08-1272(2)-023
Iffil M to rt 0 r- SYSTEM GROUNDING NOTE TYPE: LOADCENTER BUS RATING: 400 A ONE OF THE MOST IMPORTANT PARTS IN THE INSTALLATION OF PHASE A (AMFOS) ELECTRICAL SYSTEMS IS GROUNDING. PROPER GROUNDING WILL PHASE C (AMPS) PROVIDE PROTECTION OF PERSONNEL, EQUIPMENT, AND CIRCUITS 202,10 185.98 BY ELIMINATING THE POSSIBILITY OF DANGEROUS OR EXCESSIVE 15040 135,98 VOLTAGES. 234.50 * GROUNDING SYSTEM MUST BE IN ACCORDANCE WITH IDENTIFICATION APPLICABLE NATIONAL, STATE OR LOCAL ELECTRICAL 44.0 CODES. * THE GROUND PATH MUST BE PERMANENT AND 2 CONTINUOUS, AND THE RESISTANCE OF THE GROUND CONNECTION TO COLD PATHS MUST NOT EXCEED TWO OHMS. WATER PIPE MUST BE MADE AC -RTU WITHIN 5 FT OF POINT OF * ALL GROUNDING ELECTRODES OF DIFFERENT SYSTEMS ENTRANCE OF PIPE MUST BE BONDED TOGETHER. 'B' * METALLIC CONDUIT USED TO ENCLOSE A GROUNDING #6 - 1"C CONDUCTOR MUST BE BONDED TO THE GROUNDING 4 CONDUCTOR AT BOTH ENDS TO REDUCE IMPEDANCE. BONDING JUMPER (TYP) * RECEPTACLE BOXES MUST BE GROUNDED BY RACEWAY BACK TO THE GROUNDED PANEL. * IF FLEXIBLE OR PVC CONDUIT IS USED, OR WHERE 6 REQUIRED BY LOCAL CODE, THEN A SEPARATE MECHANICAL #4 - 1 "C T1 MAIN: M.L.O. GROUND WIRE MUST CONNECT THE OUTLET BOX TO THE #12-%"C ISOLATED GROUND PANEL PANEL MECHANICAL GROUND BUS. NEUTRAL: FULL IDENTIFICATION TERMINATE 6" ABOVE ACCESSIBLE CEILING (TYPICAL) 3/" WIRING SHALL CONFORM TO THE REGULATIONS OF NEC ARTICLE 900 (TYPICAL) #6 (Cu) "6" x 36 x' /" TEL. BOARD 'AINT WITH BLACK FIRE :ETARDANT PAINT 'ROVIDE 2 -3" E.C. '0 NETWORK SWITCH IOUNT RECEPTACLE IIRECTLY ON BOARD �.W. , W ," LEPHONE GOMPANY POINT OF CONNECTION. CONTRACTOR SHALL COORDINATE DIRECTLY. TELEPHONE SYSTEM RISER DIAGRAM N.T.S. SERVICE ENTRANCE CONDUCTORS. METAL FRAME OF BUILDING FOR EXACT SIZE REFER TO ELECTRICAL RISER DIAGRAM II /-- SERVICE ENTRANCE EQUIPMENT NEUTRALBUS MAIN BONDING JUMPER GROUNDBUS GROUNDING ELECTRODE CONDUCTOR. FOR EXACT SIZE REFER TO RISER DIAGRAM CONCRETE ENCASED ELECTRODE L-- -METAL UNDERGROUND COLD GROUND RING TWO (2) 5/8" x 10' -0" WATER PIPE. DIRECT CONTACT LONG GROUND RODS WITH THE EARTH FOR 10 FT (MIN) SPACED 6' -0" APART GROUNDING ELECTRODE SYSTEM DETAIL N.T.S. ISOALTED GROUND NOT CONNECTED TO RECEPTACLE FRAME 0 �-0 O ISOLATING BARRIER - CONNECTION POINT FOR ISOLATED GROUNDS FROM OTHER "IG" RECEPTACLES ON THIS CIRCUIT, ,, ---r- ENCLOSURE GROUND GROUNDING ELECTRODE ISOLATED GROUND INSTALLATION DETAIL N.T.S. PNL'A' mammaen r... I� PNL'B' e� L II © ii it I i MAIN 1/2 I I Ii II MAIN 2/2 I I I II III II II II I I ELECTRICAL RISER DIAGRAM N.T.S. SERVICE LOAD CALCULATION TYPE: LOADCENTER BUS RATING: 400 A LOAD PHASE A (AMFOS) PHASE ■ (AMPS) PHASE C (AMPS) PANEL'A' PANEL'D' 202,10 185.98 234.50 0.00 15040 135,98 TOTALS: 383.08 234.50 376.73 I RISER NOTES: 1. EXISTING ELECTRIC METER IN NEMA3R ENCLOSURE RATED 400A TO REMAIN. 2. EXISTING 3P -400A NEMA3R FUSIBLE SWITCH. PROVIDE (3) THREE NEW 300A FUSES RATED FOR 65KAIC. LABLE MAW 1 OF 2. 3. EXISTING 2P -200A NEMA3R FUSIBLE SWITCH. PROVIDE (2) TWO NEW 200A FUSES RATED FOR 65KAIC. LABLE MAIN 2 OF 2. 4. PROVIDE NEW 12"x 12" LINE GUTTER NEMA3R RATED. 5. PANEL'S'. PROVIDE ISOLATED GROUND BUS. FOR CHARACTERISTICS SEE SCHEDULE 6. PANEL'A' FOR CHARACTERISTICS SEE SCHEDULE 7. BUILDING GROUNDING SYSTEM. REFER TO DETAIL THIS SHEET FEEDER SCHEDULE A. SERVICE ENTRANCE CONDUCTORS: TWO SETS OF 3 #310 + 1 #1/0 HI -LEG THWN (Cu) EACH IN 2" C TO FPL. CONTRACTOR SHALL COORDINATE DIRECTLY WITH FPL PRIOR TO COMMENCING ANY WORK. B. 2 SETS OF 4#/1/0 THWN (Cu) EACH IN 2"C C. 3 #3/0 THWN (Cu) IN 2" C D. 3#3/0 + 1 #6 THWN (Cu) IN 2"C E. 2 SETS OF 4 #1/0 + 1#4 G THWN (Cu) EACH IN 2" C F. #2 (Cu) GROUNDING ELECTRODE IN 1" C TO GROUNDING SYSTEM. SEE DETAIL THIS SHEET, G. REMOVE EXISTING FEEDERS AND CONDUITS. H. 1#4 GROUNDING ELECTRODE IN 1" C TO GROUNDING SYSTEM. TIE TO ISOLATED GROUND BUS IN PANEL'B' sees ••• • • •• :a• ••a see 0 se: ••• r • : •see • r • • a w • • •i• s•v• sear: eer r••• • u r [+ 4 w • ! • Y • hoer • 00000 • •re • seer 4 MANUFACTURER: SIEMENS TYPE: LOADCENTER BUS RATING: 400 A MOUNTING: FLUSH PANEL 'A' MAIN: M.L.O. BREAKERS:10KAIC NEUTRAL: FULL IDENTIFICATION A *B C WIRE TRIP CKTCKT TRIP VOLTAGE: 120/240 VAC 10 3W TYPE: LOAD CENTER IDENTIFICATION 44.0 #6 - 1 "C 1 2 #4 -1 "C 60.6 BUS RATING: 200 A AC -RTU • 44.0 3P -50A 3P -70A PANEL 'B' AC -RTU #6 - 1"C 3 4 MOUNTING, FLUSH 44.0 • 60.6 11.0 #6 -1 "C 6 6 #4 - 1 "C MAIN: M.L.O. BREAKERS: 10KAIC #12-%"C ISOLATED GROUND PANEL 8 NEUTRAL: FULL IDENTIFICATION A B WIRE TRIP CKTCKT TRIP WIRE A B IDENTIFICATION REF. PIZZA PREP #8 (8) 0.95 j #12 -' /2"C 1P -20A 1 2 11P-20A X12 -1/2"C 11.0 15.0 • 1.80 SPACE LIGHTING (1) HOOD FIRE SUPPRESSION ##1.1 (8) 0.10 #12 -1/2"C 1P -20A 3 4 1P -20A X12 -' /2 "C ICE MAKER #18 1.65 LIGHTING (1) REFRIGERATOR, SHORTY #4.1 (8) 1.20 • 15.0 #12 -' /2 "C 1P -20A 5 6 1P -20A #12 -1/2"C #12 -% "C 0.70 10.8 25.0 LIGHTING (1) REF. UNDERCOUNTER 06 (8) 0.70 #r`12 -' /�'C 1P -20A 7 9 1P -20A *12 -'Y2 "C #12 - % "C 0.80 LIGHTING (1) REF. UNDERCOUNTER #9 (8) 1.02 * #12 -' /2 "C 1P -20A 9 10 1P -20A #12 -'/2'C 3 /; #8 - 'C 1.20 22 LIGHTING (1) FOOD WARMER #9,1 (8) 1.40 #12 -'/2'C 1P -20A 11 12 1P -20A #12 -1/2" C 1.20 LIGHTING (1) BACK BAR COOLER #/45 (8) 1.06 #12 - WC #12 -' /2 "C 1P -20A 13 14 1P -20A #12 - Y2 "C 0.90 26 LIGHTING (1) WAREWASHER #15 (8) , 1.92 #12 -'/2'C 1P -20A 15 16 1P -20A #12-1/2'C 0.80 LIGHTING (1) DISPLAY CASE #t32 (8) 1.44 30 #12 -' /i'C 1 P -20A 17 18 1 P -20A X12 - Y2'C 1.80 • LIGHTING (1) BACK BAR COOLER #44 (8) 1.06 X12 -1/2'C 1 P -20A 19 20 1 P -20A #12 - Y2'C 1.20 LIGHTING (1) UNDERBAR BLENDER #34 (8) 1.80 #r!12 - Y2'C 1P -20A 21 22 1P -20A #12- Y2'C 1,20 #12 - % "C SIGN LIGHTING (3) ATM MACHINE (11) 1.00 #12 -'/2'C 1P -20A 23 24 1P -20A #12 -'/2'C 1.20 SIGN LIGHTING (3) RECEPTACLES (9) 0.80 X12 -1 /2"C 1 P -20A 25 26 1 P -20A X12 -1/2"C 0.20 40 IN DUCT SMOKE DETECTOR (11) RECEPTACLES (9) 0.80 #12 -' /2rC 1P -20A 27 28 1P -20A #12 -'/2'C 1 #12 - 3/. "C 1.00 LIGHTING (1) COMPUTER EQUIP (10) 1.00 PHASE C = 190.80 AMPS #I'•12 -1/2"C 1P -20A 29 30 1P -20A #12 -1/2" C 1,00 LIGHTING (1) TELEPHONE BOARD (11) 0.50 #12 -1/2"C 1P -20A 31 1 32 1P -20A #12 -1/2" C 1.20 SIGN LIGHTING (3) SPARE - 1P -20A 33 34 1P -20A #12 -1/2" C 1.20 SIGN LIGHTING (3) RECEPTACLES (9) 1 1.20 #12 -' / "C 1P -20A 35 36 1P -20A #12 -1/2'C 1.20 SIGN LIGHTING (3) RECEPTACLES (9) 1.00 #12 - Y2C 1P -20A 37 38 1P -20A #12 -1/2" C 1.20 SIGN LIGHTING (3) RECEPTACLES (9) n 0.80 #12 -'/2'C 1P -20A 39 40 1P -20A #12 - Y2'C 1.20 SIGN LIGHTING (3) RECEPTACLES (9) 0.80 #12 -' / "C 1P -20A 41 42 1P -20A - SPARE CONNECTED KVA LOAD 11.07 5.48 11.20 11.45 CONNECTED KVA LOAD PHASE A = 22.27 KVA PHASE B = 20.93 KVA TOTAL = 43.20 KVA LOADS: CONN KVA DEMAND NEC KVA NOTES, 1. LIGHTING 14.05 125% 17.56 A. LARGEST MOTOR AT 125% 2. TRACK LIGHTING 0.00 125% 0.00 B. FIRST 10KVA AT 100% + REMAINDER OVER 10KVA AT 50% 3. SIGN LIGHTING 8.40 125% 10.50 4. SHOW WINDOWS 0.00 125'✓% 0.00 5. HEATING 0.00 100% 0.00 6. AIR CONDITIONING 0.00 (A) 0.00 7, MOTORS 0,00 (A) 0.00 8. KITCHEN EQUIPMENT (OVER 6) 12.65 65% 8.22 9. RECEPTACLES 5.40 (B) 5.40 10. MISC. CONTINUOUS 1.00 125% 1.25 11. MISC. NON - CONTINUOS 1.70 100% 1.70 SUBTOTAL: 43.20 44.64 LESS SMALLEST AC /HEAT: 0.00 TOTAL DEMAND: 44.64 KVA / 240 VAC = 185.98 AMPS MANUFACTURER: SIEMENS VO LTAG E: 120/240 VAC 30 4W TYPE: LOADCENTER BUS RATING: 400 A MOUNTING: FLUSH PANEL 'A' MAIN: M.L.O. BREAKERS:10KAIC NEUTRAL: FULL IDENTIFICATION A *B C WIRE TRIP CKTCKT TRIP WIRE A *B C IDENTIFICATION 44.0 #6 - 1 "C 1 2 #4 -1 "C 60.6 AC -RTU • 44.0 3P -50A 3P -70A #4- 60.6 AC -RTU #6 - 1"C 3 4 44.0 • 60.6 11.0 #6 -1 "C 6 6 #4 - 1 "C 11.0 #12-%"C 7 8 #12 - %-'C HOOD FAN 3P -20A 3P -20A r HOOD FAN #12 - 31. "C 9 10 11.0 #12 - % "C 11.0 15.0 • SPACE #12 - WC 11 13 12 14 #12 - WC SPACE 10.8 ICE MAKER #18 10.8 3P -20A 3P -20A #12 - 3/, "C • 15.0 COOLER EQUIPMENT #12 - Y4 "C 15 16 17 18 #12 -% "C 10.8 25.0 #12 -WC + 15.0 2.5 #8 - WIC 19 20 #12 - % "C GRIDDLE #7 2P -35A 2P -20A SITE LIGHTING 3 /; #8 - 'C 21 22 25.0 #12 - 3 /,,C 2.5 23 24 MICROWAVE #11 • 13.8 • 25.0 #12 - WC 2P -20A It 13.2 SPACE 21 26 #8 - 3/;'C 27 29 #12 - WC GRIDDLE #7 2P -35A 2P -20A WATER FEATURE PUMP 26 30 #12 -'/ "C 25.0 #8 - 3 /;'C N 13.2 8,4 #12 - Y4 "C 31 32 ESPRESSO #47 2P -20A #12 - % "C 33 34 • 8.4 • • 35 37 36 38 8.4 ESPRESSO #47 #12 -' ✓;'c 1 2P -20A 35 40 41 42 8.4 1 #12 - 3/. "C CONNECTED AMP LOAD 113.0 132.6 1 102.01 85.1 102.3 I8.8 CONNECTED AMID LOAD "DO NOT CONNECT ANY 120V PHASE A = 202.10 AMPS CIRCUITS TO PHASE B (HI -LEG) PHASE B = 234.'90 AMPS PHASE C = 190.80 AMPS t1 N 2 r a. 0 •I ■ DdLewi:Architecturo +Design AR0017357 ID0004536 wwwAbla1.us 120 NE 27 ST. # 500 /MIAMI, FL 33137 T 305.572.1220 / Fx 305.572.9161 ej � 5.J u x. Ln, TER,TR.IANA, P.E. Florida Registration N• "PE065707 SEAL / SIGNATURE ar �. EsPREc. SVMI CAFE PROJECT # 0804 5800 SW 73 RD ST SOUTH MIAMI, FL 33143 LESSEE; W ILL Y QUINTANA 301 COLLINS AVE, SUITE 2707 MAIMI BEACH, FL 33141 F.305.867.7073 STRUCTURAL ENGINEER: IN - RAMIREZ, 2000 N.W. 85 PL. SUITE 102 MAIMI, FL ftain@tain-ramirez.com MECH, ELEC, PLUMB, FIRE PROTECT, ENO: LTRIANA & ASSOCIATES, INC CONSULTING ENGINEERS C.A.# 26644 9701 S.W. 56th St, MIAMI,,-FL 33165 CIVIL ENGINEER: LANDSCAPE ARCHITECT: ILLUSION LANDSCAPE & DESIGN MIAMI, FL LESSOR: ROGER D. SHAY& W. GRACE D 13635 DEERING BAY RD, PH 253 CORAL GABLES, FL 33158 -2812 REVISIONS *' " DATE Zi10.15.09 OWNER'S s REQUESTED VE ISSUE DATE JULY /31/2008 DWN APPRV DBL Dr2win : PANELS, RISERS Scale : 1/4" @24X36 Phase: CONSTRUCTION DOCUMENTS Sheet Number: E -5