Loading...
08-1272-050n i r t r i i ELECTRICAL - SYMBOL LEGEND ABBREVIATIONS MOTORS AND CONTROLS AFF ABOVE FINISHED FLOOR /O/ MOTOR. BKR BREAKER SPRING- HINGED, GASKETED AND WEATHERPROOF SAFETY DISCONNECT SWITCH FOR DUCT HEATER C, COND. CONDUIT WITH CONTACTOR. CB. CIRCUIT BREAKER OT THERMOSTAT CKT CIRCUIT O • •• GENERAL NOTES: .�• r.f• GROUNDING TYPE, 20A., 120V., MOUNTED 18" CKT CEILING �] MECHANICALLY HELD CONTACTOR DISC. DISCONNECT & PHOTOELECTRIC CELL EC. EMPTY CONDUIT SURGE PROTECTION DUPLEX RECEPTACLE. 2P., 3 G, GND. GROUND ® LIGHTING RELAY. TWO POLE POWER PACK. WIRED GFI GROUND FAULT INTERRUPTER TYPE, DUPLEX TO LOW VOLTAGE OCCUPANCY SENSOR GFI, GROUND FAULT INTERRUPTER INSTALL THE ELECTRICAL SYSTEMS WITHOUT INTERFERING WITH DUCTS, PIPES, STRUCTURAL STEEL OR OTHER 120V., MOUNTED 18" AFF. LION. HP. HORSE POWER LIGHTING IG ISOLATED GROUND RECEPTACLE 2P., 3 WIRE, GROUNDING TYPE, 20A., DIMENSIONED ON THE DRAWINGS OR LOCATED ON REFLECTED CEILING PLANS. MDP. MAIN DISTRIBUTION PANEL L 02 RECESSED, SEMI RECESSED, SURFACE OR TYPE, 20A., 120V., MOUNTED 18" AFF. LION. PENDANT MOUNTED INCANDESCENT OR H.I.D. MLO, MAIN LUGS ONLY a FIXTURE. L= FIXTURE TYPE., 2= CIRCUIT No. MTD. MOUNTED TWIN DUPLEX RECEPTACLE 2P., 3 WIRE, AND a= SWITCH LEG. PH. PHASE i RECESSED, SEMI RECESSED, SURFACE OR PB. PULL BOX 30A OR 50A, 240V, 1 PHASE, 2P., 3 WIRE, PENDANT MOUNTED INCANDESCENT OR H.I.D- PNL. PANEL FIXTURE ON "LIFE SAFETY CIRCUIT" PWR. POWER RECEPTACLES AND TELEPHONE JACKS 18" O.C. OR (EMERGENCY) SP SURGE PROTECTOR 0 SURFACE OR PENDANT MOUNTED SW. SWITCH CEILING OR WALL MOUNTED JUNCTION BOX FLUORESCENT FIXTURE. TEL. TELEPHONE FL 5. VERIFY CEILING SUSPENSION SYSTEMS IN THE VARIOUS AREAS AND PROVIDE THE PROPER MOUNTING LION. UNLESS OTHERWISE NOTED SURFACE OR PENDANT MOUNTED V. VOLTAGE `a FLUORESCENT FIXTURE ON "LIFE GROUND WIRE. MAXIMUM 3 CIRCUITS PER SAFETY CIRCUIT" (EMERGENCY) W. WIRE zntt>»m HOMERUNS TO PANELS AS SHOWN ON FLOOR W/ WITH PLANS, DO NOT COMBINE HOMERUNS. RECESSED OR LAY -IN FLUORESCENT WP. WEATHER PROOF FIXTURE. XMER TRANSFORMER INDICATES A CONDUIT RUN EMBEDDED IN CONCRETE OR UNDERGROUND. RECESSED OR LAY -IN FLUORESCENT FIXTURE SWITCHES INDICATES AN EXPOSED CONDUIT RUN. ON "LIFE SAFETY CIRCUIT" EMERGENCY) $a SINGLE POLE TOGGLE SWITCH, 20A., 120/277 VAC. (1 WALL MOUNTED INCANDESCENT OR H.I.D. MOUNTED 48" AFF. "a" INDICATES SWITCH LEG. Y FIXTURE 7' -6" AFF. LION. TOGGLE SWITCH, 20A., 120/277 WALL MOUNTED INCANDESCENT OR H.I.D. 3 THREE -WAY lll� FIXTURE ON "LIFE SAFETY CIRCUIT" 7'-6" AFF. VAC. MOUNTED 48" AFF. ABOVE FINISH FLOOR TRASIENT VOLTAGE SURGE SUPPRESSOR UON. (EMERGENCY) UON. I= SAFETY OR DISCONNECT SWITCH �4 FOUR -WAY TOGGLE SWITCH. 20A., 120/277 g CEILING- SURFACE MOUNTED SINGLE FACE EXIT LIGHT FIXTURE WITH ARROWS AS INDICATED. VAC. MOUNTED 48" AFF. LESSEE: EQUAL TO OR GREATER THAN THE RATING OF THE FIRE WALL OR FLOOR THAT THEY PASS THROUGH. USE ONLY D DIMMER SWITCH. MOUNTED 48" AFF. WILLY QUINTANA WALL MOUNTED EXIT LIGHT FIXTURE WITH 301 COLLINS AVE, SUITE 2707 MAIN] BEACH, FL 33141 ARROWS AS INDICATED, 7'-6" AFF. UON. WP WEATHERPROOF TOGGLE SWITCH, 20A. F.305.i67.7073 OBTAIN AND PAY FOR ALL REQUIRED PERMITS, LICENSES, FEES INSPECTIONS, AND POWER COMPANY 120/277 VAC. MTD. 48" A.F.F. _ SURFACE MOUNTED DOUBLE FACE EXIT LIGHT TAIN - RAMIREZ, IN 2000 N.W. 2S PL. FIXTURE WITH ARROWS AS INDICATED. �OR LOW VOLTAGE OVERRIDE SWITCH FOR LIGHTING SUITE 102 11. CUTTING AND PATCHING: PROVIDE ALL CUTTING REQUIRED TO DO THE WORK. DO NOT CUT ANY STRUCTURAL CONTROL PANEL. MOUNTED 48" AFF - WALL MOUNTED DOUBLE FACE EXIT LIGHT $LV LOW VOLTAGE LIGHTING CONTROL SWITCH. Rain twin- ramirez.com FIXTURE WITH ARROWS AS INDICATED. T -6" AFF. MOUNTED 4i" AFF. MECK ELEC, PLUMB, FIRE PROTECT. ENG �OS SINGLE POLE WALL MOUNTED OCCUPANCY L.TRIANA & ASSOCIAI ES, INC WALL MOUNTED EMERGENCY LIGHT FIXTURE SENSOR. 20A., 120/277 VAC. MOUNTED 49" AFF. CONSULTING ENGINEERS C.A.4 26644 WITH EMERGENCY BATTERY PACK 7' -0" AFF. LION. 1201277 9701S.W. 56th St. OS2 SEENSORR OA., VAC. MOUNTED 48" AFF. FIRE ALARM SYSTEM OS SINGLE POLE OCCUPANCY SENSOR. 20A., 1201277 CIVIL ENGINEER: VAC. CEILING - SURFACE MOUNTED n SMOKE DETECTOR CEILING MOUNTED. OS LV LOW VOLTAGE OCCUPANCY SENSOR. SMOKE DETECTOR DUCT MOUNTED. CEILING- SURFACE MOUNTED AND NEMA TYPE 3R FOR OUTDOORS. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL WHERE SHOWN OR 0 CEILING MOUNTED HEAT DETECTOR. COMMUNICATION SYSTEM ❑F MANUAL FIRE ALARM PULL STATION. 48" EQUIPMENT SUPPLIER. ABOVE FINISHED FLOOR. 05 CEILING MOUNTED SPEAKER. SEPARATE NEUTRAL AND GROUND BUSSES. PROVIDE TYPED DIRECTORY CARDS FOR EACH PANELBOARD E4 FIRE ALARM MORN AND FLASHING STROBE WALL MOUNTED SPEAKER. LIGHT 6' -8" ABOVE FINISH FLOOR. TELEPHONE OUTLET (RJ -11) MOUNTED 19" AFF Q FIRE ALARM FLASHING STROBE LIGHT 6'-i" UNLESS OTHERWISE NOTED. PROVIDE %" E.C. TO 1 CORAL GABLES, FL 33152 -2212 CEILING SPACE ABOVE FINISH FLOOR. X DATA BOX "X" DENOTES NUMBER OF DATA FACP FIRE ALARM ZONE ANNUNCIATOR AND PORTS (RJ -45) MOUNTED 18" AFF UNLESS CONTROL PANEL OTHERWISE NOTED. 1" E.C. TO CEILING SPACE p� FIRE ALARM HORN AND FLASHING STROBE a FLOOR MOUNTED COMBINATION TELEPHONE /DATA BOX. LIGHT CEILING MOUNTED COMBINATION TELEPHON / DATA BOX "X" FIRE ALARM HORN, 6'-8" ABOVE FINISHED X,Y DENOTES NUMBER OF DATA PORTS, "Y" FLOOR. DENOTES NUMBER OF TELEPHONE PORTS EWL ELEVATOR WARNING LIGHT PANEL MOUNTED 18" AFF UNLESS OTHERWISE NOTED. 1 " E.C. TO CEILING SPACE QM FIRE ALARM ADDRESSABLE CONTROL OR -� TELEPHONE BACKBOARD (WALL MOUNTED) MONITORING MODULE FCC INTERCOM COMBINATION SPEAKER/ CLOCK STATION, WALL MOUNTED, V -0" AFF. NOTES: 1. ALL DIMENSIONS ARE TO CENTERLINE UNLESS OTHERWISE NOTED. 2. ALL SYMBOLS SHOWN ON ELECTRICAL SYMBOL LEGEND ARE NOT NECESSARILY USED IN THIS PROJECT. RECEPTACLES DUPLEX RECEPTACLE,, 2P., 3 WIRE, GROUNDING t f/ TYPE, 20A., 120V., MOUNTED 18" AFF. LION. WP DUPLEX RECEPTACLE,, AS ABOVE, WITH • U • • • V U U••.i SPRING- HINGED, GASKETED AND WEATHERPROOF U V Y Y V YiiV• Y Y G COVER. DUPLEX RECEPTACLE, , 2P., 3 WIRE, GROUNDING DBLswisArchitsdure +Dez g, TYPE, 20A., 120V., MOUNTED 42" AFF. • • TWIN DUPLEX RECEPTACLE 2P., 3 WIRE, O • •• GENERAL NOTES: .�• r.f• GROUNDING TYPE, 20A., 120V., MOUNTED 18" AFF., LION. 1. ELECTRICAL LAYOUT DRAWINGS ARE PARTIALLY DIAGRAMMATIC. REFER TO ARCHITECTURAL, ST.':'UdTURAL;' *; ISOLATED GROUND TYPE RECEPTACLE. 2P., 3 WIRE, 20A., 125V., MOUNTED 18" AFF. LION. SP SURGE PROTECTION DUPLEX RECEPTACLE. 2P., 3 WIRE 20A., 120V., MOUNTED 18" AFF. UON. (SP DENOTES SURGE PROTECTION) GFI GROUND FAULT INTERRUPTER TYPE, DUPLEX RECEPTACLE 2P., 3 WIRE, GROUNDING TYPE, 20A., INSTALL THE ELECTRICAL SYSTEMS WITHOUT INTERFERING WITH DUCTS, PIPES, STRUCTURAL STEEL OR OTHER 120V., MOUNTED 18" AFF. LION. GFI GROUND FAULT INTERRUPTER TYPE, DUPLEX 120 RECEPTACLE 2P., 3 WIRE, GROUNDING TYPE, 20A., DIMENSIONED ON THE DRAWINGS OR LOCATED ON REFLECTED CEILING PLANS. 120V., MOUNTED 42" AFF. LION. T 305.572.1220 / Fx 305.572.11161 SINGLE RECEPTACLE,, 2P., 3 WIRE, GROUNDING TYPE, 20A., 120V., MOUNTED 18" AFF. LION. NATIONAL ELECTRICAL CODE, THE LATEST RULES AND REGULATIONS OF THE SAFETY ORDERS ISSUED BY THE DUPLEX RECEPTACLE, 2P., 3 WIRE, GROUNDING .•••••.,, •' TYPE, 20A., 120V., FLUSH WITH FLOOR. TWIN DUPLEX RECEPTACLE 2P., 3 WIRE, AND LOCAL CODES ISSUED BY AUTHORITIES HAVING JURISDICTION INCLUDING 2004 FBC WITH 2007 REVISIONS GROUNDING TYPE, 20A., 120V., FLUSH WITH "' a" FLOOR. 30A OR 50A, 240V, 1 PHASE, 2P., 3 WIRE, A GROUNDING TYPE, SINGLE RECEPTACLE ELECTRICAL SURFACE RACEWAYS (DUPLEX RECEPTACLES AND TELEPHONE JACKS 18" O.C. OR YAALA AS DESIGNATED ON DRAWINGS. MOUNTED 36" AFF. LE6tER•TRI,AN T.E. LION. (2) Q CEILING OR WALL MOUNTED JUNCTION BOX (D FLOOR MOUNTED JUNCTION BOX FL 5. VERIFY CEILING SUSPENSION SYSTEMS IN THE VARIOUS AREAS AND PROVIDE THE PROPER MOUNTING WIRING A -1,3,5 HOMERUN TO PANEL "A ".1 -3 -5 ARE CIRCUIT NO's. `a TICKS ARE No. OF CONDUCTORS (� INDICATES GROUND WIRE. MAXIMUM 3 CIRCUITS PER PLANS FOR LOCATIONS, TYPE AND QUANTITY OF CONTROL DEVICES. CONDUIT EACH ON SEPERATE PHASES. RUN zntt>»m HOMERUNS TO PANELS AS SHOWN ON FLOOR PLANS, DO NOT COMBINE HOMERUNS. ELECTRICAL EQUIPMENT INSTALLED AS STATED IN FBC 13- 413.1.ABC.2.2. THE MANUALS SHALL BE SUBMITTED TO INDICATES A CONDUIT RUN CONCEALED IN A CEILING OR WALL. THE BUILDING'S OWNER AND MUST INCLUDED THE FOLLOWING: INDICATES A CONDUIT RUN EMBEDDED IN CONCRETE OR UNDERGROUND. INDICATES A CAPPED CONDUIT. INDICATES AN EXPOSED CONDUIT RUN. -� CONDUIT RUN TURNED DOWN. (RISER DOWN) a CONDUIT RUN TURNED UP. (RISER UP) - ar: ----- CONDUIT SEAL. 7.3. NAMES AND ADDRESSES OF AT LEAST ONE (1) QUALIFIED SERVICE AGENCY. FLEXIBLE CONDUIT ELECTRICAL GROUND DISTRIBUTION EQUIPMENT lll� PANELBOARD. TVS TRASIENT VOLTAGE SURGE SUPPRESSOR FL-R-P-1 LIGHTING RELAY PANEL I= SAFETY OR DISCONNECT SWITCH © ENCLOSED CIRCUIT BREAKER ro•• t f/ ff• • •f• r • U•Ob V V {F• r f • • r 4 U V • r V • U • • • V U U••.i fr♦ •f • ♦ 4 U V Y Y V YiiV• Y Y G - DBLswisArchitsdure +Dez g, • • AR0017357 IDOD04536 O • •• GENERAL NOTES: .�• r.f• Ufa V f • • Y f ; 1. ELECTRICAL LAYOUT DRAWINGS ARE PARTIALLY DIAGRAMMATIC. REFER TO ARCHITECTURAL, ST.':'UdTURAL;' *; • °••• Y••r• �- F VII MECHANICAL AND HVAC DRAWINGS FOR GUIDANCE ON DIMENSIONS, CEILING HEIGHTS, DOOR S�IG£, ROOP9 FINISHES, STRUCTURAL AND ARCHITECTURAL DETAILS, LOCATIONS OF DUCTS, PIPES AND STRUCTUf;ALySTEE!.. ".•.' • :...' INSTALL THE ELECTRICAL SYSTEMS WITHOUT INTERFERING WITH DUCTS, PIPES, STRUCTURAL STEEL OR OTHER www:dblzl.us SYSTEMS. LOCATE LIGHTING SYMMETRICALLY IN PROPER RELATION TO FINISHED AREAS EXCEPT WHERE 120 NE 27 ST. 4 500 /MIAMI, FL 33137 \ DIMENSIONED ON THE DRAWINGS OR LOCATED ON REFLECTED CEILING PLANS. T 305.572.1220 / Fx 305.572.11161 2. THE ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION (2005 NFPA 70) OF THE L/r NATIONAL ELECTRICAL CODE, THE LATEST RULES AND REGULATIONS OF THE SAFETY ORDERS ISSUED BY THE .•••••.,, •' DIVISION OF INDUSTRIAL SAFETY, THE NATIONAL BOARD OF FIRE UNDERWRITERS AND ALL APPLICABLE STATE ••• AND LOCAL CODES ISSUED BY AUTHORITIES HAVING JURISDICTION INCLUDING 2004 FBC WITH 2007 REVISIONS "' a" AND 2003 NFPA -101. "3 3. PROVIDE ADDITIONAL SUPPORTS FOR SWITCHES, PANELBOARDS, RACEWAYS TRANSFORMERS, CABLE TRAYS AND OTHER ELECTRICAL EQUIPMENT WHERE THE BUILDING STRUCTURE IS NOT SUITABLE FOR DIRECT f •,'� t �: MOUNTING. ALL OTHER SUPPORTS AS REQUIRED BY THE NATIONAL ELECTRICAL CODE. LE6tER•TRI,AN T.E. 4. MOUNT GROUPED DEVICES IN A SINGLE CONTINUOUS GANG BOX. USE PARTITIONS WHERE VOLTAGE BETWEEN Florida Registration No: PE065707 SEAL /SIGNATURE EXPOSED LIVE PARTS OF ADJACENT SWITCHES MAY EXCEED 300 VOLTS. 5. VERIFY CEILING SUSPENSION SYSTEMS IN THE VARIOUS AREAS AND PROVIDE THE PROPER MOUNTING ACCESSORIES, TRIMS, ETC. TO SUIT THE PARTICULAR AREA. `a 6. ANY CONDUIT AND BOXES FOR HVAC CONTROL WIRING IS INCLUDED IN THIS SCOPE OF WORK. SEE MECHANICAL H' PLANS FOR LOCATIONS, TYPE AND QUANTITY OF CONTROL DEVICES. zntt>»m 7. MAINTENANCE MANUALS AND INSTRUCTIONS: FURNISH THREE (3) SETS OF OPERATING INSTRUCTIONS FOR ANY ELECTRICAL EQUIPMENT INSTALLED AS STATED IN FBC 13- 413.1.ABC.2.2. THE MANUALS SHALL BE SUBMITTED TO THE BUILDING'S OWNER AND MUST INCLUDED THE FOLLOWING: 7.1. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPERATIONS FOR EACH PIECE OF s 0 n /� I EQUIPMENT REQUIRED MAINTANANCE. v 7.2. OPERATION MANUALS AND MAITENANACE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRED MAINTANANCE. REQUIRED ROUTINE MANITANACE ACTIONS SHALL BE CLEARLY IDENTIFIED. A F E 7.3. NAMES AND ADDRESSES OF AT LEAST ONE (1) QUALIFIED SERVICE AGENCY. PROJECT # 0804 8. ALL ELECTRICAL EQUIPMENT AND INSTALLATION WORK SHALL HAVE A ONE YEAR (1) WARRANTY. FURNISH 5200 SW 73 RD ST WARRANTY SO THE DEFECTIVE MATERIALS AND /OR WORKMANSHIP SHALL BE REPAIRED /REPLACED SOUTH MIAMI, FL 33143 IMMEDIATELY UPON NOTIFICATION AT NO COST TO THE OWNER FOR THE PERIOD OF THE WARRANTY. 9. ANY CONDUIT AND /OR CABLE TRAY PENETRATIONS THROUGH ANY FIRE WALL OR FLOOR SHALL BE FIRESTOPPED LESSEE: EQUAL TO OR GREATER THAN THE RATING OF THE FIRE WALL OR FLOOR THAT THEY PASS THROUGH. USE ONLY WILLY QUINTANA UL APPROVED METHODS AND ASSEMBLIES. RECEPTACLES LOCATED ON OPPOSITE SIDES OF A FIRE BARRIER 301 COLLINS AVE, SUITE 2707 MAIN] BEACH, FL 33141 SHALL BE SEPERATED BY A MINIMUM HORIZONTAL DISTANCE OF 70 ". F.305.i67.7073 OBTAIN AND PAY FOR ALL REQUIRED PERMITS, LICENSES, FEES INSPECTIONS, AND POWER COMPANY STRUCTURAL ENGINEER: 10. PERMITS: AID TO COMPLETE WORK SHOWN. INCLUDE ALL POWER COMPANY COSTS IN BID. TAIN - RAMIREZ, IN 2000 N.W. 2S PL. SUITE 102 11. CUTTING AND PATCHING: PROVIDE ALL CUTTING REQUIRED TO DO THE WORK. DO NOT CUT ANY STRUCTURAL MAIMI, FL ELEMENT WITHOUT APPROVAL. PATCHING SHALL BE OF QUALITY EQUAL TO AND MATCHING APPEARANCE OF Rain twin- ramirez.com EXISTING CONSTRUCTION. DO NOT CUT ANY STRUCTURAL ELEMENT WITHOUT APPROVAL. MECK ELEC, PLUMB, FIRE PROTECT. ENG L.TRIANA & ASSOCIAI ES, INC 12. GROUNDING: ALL PARTS OF THE SYSTEM SHALL BE GROUNDED IN STRICT ACCORDANCE WITH ARTICLE 250 OF CONSULTING ENGINEERS C.A.4 26644 THE NATIONAL ELECTRICAL CODE. 9701S.W. 56th St. M IAM I FL 33165 13. WIRING DEVICES AND PLATES: SWITCHES SHALL BE HUBBELL OR LEVITON 20A 125VOLT AC COMMERCIAL CIVIL ENGINEER: SPECIFICATION GRADE. COLOR WHITE UNLESS NOTED OTHERWISE. USE STEEL COVER PLATES IN UNFINISHED AREAS AND MATCHING PLASTIC COVER PLATES IN FINISHED AREAS. 14. SAFETY SWITCHES: USE HEAVY DUTY TYPE FUSIBLE OR NON - FUSIBLE AS REQUIRED. NEMA TYPE 1 INDOORS AND NEMA TYPE 3R FOR OUTDOORS. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL WHERE SHOWN OR LANDSCAPE ARCHITECT: REQUIRED BY CODE, FUSES: USE DUAL ELEMENT, CURRENT LIMITING, TIME DELAY TYPE OR AS SPECIFIED BY ILLUSION LANDSCAPE& DESIGN EQUIPMENT SUPPLIER. MIAMI' FL 15. PANELBOARDS: USE PANELBOARDS WITH BOLT ON TYPE BREAKERS ONLY. PANELBOARDS SHALL HAVE SEPARATE NEUTRAL AND GROUND BUSSES. PROVIDE TYPED DIRECTORY CARDS FOR EACH PANELBOARD LESSOR: INSTALLED. ROGER D- SHAY 8, W. GRACE D 13635 DEERING BAY RD, PH 293 16. COORDINATION: COORDINATE ALL ELECTRICAL WORK WITH OTHER TRADES AND LOCAL UTILITY COMPANY. CORAL GABLES, FL 33152 -2212 COORDINATE METERING REQUIREMENTS WITH LOCAL ELECTRICAL UTILITY COMPANY. 17. EQUIPMENT: CONNECT ALL ELECTRICALLY OPERATED EQUIPMENT INCLUDING HVAC. USE NEMA 3R DEVICES OUTDOORS. VERIFY LOADS AND LOCATIONS OF EQUIPMENT BEFORE CONNECTION. SIZE BREAKERS, DISCONNECTS, AND FUSES ACCORDING TO THE EQUIPMENT NAMEPLATE. SIZE WIRE ACCORDING TO THE NEC. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REVEIWING THE EQUIPMENT SUPPLIED BY THE MECHANICAL CONTRACTOR AND OTHER TRADES AND SHALL BE RESPONSIBLE FOR MODIFYING THE CONNECTIONS WIRE, DISCONNECTS, BREAKERS, ETC. SHOWN ON THE DRAWINGS IN ORDER TO MAKE A REVISIONS DATE COMPLETE INSTALLATION AND TO SATISFY THE MANUFACTURER'S REQUIREMENTS. THE ELECTRICAL CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIALS TO COMPLETE THE INSTALLATION. 18. RECORD DRAWINGS: MAINTAIN A RECORD SET OF ALL CHANGES DURING CONSTRUCTION. RECORD CHANGES ON A CLEAN SET OF CONTRACT CONSTRUCTION DOCUMENTS WHICH SHALL BE TURNED OVER TO THE OWNER WITH IN 30 DAYS OF COMPLETION. RECORD DRAWINGS SHALL INCLUDED A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION AS PER FBC 13- 413.1.ABC.2.1. 19. IDENTIFICATION: IDENTIFY ALL MAJOR PIECES OF ELECTRICAL EQUIPMENT INSTALLED ON THE PROJECT. EXAMPLES INCLUDE PANELBOARDS, MOTOR STARTERS, DISCONNECTS, AND CONTROL PANELS. IDENTIFY WITH PERMANENT PLASTIC NAMEPLATES. 20. THE CONTRACTOR, PRIOR TO BIDDING, SHALL VISIT THE JOB SITE TO BECOME ACQUAINTED WITH THE EXISTING INSTALLATION AND SYSTEMS RELATED TO THE WORK AND SHALL INCLUDE IN THE BID PROPOSAL ALL LABOR AND MATERIALS REQUIRED FOR THE ELECTRICAL INSTALLATION TO BE COMPLETE AND OPERATIVE. 21. THE CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS IN THE FIELD BEFORE COMMENCEMENT OF THE WORK AND SHALL REPORT ANY DISCREPANCIES AND /OR INCONSISTENCIES BETWEEN THE DRAWING AND EXISTING FIELD CONDITIONS TO THE ENGINEER FOR CLARIFICATIONS BEFORE COMMENCEMENT OF WORK. 22. ALL FEEDER AND BRANCH CIRCUIT CONDUITS SHALL BE INSTALLED CONCEALED IN FINISHED AREAS, UNLESS OTHERWISE NOTED. 23. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS. 24. UPON COMPLETION OF HIS WORK, THE CONTRACTOR SHALL SCHEDULE AND PERFORM A COMPLETE FUNCTIONAL TEST TO DEMONSTRATE TO THE OWNER THAT THE NEW INSTALLATION IS OPERATING AS INTENDED. ANY DEFECTS OR DEFICIENCIES IN THE MATERIALS OR INSTALLATION WORK SHALL BE CORRECTED IMMEDIATELY BY AND AT THE CONTRACTOR'S EXPENSE. WORKMANSHIP SHALL BE OF THE HIGHEST QUALITY. Lu W ISSUE DATE JULY /31/2002 25. ALL ELECTRICAL EQUIPMENT SHALL BE NEW, U.L. LISTED AND APPROVED FOR INTENDED USE. DWN APPRV DdL 26. ALL ELECTRICAL EQUIPMENT EXPOSED TO WEATHER SHALL BE WEATHERPROOF. w Drawing: r J 27. PROVIDE MINIMUM 10 FEET SLACK CONDUCTOR FOR SPARE WIRING INSIDE WIREWAYS OR PULLBOXES. J NOTES, LEGEND 28. ALL CONDUCTORS SHALL BE THWN COPPER UNLESS OTHERWISE SPECIFIED. GREEN INSULATED GROUND o Scale: CONDUCTORS SHALL BE INSTALLED IN ALL FEEDER AND BRANCH CIRCUIT WIRING CONDUITS. ALL INTERIOR CONDUITS SHALL BE EMT. ALL EXTERIOR AND UNDERGROUND CONDUITS SHALL BE PVC SCHDEULE 40. PLASTIC Lu /4" @24X36 TYPE CONDUITS ARE NEVER TO BE USED IN AN AIR RETURN PLENUM. REFER TO MECHANICAL DRAWINGS. rPh2Se 29. WHERE THE LENGHT OF A HOMERUN, FROM PANEL TO FIRST CIRCUIT, EXCEEDS 75 FEET FOR A 120 VOLT cn cn CIRCUIT OR 175 FEET FOR A 277 VOLT CIRCUIT, THE CONDUCTOR SIZE: PROVIDE #10 AWG. CONSTRUCTION DOCUMENT; 30. CONTRACTOR SHALL VERIFY FLOOD CRITERIA LEVEL BEFORE ORDERING ANY EQUIPMENT OR COMMENSING ANY ° Sheet Number: WORK. ELECTRICAL INSTALLATION MUST BE ABOVE FLOOD CRITERIA. 8 N © �_6 C7