08-1272-009`rte I
RM
NAME
MIN,
RATING
CEILING
ASSAMB
LY REQ,
101
ENTRANCE
1HR
102
LOUNGE
1HR
103
BAR
1HR
104
DINING
1HR
105
SERVER
1HR
106
COLD STORAGE
1HR
107
KITCHEN
1HR
108
MEN RESTRM
1HR
109
WOMEN RESTRM
1HR
110
CORRIDOR
1HR
111
N,C❑URTYARD
1HR.
112
E, COURTYARD
1HR
-- .,._ -- - 4 - - - -- - - - -- - -� - - --r -- r7KO
--I -- - - - -,,
LAM
\
1 � -
°i
v ..
II
I �111 � X E I ., �
w
1 7
K CHEN ! �I n
r -� �
�s•1''
� �, ; of
2. DOORS AND FRAMES IN ONE (1) HOUR WALLS: SHAFT, EXIT ENCLOSURE, EXIT
PASSAGEWAY SHALL BE C LABEL, 45 MINUTES RATED. (SEE DOOR SCHEDULE)
3. DOORS AND FRAMES IN ONE (1) HOUR FIRE PARTITION CORRIDOR WALLS ,
SHALL BE 20 MINUTES RATED.
3. DOORS AND FRAMES IN 30 MINUTE WALLS SHALL RE 20 MINUTES RATED.
a � y,i. �•Sl.f'
4. DOORS AND FRAMES IN THREE (3) HOUR WALLS SHALL BE A LABEL,
'
,3 HOUR 'A' LABEL DOOR WITH SELF - CLOSING DEVICE
6 2 HOUR 'I' LABEL DOOR WITH SELF -CL ❑SING DEVICE
C 1 HOUR 'C' LABEL DOOR WITH SELF - CLOSING DEVICE.
20 1/3 HOUR RATED LABEL DOORWITH SELF -CL ❑SING DEVICE
z� 1/3 HOUR RATED DOOR WITH SELF -CL ❑SING DEVICE
FIRE EXTINGUISHER LEGEND
LOCATION
MINIMUM RATING
AREAIUNIT OF
1
MINIMUM OCCUPANT LOAD: (RESTAURANT)
FIRE DOOR LEGEND NFPA 101 2006 LIFE SAFETY CODE TABLE 8,3,42
1, DOOR B FRAMES IN TWO (2) HOUR WALLS SHALL BE B LABEL, 40 MINUTE RATED.
(SEE DOOR SCHEDULE)
2. DOORS AND FRAMES IN ONE (1) HOUR WALLS: SHAFT, EXIT ENCLOSURE, EXIT
PASSAGEWAY SHALL BE C LABEL, 45 MINUTES RATED. (SEE DOOR SCHEDULE)
3. DOORS AND FRAMES IN ONE (1) HOUR FIRE PARTITION CORRIDOR WALLS ,
SHALL BE 20 MINUTES RATED.
3. DOORS AND FRAMES IN 30 MINUTE WALLS SHALL RE 20 MINUTES RATED.
(SEE DOOR SCHEDULE)
4. DOORS AND FRAMES IN THREE (3) HOUR WALLS SHALL BE A LABEL,
180 MINUTES RATED.
,3 HOUR 'A' LABEL DOOR WITH SELF - CLOSING DEVICE
6 2 HOUR 'I' LABEL DOOR WITH SELF -CL ❑SING DEVICE
C 1 HOUR 'C' LABEL DOOR WITH SELF - CLOSING DEVICE.
20 1/3 HOUR RATED LABEL DOORWITH SELF -CL ❑SING DEVICE
z� 1/3 HOUR RATED DOOR WITH SELF -CL ❑SING DEVICE
FIRE EXTINGUISHER LEGEND
LOCATION
MINIMUM RATING
AREAIUNIT OF
1
MINIMUM OCCUPANT LOAD: (RESTAURANT)
RATING/TRAVEL DISTANCE
MACHINE Q ELECTRIC
2A 109 C
3,000 SF / 30 FT
OFFICE AREAS
2A
3,000 SF / 75 FT
PUBLIC AREAS
2A
1,500 SF / 75 FT
PARKING GARAGE
2A
1,500 SF / 75 FT
MINIMUM EGRESS CODE REQUIREMENTS (GROUP A -2):
NON - SPRINKLER BUILDING
MAXIMUM TRAVEL DISTANCE (FBC TABLE 1015.1)
150' -0"
MAXIMUM DEAD END CORRIDOR (FBC 1016.3)
20' -0"
EGRESS WIDTH PER PERSON SERVED (IN.) LEVEL (FBC TABLE 1005.1)
0.2
EGRESS WIDTH PER PERSON SERVED (IN.) STAIRS (FBC TABLE 1005.1)
0.3
MINIMUM CORRIDOR /AISLE WIDTH (IN.) (FBC 1016.2)
44"
MINIMUM CLEAR OPENING OF EXIT DOORS (IN.) (FBC 1008.1.1)
32"
MINIMUM STAIR WIDTH (IN.) (FBC 1009.1)
44"
COMMON PATH OF TRAVEL (FBC 1030.3)
20' -0 "- UNLIMITED OCCUPANTS 75' -0 "- NOT MORE THAN 50 OCCUP.
MINIMUM NUMBER OF EXITS, (FBC TABLE 1018.1)
1 -500 OCCUPANTS: 2 501 -1,000 OCCUPANTS:3
COORIDOR RESISTANCE RATING 1(FBC TABLE 1016.1)
1
MINIMUM OCCUPANT LOAD: (RESTAURANT)
UNCONCENTRATED
15 SF NET
OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. THE FORCE
REAMS, GIRDERS, TRUSSES, A
1 HOUR
ARCHES:
MINIMUM EGRESS CODE REQUIREMENTS (GROUP 13):
MAXIMUM TRAVEL DISTANCE (FBC TABLE 1015.1)
200' -0"
MAXIMUM DEAD END CORRIDOR (FBC 1016.3)
20' -0"
EGRESS WIDTH PER PERSON SERVED (IN.) LEVEL (FBC TABLE 1005.1)
0.2
EGRESS WIDTH PER PERSON SERVED (IN.) STAIRS (FBC TABLE 1005.1)
0.3
MINIMUM CORRIDOR /AISLE WIDTH (IN.) (FBC 1014.2)
44"
MINIMUM CLEAR OPENING OF EXIT DOORS (IN.) (FBC 1004.1.1)
32"
MINIMUM STAIR WIDTH (IN.) (FBC 1004.1)
44"
COMMON PATH OF TRAVEL (FBC 1027)
100' -0"
MINIMUM NUMBER OF EXITS, (FBC TABLE 1014.1)
1 -500 OCCUPANTS: 2 501 -1,000 OCCUPANTS:3
COORIDOR RESISTANCE RATING 1(FBC TABLE 1016.1)
1
MINIMUM OCCUPANT LOAD:
BUSINESS AREAS I 1 PER 100 G.S.F.
BASED ON FIRE SEPARATION DISTANCE
MINIMUM OCCUPANT LOAD GROUP S:
STORAGE, ARCHIVE AREAS 1 PER 300 G.S.F.
1 3/4
<51
FLAME SPREAD RATINGS OF AREAS
AREA
MIN. INT. FIN. CLASSIFICATION
EXITS
25
EXIT ACCESS
25
OTHER SPACES
75
OCCUPANCY SEPARATION REQUIREMENTS:
ASSEMBLY: (FRC 302.3.1 )
0 HOUR NON - SEPARATED USE
BUSINESS: (FBC 302,3,1)
0 HOUR NOWSEPARATED USE
STORAGE S -1 FBC 302.3.1:
0 HOUR NON - SEPARATED USE
MINIMUM FIRE RESISTANCE OF WALLS,
PARTITIONS AND OPENING PROTECTIVES:
SHAFT ENCLOSURES (INCLUDING STAIRWAYS, EXITS i ELEVATORS):
1 HOURS (CONNECTING LESS THAN 4 STORIES)
SHAFT ENCLOSURE:
1 HOURS (CONNECTING 2 STORIES)
VERTICAL SHAFTS:
1 HOURS (CONNECTING 2 STORIES)
ELECTRICAL ROOM:
2 HR
MECHANICAL ROOM:
1 HR
SPRINKLER SYSTEM NOTES: c•��
:•...
BUILDING IS NON - SPRINKLE
2. CONCRETE MASONRY UNITS USED IN EXTERIOR WALLS AND IN ALL WALLS OR PARTITIONS SHALL COMPLY WITH ASTM C90 B C129 PER
BUILDING DATA:
OCCUPANCY GROUP:
A -2 ASSEMBLY RESTAURAN
SUB - OCCUPANCY GROUP:
N/A
CONSTRUCTION TYRE:
TYPE 1113 EXISTING
EXISTING BUILDING ALTERATION: -
LEVEL 2 PER FRC
ALLOWABLE HEIGHT:
2 STORYS (TABLE 503 FBC)
ALLOWABLE BUILDING AREA:
9,058 SF
EXISTING BUILDING AREA:
1,859.38 SF
MAX. ALLOWABLE FIRE AREA:
9,500 SF (TABLE 503 FBC)
FIRE RESISTANCE RATINGS FOR BUILDING
ELEMENTS (TYPE IIIB CONSTRUCTION): FBC TABLE $01
STRUCTURAL FRAME: COLUMNS,
OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. THE FORCE
REAMS, GIRDERS, TRUSSES, A
1 HOUR
ARCHES:
SECTION 1012.1.11, SECTION 1012.2.2., SECTION 1012.4, A SECTION 1012.6.
EXTERIOR BEARING WALLS:
2 HOURS
INTERIOR BEARING WALLS:
1 HOUR
NON - BEARINGEXTERIOR WALLS k
SEE CHART BELOW
PARTITIONS:
12. COMBUSTIBLE MATERIALS SHALL NOT BE USED IN CONCEALED SPACES EXCEPT AS ALLOWED IN FBC 707.1
NON - BEARING WALLS i PARTITIONS
1 HOUR
INTERIOR:
TABLE 715.4 FBC
FLOOR I FLOOR / CEILING
1 HOUR
ASSEMBLIES:
REQ'D ASSEMBLY RATING (HRS)
ROOFS Q ROOFS / CEILING
1 HOUR
ASSEMBLIES:
NP
ALL EXISTING EXPOSED PRIMARY STRUCTURAL ELEMENTS TO BE COVERED WITH 1 HOUR RATED FIRE PROTECTION
FIRE RESISTANCE RATINGS FOR EXTERIOR WALLS
BASED ON FIRE SEPARATION DISTANCE
(TYPE IIIB CONSTRUCTION):
EXTERIOR WALLS:
1 3/4
<51
3 HOURS '
>5'toa10'
2HOURS
> 10' to a 20'
2 HOURS
>20' TO a 30'
1 HOUR
OVER 30' -0 ":
0 HOUR
MAXIMUM AREA OF EXTERIOR WALL OPENINGS:
EXTERIOR WALLS PROTECTED:
9 OCCUPANTS
0' -0" TO 3' -0" TO PROP. LN,:
NOT PERMITTED
OVER 3' -0" TO 5' -0 ":
10% OPENINGS
OVER 5' -0" TO 10' -0 ":
15% OPENINGS
OVER 10' -0" T015' -0 ":
45% OPENINGS
OVER 15' -0" TO 20'
75% OPENINGS
EXTERIOR WALLS UNPROTECTED:
0' -0" TO T -0" TO PROP. LN.:
NOT PERMITTED
OVER 3' -0" TO 5' -0 ":
NOT PERMITTED
OVER 5' -0" TO 10' -0 ":
10% OPENINGS
OVER 10' -0" T015' -0 ":
15% OPENINGS
OVER 15' -0" TO 20'
25% OPENINGS
U Y 1' 7T U l
r r
•1• , •r't
NOTES:
1, ALL DRY WALL INTERIOR PARTITIONS SHALL BE INSPECTED BY THE BUILDING DEPARTMENT EXCEPT FOR THE INTERIOR SOFFITS WHICH
SHALL RE INSPECTED BY THE SPECIAL INSPECTOR.
2. CONCRETE MASONRY UNITS USED IN EXTERIOR WALLS AND IN ALL WALLS OR PARTITIONS SHALL COMPLY WITH ASTM C90 B C129 PER
FLORIDA BUILDING CODE',ECTION 703.7.
3. PER FLORIDA BUILDING CODE SECTION 704.2.1.4, CORRIDOR PARTITIONS, SMOKESTOP PARTITIONS, HORIZONTAL EXIT PARTITIONS,
EXIT ENCLOSURES, AND FIRE RATED WALLS REQUIRED TO HAVE PROTECTED OPENINGS SHALL RE EFFECTIVELY AND PERMANENTLY
IDENTIFIED WITH SIGNS OR STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. SUCH IDENTIFICATION
SHALL BE ABOVE ANY DECORATIVE CEILING AND IN CONCEALED SPACES. SUGGESTED WORDING:
"FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS ".
4. PER FLORIDA BUILDING CODE SECTION 412.10.1, AN APPROVED COMPLETE AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED
THROUGHOUT THE BUILDING. THE SPRINKLER SYSTEM SHALL BE DESIGNED USING THE PARAMETERS SET FORTH IN NFPA 13.
S. PER FLORIDA BUILDING CODE SECTION 412.10.2, SHUTOFF VALVES AND WATER FLOW DEVICES SHALL RE PROVIDED AT THE RISER
CONNECTION ON EACH FLOOR. THE ACTUATION OF A WATER FLOW DEVICE SHALL ACTIVATE THE VOICE ALARM SYSTEM. THE VALVES
SHALL RE SUPERVISED IN ACCORDANCE WITH SECTION 903.9, THE SPRINKLER RISER MAY BE COMBINED WITH THE FIRE DEPARTMENT
STANDPIPE RISER,
4. PER FLORIDA BUILDING CODE SECTION 705.1.2.2.1, FIRE DAMPERS, INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION
INSTRUCTIONS, SHALL RE PROVIDED IN DUCTS PENETRATING WALLS OR PARTITIONS HAVING A FIRE RESISTANCE OF 1 HOUR OR
MORE,
7. PER FLORIDA BUILDING CODE SECTION 705.1.2.2.2, FIRE DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF UL 555 AND SHALL
BEAR THE LABEL OF AN APPROVED TENSING AGENCY. CLOSURE SHALL INTERRUPT ANY MIGRATORY AIR FLOW AND RESTRICT THE
PASSAGE OF FLAME, FIRE DAMPERS SHALL BE CLASSIFIED AND IDENTIFIED FOR USE AS EITHER STATIC SYSTEMS THAT
AUTOMATICALLY SHUT DOWN IN THE EVENT OF FIRE, OR DYNAMIC SYSTEMS THAT OPERATE IN THE EVENT OF FIRE.
8. PER FLORIDA BUILDING CODE SECTION 1012.1.6, DOOR HANDLES, FULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL BE
OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. THE FORCE
REQUIRED TO OPERATE THE CONTROLS SHALL RE NO GREATER THAN 5 LBF (22N), WITH THE EXCEPTION OF DOORS WITHIN OR
SERVING A SINGLE DWELLING UNIT NOT REQUIRED BE ACCESSIBLE BY CHAPTER 11.
4. CONTRACTOR IS TO COMPLY WITH FLORIDA BUILDING CODE SECTIONS 1012.1.7, SECTION 1012.1.8, SECTION 1012.1.4, 1012.1.10,
SECTION 1012.1.11, SECTION 1012.2.2., SECTION 1012.4, A SECTION 1012.6.
10. AT SOUTH WALL DISTANCE TO PROPERTY LINE IS V -6 ".
PERMITTED PERCENTAGE OF OPENINGS IN WALL: 10% OF TOTAL WALL AREA (T.W.A. = 8,477 SF, 10 %= 847.7. S.F.)
PROVIDED PERCENTAGE OF UNPROTECTED OPENINGS IN WALL: 735.7 SF m 4.2'/.
PROVIDED PERCENTAGE OF PROTECTED OPENINGS (WITH SPRINKLER HEADS) IN WALL: 739.4 SF = 8.5%
FLORIDA BUILDING CODE RE: TABLE 400 FIRE RESISTANCE RATINGS REQUIRED FIRE RESISTANCE IN HOURS; EXTERIOR NON - BEARING
WALLS 3 FT TO 10 FT SEPARATION FROM PROPERTY LINE = 10'/.
11. COMBUSTIBLE MATERIALS SHALL NOT BE USED INSIDE THROUGH FIRE RATED ASSEMBLIES EXCEPT AS ALLOWED IN FBC 706.1
12. COMBUSTIBLE MATERIALS SHALL NOT BE USED IN CONCEALED SPACES EXCEPT AS ALLOWED IN FBC 707.1
13. USE A ONE -WAY VOICE ALARM SYSTEM AND A TWO -WAY FIRE DEPARTMENT COMMUNICATION SYSTEM, INSTALLED IN ACCORDANCE
WITH NFPA 72, FBC 412.3
WINDOW ASSEMBLY FIRE PROTECTION RATINGS
TABLE 715.4 FBC
TYPE OF ASSEMBLY
REQ'D ASSEMBLY RATING (HRS)
MIN. FIRE WINDOWASSEMBLY RATING (HRS)
INTERIOR FIRE WALL
ALL
NP
INTERIOR FIRE BARRIER/PARTITION
> 1
NP
INTERIOR FIRE WALL
11
1 3/4
SMOKE BARRIER
11
1 314
OCCUPANCY LOAD CALCULATIONS:
LOCATION
ASSEMBLY
KITCHEN
STORAGE
TOTAL PER AREA
INTERIOR
44 OCCUPANTS
9 OCCUPANTS
2 OCCUPANTS
80 OCCUPANTS
EXTERIOR
72 OCCUPANTS
72 OCCUPANTS
OVERALLTOTAL
152 OCCUPANTS