Loading...
08-1272-051i DUCTWORK LEGEND 24x12 -NEW DUCTWORK, FIRST DIMENSION IS SIDE SHOWN UP DN ---� - CHANGE OF ELEVATION - FLEXIBLE DUCT - TRANSITION, CONCENTRIC - TRANSITION, ECCENTRIC 10x8 - TRANSITION, SQUARE -TO -ROUND - SQUARE THROAT ELBOW W /TURNING VANES - RADIUS ELBOW - RECTANGULAR /ROUND BRANCH TAKE -OFF OR ROUND /ROUND BRANCH TAKE -OFF - MANUAL BALANCING DAMPER - RECTANGLE -TO -ROUND TAKE -OFF - STANDARD BRANCH TAKE -OFF - SPIN -IN TAKE -OFF - CEILING DIFFUSER, ROUND NECK (CEILING DIFFUSERS ARE 4 -WAY THROW UNO) -ROUND DIFFUSER - CEILING RETURN - CEILING EXHAUST FAN - CEILING DIFFUSER, RECTANGULAR OR SQUARE NECK (CEILING DIFFUSERS ARE 4 -WAY THROW UNO) . _ - SUPPLY REGISTER OR GRILLE (VERTICAL MOUNT, SIDEWALL) _ -DOOR GRILLE uC - UNDERCUT DOOR - FLEXIBLE CONNECTION 0 - REVISION REFERENCE e- DETAIL REFERENCE: TOP - DETAIL #, BOTTOM - DRAWING# SHOWN ON O - THERMOSTAT /TEMPERATURE SENSOR F� - CONNECT TO EXISTING - DEMOLISH TO POINT INDICATED i i I n i I t f i i i i GENERAL NOTES: 1.- CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AT JOB SITE PRIOR TO FABRICATION OF DUCTWORK AND PURCHASE OF EQUIPMENT. NOTIFY ARCHITECT /ENGINEER OF ANY SPATIAL COMFLICTS PRIOR TO INSTALLATION, VERIFY ALL CONNECTION TO EQUIPMENT WITH MANUFACTURER'S CERTIFIED DRAWINGS. PROVIDE TRANSITIONS TO ALL EQUIPMENT AS REQUIRED. 2.- FIELD- VERIFY ALL DIMENSIONS AND COORDINATE WITH OTHER TRADES PRIOR TO PROCUREMENT OR FABRICATION. PROVIDE ALL REQUIRED FIELD MODIFICATIONS SUCH AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO OBSTRUCTIONS OR INTERFERENCES AT NO ADDITIONAL COST. FOR PROJECTS INVOLVING RENOVATION, COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, AND ELECTRICAL CONDUIT. 3.- DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC DUCT CONSTRUCTION STANDARD. 4.- PROVIDE AIR TURNING VANES IN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS. 5.- DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT FURNISHED. 6.- COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL CEILING PLANS AND EQUIPMENT OF ALL TRADES. INSTALL ALL AIR DISTRIBUTION OUTLETS /INLETS AT LEAST 12" AWAY FROM WALLS AND CEILINGS TO ALLOW FOR THE INSTALLATION OF CROWN- MOLDINGS WHERE APPLICABLE. 7.- PROVIDE SEVEN DAY PROGRAMMABLE THERMOSTAT FOR ALL AIR CONDITIONING EQUIPMENT. 8.- LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 60" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER EQUIPMENT, FURNITURE, AND DOOR SWINGS. 9.- ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND /OR SPECIFIED. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION -FREE, RIGID INSTALLATION. 10.- ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. 11.- DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE PAINTED FLAT BLACK. 12.- REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT. 13.- TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR PROPER DRAINAGE TO SUIT EQUIPMENT FURNISHED. 14.- ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT. 15.- ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT. 16.- VERIFY MODELS AND FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS AND OTHER AIR DISTRIBUTION DEVICES. 17.- PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO EACH FAN, AIR HANDLING UNITS, AND FAN COIL UNITS. 18.- PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE CONNECTED. 19.- INTERRUPTIONS TO EXISTING SERVICES SHALL BE SCHEDULED FOR TIMES OTHER THAN NORMAL OPERATING HOURS (SUCH AS NIGHTS AND WEEKENDS). SUCH INTERRUPTIONS TO SERVICES SHALL NOT BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF THE OWNER'S REPRESENTATIVE AND PROPER COORDINATION WITH OTHER TRADES. PRE -WORK SHALL BE PERFORMED TO MAKE THE SHUTDOWN PERIOD AS BRIEF AS POSSIBLE. 20.- MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE /SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF RATED WALLS. 21.- DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK. 22.- UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND VALVE DRAINS SHALL BE INDEPENDENTLY PIPED FULL SIZE TO THE NEAREST PLUMBING DRAIN. 23.- EQUIPMENT SPECIFIED SHALL BE ADHERED TO; HOWEVER, OWNER HAS THE FINAL DECISION ON THE TYPE AND QUALITY OF EQUIPMENT TO BE SUPPLIED. CONTRACTOR SHALL OBTAIN WRITTEN PERMISSION FROM THE OWNER PRIOR TO PURCHASING SUBSTITUTING EQUIPMENT. CONTRACTOR SHALL BEAR THE COST OF ALL ENGINEERING WORK RELATED TO SUBSTITUTED EQUIPMENT. 24. FLEXIBLE DUCT SUPPORT AND HANGERS: A.- SUPPORTS: FLEXIBLE DUCTS SHALL BE SUPPORTED AS PER MANUFACTURER'S RECOMMENDED INTERVALS BUT AT LEAST EVERY 5 FT. MAXIMUM PERMISSIBLE SAG IS 1/2" PER FOOT. B.- HANGERS: HANGER AND SADDLE MATERIAL IN CONTACT WITH FLEXIBLE DUCT SHALL BE AT LEAST 1 -1/2" WIDE SO IT DOES NOT REDUCE THE INTERNAL DIAMERTER OF THE DUCT WHEN THE SUPPORTED SECTION RESTS ON THE HANGER OR SADDLE. SADDLES SHALL COVER AT LEAST ONE -HALF (1/2) THE CIRCURFERENCE OF THE OUTSIDE DIAMETER OF THE DUCT AND FIT NEATLY AROUND THE LOWER HALF OF THE OUTER CIRCUMFERENCE. C.- SUSPEND HANGERS FROM BUILDING STRUCTURE AS INDICATED IN THE LATEST SMACNA "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" FIG 4 -2 AND 4 -3 "UPPER ATTACHEMENT DEVICES, TYPICAL" SELECT HANGER AS PER TABLE 4 -2 "MINIMUM HANGER SIZES - ROUND DUCT" EXCEPT THAT MIN. SPACING SHALL BE KEPT AT 5' -0 BETWEEN SUPPORTS 25. DUCTWORK MATERIAL: SUPPLY, RETURN, VENTILATION AND TOILET EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET STEEL CONSTRUCTED IN STRICT ACCORDANCE TO THE LATEST VERSION OF SMACNA. 26. EXPOSED DUCTWORK SHALL BE THROUGHLY CLEANED AND DEGREASED, APPLY TWO (2) COATS OF PRIMER, AND TWO COATS OF FINAL FINISH PAINT. COORDINATE FINAL FINISH WITH ARCHITECT. 27. EXPOSED DUCTWORK SHALL BE INTERNALLY LINED WITH 1" FIBERGLASS INSULATING DUCT LINER EQUAL WITH AN ACRYLIC COATING EQUAL TO JOHNS MANVILLE PERMACOTE LINACOUSTIC. ALL OTHER DUCTWORK SHALL BE INSULATED WITH 1 -1/2" THICK, 1.5 LB DENSITY FIBERGLASS WRAP WITH A REINFORCED ALUMINUM VAPOR BARRIER. 28. KITCHEN EXHAUST DUCTWORK SHALL BE FULLY WELDED STAINLESS STEEL OF MINIMUM 18 GA. MAINTAIN REQUIRED CLEARANCES AS DESCRIBED IN THE FLORIDA MECHANICAL CODE. •WVY V•Y • • •i•Y4+ ri• MOTOR RPM MOTOR HP VOLT/ PHASE PACKAGED ROOFTOP UNIT WEIGHT (LBS) FAN SERVICE EF -1 • • • • • • • • r • • • ' r ` V Y • Y i 400 0.25" DIRECT 817 817 1120 120/1 8.0 35 TOILET ROOMS REFRIG. SUPPLY OUTSIDE EXTERNAL TOTAL SENSIBLE EAT LAT ELEC. EVAP. COND. •�• ••• i V Y • a W V V Y Y ' • UNIT WEIGHT TAG MODEL TYPE Y DdLewisArchitecture +Desigi r Y • • • • • • Y r Y ARD017357 ID0004536 • ♦ • • Y Y • V Y • PHASE Y • • • i Y • Y • • R -410A 2000 100/650 0.65" 77,670 52,200 81.6/69.3 57.4/56.3 • • • 0:0 • • • • • W 19 Q FANS TAG MODEL AIR FLOW (CFM'S) EXT. S.P. DRIVE TYPE FAN RPM MOTOR RPM MOTOR HP VOLT/ PHASE PACKAGED ROOFTOP UNIT WEIGHT (LBS) FAN SERVICE EF -1 • • • • • • • • r • • • ' r ` V Y • Y i 400 0.25" DIRECT 817 817 1120 120/1 8.0 35 TOILET ROOMS REFRIG. SUPPLY OUTSIDE EXTERNAL TOTAL SENSIBLE EAT LAT ELEC. EVAP. COND. COMP. COMP. COMP. UNIT UNIT VOLT/ EER SEER UNIT WEIGHT TAG MODEL TYPE AIR AIR STATIC CAP. (MBH) CAP. (MBH) DB /WB DB /WB HTR, KW FAN HP FAN FLA QTY. LRA RLA MCA MOCP PHASE POUNDS RTU -1 50TC -AQ7 R -410A 2000 100/650 0.65" 77,670 52,200 81.6/69.3 57.4/56.3 9.6 1 -1/2 PLANS 1.5 1 112 19 44 50 230/3 11.2 - 625 RTU -2 50TC -A09 R -410A 2800 800 0.75" 106,260 71,440 81.7/69.1 58.1/57.5 14.7 1 -1/2 2 1 195 29.5 60.6 70 230/3 11.2 - 830 NOTES: SEE FINISH: SEE ARCH DWG LOUVERED RETURN PLANS 1. BASIS OF DESIGN: CARRIER. OTHER ACCEPTABLE MANUFACTURERS: TRANS. 2. PACKAGED ROOFTOP UNITS SHALL BE FURNISHED WITH THE FOLLOWING: CORROSION RESISTANT FACTORY APPLIED PHENOLIC COATED CONDENSOR COILS, FACTORY WIRED 120V GFI OUTLET, 3 VERIFY MOUNTING FRAMES WITH ARCHITECT SINGLE POINT ELECTRICAL CONNECTION, SEVEN DAY PROGRAMMABLE THERMOSTAT, AND CONDENSTAE DRAIN FLOAT SWITCH. 3. SMOKE DETECTORS SHALL BE INSTALLED IN THE SUPPLY DUCTWORK OF RTU'S AND SHALL SHUT DOWN THE UNIT WHEN THE DEVICE IS ACTIVATED. SMOKE DETECTOR SHALL BE TIED INTO THE FIRE ALARM SYSYTEM (WHEN ONE IS PRESENT). 4. PROVIDE ROOFTOP UNITS WITH FACTORY FABRICATED ROOF CURBS. 5. INTERLOCK RTU -1 MOTORIZED OUTSIDE AIR DAMPER WITH KITCHEN HOOD SWITCH. 6. INTERLOCK RTU -2 WITH FOLDING PANEL DOOR TIME DELAY SWITCH. Q FANS TAG MODEL AIR FLOW (CFM'S) EXT. S.P. DRIVE TYPE FAN RPM MOTOR RPM MOTOR HP VOLT/ PHASE SONES WEIGHT (LBS) FAN SERVICE EF -1 H -G -085 -D 400 0.25" DIRECT 817 817 1120 120/1 8.0 35 TOILET ROOMS KEF -1 USGF -180 4200 1.0" BELT 1353 - 1 -1/2 208/1 20 190 KITCHEN HOOD SF -1 KSF- 112 -H20 3360 0,65" BELT 773 - 1 -1/2 208/1 16 250 KITCHEN SUPPLY NOTES: 1. FAN MODEL BASED ON UNIT AS MANUFACTURED BY: GREENHECK 2. INTERLOCK EXHAUST FAN KEF -1 WITH SUPPLY FAN SF -1 AND HOOD SWITCH. 3. PROVIDE A VIBRATION FREE INSTALLATION OF ALL EQUIPMENT. 4. PROVIDE FANS WITH FACTORY ROOF CURBS AND SOLID STATE SPEED CONTROLLERS (DIRECT DRIVE FANS ONLY). 5. ADJUST PULLEY DRIVE SYSTEM TO PROVIDE THE SPECIFIED AIRFLOWS. ASHRAE STANDARD 62 -2004 OUTDOOR AIR REQUIREMENTS FOR VENTILATION A/C UNIT .SIR DISTRIBUTION SCHEDULE AREA (SF) PEOPLE MODEL AIR FLOW DIFF DUCT ACCESSORIES/ KITCHEN TAG DESCRIPTION (CFM) SIZE SIZE CONSTRUCTION A TMS -AA 76 - 115 2424 '� FINISH: SEE ARCH DWG 650 SQUARE CONE 80 - 250 2424 8" Q,B.D.: YES CEILING SUPPLY 251 - 385 24x24 10"0 MATERIAL: ALUMINUM 0.18 781 800 386 - 500 2424 12 "0 ROUND NECK AA TMS -AA 25 -75 12x12 5"0 FINISH: SEE ARCH DWG SQUARE CONE Q,B.D.: YES CEILING SUPPLY MATERIAL: ALUMINUM ROUND NECK B 50F 24x24 SEE FINISH: SEE ARCH DWG 1/2 "x1/2 "x1/2" PLANS DAMPER: YES ALUMINUM EGGCRATE PROVIDELPLENUM. C 272FL SEE SEE SEE FINISH: SEE ARCH DWG DOUBLE DEFLECTION PLANS PLANS PLANS O.B.D.: YES SUPPLY GRILLE MATERIAL: ALUMINUM E 3FL SEE SEE SEE FINISH: SEE ARCH DWG LOUVERED RETURN PLANS PLANS PLANS O g D.: YES MATERIAL: ALUMINUM NOTES: 1 ALL MODELS BASED ON UNITS BY: TITUS 2 VERFIY MODELS AND FINISH WITH ARCHITECT 3 VERIFY MOUNTING FRAMES WITH ARCHITECT ASHRAE STANDARD 62 -2004 OUTDOOR AIR REQUIREMENTS FOR VENTILATION A/C UNIT SPACE AREA (SF) PEOPLE CFM / PERSON CFM / SQ. FT. 0/A REQ'D 0/A PROVIDED RTU -1 KITCHEN 295 3 15 0.18 99 650 TOTALS FIRE STOPPING SMOKE CONTROL 99 650 RTU -2 CAFE DINING 1,005 80 7.5 0.18 781 800 TOTALS 781 800 NOTES: 1- AIRFLOW RATES ARE BASED ON ASHRAE 62 -2004 TABLES. 2- INCREASE IN TOTAL OUTSIDE AIR RATE FOR RTU -1 IS BASED ON MAKE -UP AIR REQUIREMENTS FOR RESTROOMS. HVAC DESIGN REQ YES NO DUCT SMOKE DETECTOR(S) FIRE DAMPER (S) I/ SMOKE DAMPER(S) I� FIRE RATED ENCLOSURE f FIRE RATED ROOF /FLOOR CEILING ASSEMBLY FIRE STOPPING SMOKE CONTROL • • V V www.dblai.us 120 NE 27 ST. # 500 /MIAMI, FL 3313 T 305.572.1220 / Fx ,,305.572.9161 ,. . . to LORENZO`TRIANA,' ;E Florida Registration No.'PE039657 SEAL / SIGNATURE S0M I CAFE PROJECT 4 0204 5200 SW 73 RD ST SOUTH MIAMI, FL 33143 LESSEE: WILLY QUINTANA 301 COLLINS AVE, SUITE 2707 MAIM REACH, FL 33141 F.305.267.7073 STRUCTURAL ENGINEER: THIN - RAMIREZ, 2000 N -W. 29 PL SUITE 102 MAIM I, FL _ ftain @twin- ramirez -com MECH, ELEC, PLUMB, FIRE PROTECT. ENC L.TRIANA is ASSOCIATES, INC CONSULTING ENGINEERS C.A. 26644 9701S.W. 56th St. _ MIAMI, FL 33165 CIVIL ENGINEER: LANDSCAPE ARCHITECT: ILLUSION LANDSCAPE & DESIGN MIAMI, FL LESSOR: ROGER D. SHAY i W. GRACE D 13635 DEERING RAY RD, PH 293 CORAL GABLES, FL 33152 -2212 REVISIONS DATE ISSUE DATE JULY 131 /2009 DWN APPRV DBL Drawing: HVCA LEGEND, NOTE & SCHEDULES Scale: NO SCALE Phase CONSTRUCTION DOCUMENT: Sheet Number: M -1