05-41(2)-015SPLIT SYSTEM SCHEDULE
UNIT DESIGNATION
AC -1
AC -2
AREA SERVED
LIVING AREAS
BEDROOMS
MANUFACTURER
RUUD
RUUD
FAN COIL UNIT MODEL No.
UBHK244J11SFC
UBHK21J11SFB
CONDENSING UNIT MODEL No.
UAPB042JAZ
UAP8030JAZ
MINIMUM SEER
14.8
14.7
TOTAL CAPACITY BTUH
40000
29400
SENSIBLE CAPACITY BTUH
30000
22400
COIL ENTERING CONDITIONS
80/67 DEG DB /WB
80/67 DEG DB /WB
AMBIENT AIR TEMPERATURE
95 DEG DB
95 DEG DB
CFM SUPPLY
1400
1000
EXTERNAL STATIC PRESSURE
0.40
0.30
FAN COIL UNIT FAN HP
1/2
1/2
HEATER KW
9.6
9.6
CONDENSING UNIT FLA
18
14
VOLTAGE FOR SYSTEM
240 -1 -60
240 -1 -60
FAN COIL UNIT WEGHT LBS
125
109
CONDENSING UNIT WEIGHT LBS
255
220
FAN COIL UNIT LOCATION
AC RM
AC RM
CONDENSING UNIT LOCATION
GRADE
GRADE
REFRIGERANT LINES SIZES
SUCTION
1 -1/8"
3/4"
LIQUID
3/8
5/16
NOTES:
1- FURNISH ROOM THERMOSTAT,
LOW VOLTAGE
1- STEP COOL, 1 -STEP HEAT WITH
FAN -AUTO SWITCH
AND COOL -OFF -HEAT SWITCH.
GENERAL NOTES-HVAC
01- all work shall conform to the latest edition of the florida building code
and applicable state and local ordinances.
02- contractor shall warrant all work to be free of defects in workmanship
and materials for a period of one year after acceptance of project.
03- provide all the necessary instructions to the owner, including all required
printed materials, in the operation of the machanical systems.
04- provide equipment maintenance and instruction manuals,etc. to the owner
submit architect /engineer for approval.
05- submit equipment, accesories, controls, ductwork, etc. shop drawings
before proceeding with the purchase or installation of same.
06- provide all the necessary access panels to valves, fire dampers, etc
as may be required.
07- balance all air systems to within 10% of quantities shown on plans.
08- all work must be coordinated with all other trades prior to execution
of same.
09- a/c contractor must obtain his own permit and pay for all required fees.
10- conditioned ductwork shall be as follow:
class I fiberboard, coated internally, R -6 value to SMACNA'S
fiberglass duct manual.
and applicable state and local ordinances.
11- ventilation ductwork shall be gals. sheetmetal per SMACNA'S LOW
PRESSURE METAL DUCT STANDARDS. vent ductwork shall not be insulated.
12- all duct dimensions shown on plans are clear inside dimensions.
13- refrigerant piping shall be copper type L or K or ACR copper tubing with
wrought copper fittings. joints shall be soldered with 95/5 solder
and suittable flux.
14- insulate suction lines with 3/4" foamed plastic or closed cell polyethylene
pre - molded pipe insulation.
15- provide accesory low volt room thermostats with fan - off -auto and
cool- off -heat switches and heating subbase.
16- carefully coordinate location of ductwork with all structural elements
providing duct sleeves as required.
17- control wiring shall be the responsibility of the machanical contractor.
cool- off -heat switches and heating subbase.
HVAC CHECKLIST
HVAC DESIGN REQUIRES
DUCT SMOKE DETECTORS
NO
FIRE DAMPERS
NO
SMOKE DAMPERS -
RPM
FIRE RATED ENCLOSURE
NO
FIRE -RATED FLOOR /
NO
CEILING ASSEMBLY
NO
FIRE STOPPING-
NO
SMOKE- CONTROL
NO
FAN SCHEDULE
MARK
TYPE
CFM
ESP
IWG
RPM
DRIVE
WATTS
VOLTAGE
MANUFACTURER
MODEL
CONTROL
AREA SERVED
EF -A
CEILING
50
1/8
1700
DIRECT
50
120 -1 -60
PENN
Z1
LIGHT - SWITCH
TOILETS
NOTE : FANS WITH INTEGRAL BACKDRAFT DAMPER.
3/4" DEEP x 1/8"
POWERFn Ar-n iATFn
PINS.-
29EX
DEEP
SPECIAL MECHANICAL NOTES
1- ALL EXHAUST DUCT SHALL BE CONSTRUCTED OF SHEETMETAL
TERMINATE OUTSIDE THE BUILDING AND BE EQUIPPED WITH
BACKDRAFT DAMPERS (NO T -FIN ALLOWED)
2- DUCTS FROM TOILETS ROOMS SHALL DISCHARGE TO THE
OUTSIDE OF THE BUILDING, SHALL TERMINATE NO LESS
THAN 6 INCHES ABOVE THE FINISHED ROOF SURFACE, AND
SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL
OF MESH SIZE NO LARGER THAN 1/2 INCH. PROVIDE GOOSENECK
OR RAIN CAP ON ROOF TERMINATION
3- CLOTHES DRYER EXHAUST DUCTS SHALL NOT BE SCREENED
4- CLOTHES DRYERS EXHAUST DUCTS OR VENTS SHALL COMPLY
WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS, BE
CONSTRUCTED OF MINIMUM 30gage GALV. METAL PIPE
HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING
IN THE DIRECTION OF AIR FLOW. DUCT JOINTS SHALL NOT
BE ASSEMBLED WITH SHEETMETAL SCREWS OR OTHER
FASTENERS WHICH EXTEND INTO THE DUCT WALLS
3/4" DEEP x 1/8"
DOWERED ACTUATED,
'INS.
1 " WIDE x22GA
STRAP ® 8 " -0 0/C
PINS.
,i VT x 28 GA
n v
G.M. STRIP AT
SUPPORT.
DUCT SUPPORT DETAILS
NTS
FINISHED
ATTIC
SPACE
EXHAUST DUCTS
26 MSG GALV. SHEETMETAL-
DRYER DUCTS WITH SMOOTH
INTERIOR SURFACES.
D❑ NOT USE SCREWS OR OTHER
FASTENERS EXTENDING INTO
CEILING
VENT CAP WITH MAX. 1/2' '
MESH SIZE SCREEN- EXCEPT
DRYER VENTS SHALL NOT BE
SCREENED
,FLASHING AND ROOFING SEAL
BY GENERAL CONTRACTOR
TILED
ROOF DECK
F
DUCT COLLAR "`L
ATTACHED TO DECK
WITH HILTI REDHEADS
OR 1/4' CREWS
DUCT TO UNIT
ROOF VENT DETAIL
N.T.S.
RIGID DUCT UP
TO 29" WIDTH
OR 16" DEEP.
,.I V L x 28 GA
G.M. STRIP AT
SUPPORT.
NOTE 1
4 " CLEAR ALL ARC
FLOAT SWI
TO SHUT Fc
IN CASE C
oVEI�Lou
C PER FBC
CONDENSING
UNIT
CONCRETE BASE
W/bxb -10/10 W WF
COND. UNIT TO BE
SECURED TO CONC. SLAB
W/ (1) 3/161X3" TAPCONS
PER STRAP a EA. END (TYPICAL)
TO WITHSTAND 146 MPA WINDS
POWER 4 CONTROL
CONNECTIONS
- LIQUID LINE W/O
INSULATION
-4 1/0 SCH 40
P.VL. PIPE
(MAX ANGLE 45 DEGRE)
LINES
CONDENSING UNIT MOUNTING DETAIL
NTS
<. DUCTS
r INSULATION
CTRIC STRIP
►TER
.TORY FABRICATED
ER SECTION
4'--,g9= SUPPORTS
45 DECs. ELBOWS - TYPICAL
. LINES IN
'VC CONDUIT
EFZGROUND
A/C EQUIPMENT CLOSET DETAIL
NTS
i
1�
M
0
Ok
G
0
N
to 1E
r" ..
r
'p' r
Y-�
r v y
v �:
rn
O rn
(A zn
O
O >
Z .�
�v�
7o r»
r" (A
O v
3v�
~irnz
r n
SHEET
AC- 2
•.
,; _
C
1�
M
0
Ok
G
0
N
to 1E
r" ..
r
'p' r
Y-�
r v y
v �:
rn
O rn
(A zn
O
O >
Z .�
�v�
7o r»
r" (A
O v
3v�
~irnz
r n
SHEET
AC- 2