL ELECTRICAL WORK SHALL Me PERFOFMD 5Y A LICENSED ELECTRICAL CONTRACTOR IT WILL 5E HI8 RESPONS151LITY TO 5ECU1QE AND PAY FOR ANY PEPIMIT6, CERTICATES OF INSPECTION, AS 1111E2UIPED. 1. 51.155TITUTE MATERIALS ECUIP"1"1ENT OR METHODS SHALL NOT 5E MADE WITHOUT APPF40VAL OF THE ENGINEER IF THE USE OF A SU58TITUTE FECUIRES ANY CHANGE IN WOSK THE NECE86ARY FOR SUCH C44ANGE WILL 5E 5F 1OU6vHT TO THE ATTENTION OF THE ENGI- NEER. AND IF AF"PROVED, SHALL 5E MADE AT NO C05T TO THE OWNER 8. CLEAN Le SUCH TRASH AND DE5RI6 GENERATED 5Y THE WORK AND LEAVE COMPLETED WOW IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVIE WTHOUT FOR' ER F" FEPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR A5UTTING UPW TO 5E PEIFOMMM 5Y OTHERS. 10ja00 A.I.C. COMPLY WITH NEC 210.12(5) &-IOI<Z DETECTOR . SWITCH SWITCH LEG I LINE SIDE 120V OF SWITCH M4ASE CONDUCTOR SMOKE DETECTOR CONNECTION DETAIL NT5. rce• ••Y • • ••suu WVY • • • Y V U L • • •i• y • Y r y v u y • y (D U V V V VrrV G V V Li • u V V Y y • i y V•• • • v U V v Y V y • e H U � � • WUV Y Y • Y e Y • V V i • V V' • V V r Y Y V Y • V r Y V • • i • U 4 V V V Y y Y V • V U V • Y • U V • • i • " V V •• W V y V• u Y i u V 4 V V V V i Y r • V V yyuU V V • V V V V GV r r U• Y V W L r V W u V V V NOTES: 1 -5MOKE DETECTOR SHALL BE HARDWIRED (Ilia VOLT TYPE) WITH BATTERY BACK -UP AND SHALL BE CONNECTED TO A BEDROOM CIRCUIT PROTECTED BY AN ARC -FAULT CIRCUIT NTEMPTER. ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE NTERCONNECTED(AFCI PROTECTED) 2 -SMOKE DETECTOR SHALL BE LOCATED AT LEAST 3FT. FROM ANY A/C DIFUSER,BATHROOM DOORS AND WITHIN 20FT. OF COOKING APPLIANCE BE OF A PHOTOELECTRIC TYPE. 3 -THE MOUNTING AND LOCATION OF UNIT SMOKE DETECTORS SHALL COMPLY WITH NFPA 12 SEC2- 5.2.Ib . CEILING MOUNTS NOT LE55 THAN 4" FROM A WALL AND WALL MOUNTS AT LEAST 4" FROM CEILINGS AND NOT MORE THA 12" TO TOP OF DETECTOR S MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH THE RECUIREMENTS OF UNDEFiUIRITERS' LA 5ORATORIES AND SHALL 5E NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC- TURERS REGULARLY ENGAGED M THE PRODUCTION OF THE ITEM, UNLESS OTHOU18E INDICATED. LNCE ITEMS SHALL DE THE PRO- DUCT OF A SINGLE MANILFACTUIRIER 10. ALL CONDUCTOR'S SHALL ME COPPER AND RIN IN CONDUIT. WARE SIZE 51 LL 5E TMN LME68 OTHERWISE NOTED ON PLANS. "RCMDE G kAM CONDUCTOR PER NEC ARTIC 1..E 250 -122. IL LOCATION OR OULET5 IN ELECTRICAL DRAWINGS is DIAGRAMMATIC. CHECK MANFACTURIER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12. I"RCMDE TYrEWRITTEN 15CHEDULE5 FOR ALL PANELI'90ARD6. D. A/C E=IPMENT WIRING, 5REAKER AND RUSE SIZES ARE DA5ED ON A/C ECUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON- TRACTOR IS W&PONSI5LE FOR PROVIDING ALL WIRING, MWAKER AND RISES SIZES N ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE FEWIRE-ENTS IF DIFFIERETIT FROM THAT SPECIFIED ON DRAWINGS, AS UF..L..L AS ANY FEEDER CHANGES 1"3EING AFmCTED 5Y 11-4I5 CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. HACR CIRCUIT 5R EAKERB MAY 5E USED IN PLACE OF FUSES. USE NON - AUTOMATIC SWITCH FOR A✓C COND. DISCONNECT. (COMI"LY WMEC 110 -26) 44. ALL SMOKE OMCTOF4 TO 5E INTERCONNECTED CN SAME CKT (AFCI F'IVOTECTED) 15. RANGE AND DRYER SMALL HAVE BOTH NEUTRAL 4 GROUNDING WIRE PER NEC ARTICLE 2*0 -140. 16. ALL DEDROOM OUTLETS SHALL 5E PROTECTED BY AN 'AFIC -FAULT CIISCUIT NTERRUPTORVAFCI) JOB f: 09 -44 GUERRERO /GONZALEZ ENGINEERS, INC. Michael C. Guerrero. P.E. E Mechanical Eng. Uc. #15235 Pt4f" L Gonzalez, P.E. Electrical " Uc. /11057 •230 Carol Way Miami. norlie 33155 TW. (305) 242 -3944, Fax 305) 262 -8211 E -mall: hROJECTS&GUERR ZALEZENGINEERS.COM CAI 0007 :12 ol U 1� L W J 0 Q Z U 0 1 r 1 tia G g) CV O N rTl W-1 (D Lo C:) CL u © a CII 0 Li rn Y► N 4 C Z Ao U 0 a F� A titiV✓✓ H U � � W A • V 1 Aq 1"'1 Teri 0 00 W 1� o V I C/1 ', e Date: Drawn: MA.S. Checked: RUCs. Proj. No.: Cad File: r JOSE M. REQUEJO FL. RA. 15570 E -3