Loading...
05-41(2)-015SPLIT SYSTEM SCHEDULE UNIT DESIGNATION AC -1 AC -2 AREA SERVED LIVING AREAS BEDROOMS MANUFACTURER RUUD RUUD FAN COIL UNIT MODEL No. UBHK244J11SFC UBHK21J11SFB CONDENSING UNIT MODEL No. UAPB042JAZ UAP8030JAZ MINIMUM SEER 14.8 14.7 TOTAL CAPACITY BTUH 40000 29400 SENSIBLE CAPACITY BTUH 30000 22400 COIL ENTERING CONDITIONS 80/67 DEG DB /WB 80/67 DEG DB /WB AMBIENT AIR TEMPERATURE 95 DEG DB 95 DEG DB CFM SUPPLY 1400 1000 EXTERNAL STATIC PRESSURE 0.40 0.30 FAN COIL UNIT FAN HP 1/2 1/2 HEATER KW 9.6 9.6 CONDENSING UNIT FLA 18 14 VOLTAGE FOR SYSTEM 240 -1 -60 240 -1 -60 FAN COIL UNIT WEGHT LBS 125 109 CONDENSING UNIT WEIGHT LBS 255 220 FAN COIL UNIT LOCATION AC RM AC RM CONDENSING UNIT LOCATION GRADE GRADE REFRIGERANT LINES SIZES SUCTION 1 -1/8" 3/4" LIQUID 3/8 5/16 NOTES: 1- FURNISH ROOM THERMOSTAT, LOW VOLTAGE 1- STEP COOL, 1 -STEP HEAT WITH FAN -AUTO SWITCH AND COOL -OFF -HEAT SWITCH. GENERAL NOTES-HVAC 01- all work shall conform to the latest edition of the florida building code and applicable state and local ordinances. 02- contractor shall warrant all work to be free of defects in workmanship and materials for a period of one year after acceptance of project. 03- provide all the necessary instructions to the owner, including all required printed materials, in the operation of the machanical systems. 04- provide equipment maintenance and instruction manuals,etc. to the owner submit architect /engineer for approval. 05- submit equipment, accesories, controls, ductwork, etc. shop drawings before proceeding with the purchase or installation of same. 06- provide all the necessary access panels to valves, fire dampers, etc as may be required. 07- balance all air systems to within 10% of quantities shown on plans. 08- all work must be coordinated with all other trades prior to execution of same. 09- a/c contractor must obtain his own permit and pay for all required fees. 10- conditioned ductwork shall be as follow: class I fiberboard, coated internally, R -6 value to SMACNA'S fiberglass duct manual. and applicable state and local ordinances. 11- ventilation ductwork shall be gals. sheetmetal per SMACNA'S LOW PRESSURE METAL DUCT STANDARDS. vent ductwork shall not be insulated. 12- all duct dimensions shown on plans are clear inside dimensions. 13- refrigerant piping shall be copper type L or K or ACR copper tubing with wrought copper fittings. joints shall be soldered with 95/5 solder and suittable flux. 14- insulate suction lines with 3/4" foamed plastic or closed cell polyethylene pre - molded pipe insulation. 15- provide accesory low volt room thermostats with fan - off -auto and cool- off -heat switches and heating subbase. 16- carefully coordinate location of ductwork with all structural elements providing duct sleeves as required. 17- control wiring shall be the responsibility of the machanical contractor. cool- off -heat switches and heating subbase. HVAC CHECKLIST HVAC DESIGN REQUIRES DUCT SMOKE DETECTORS NO FIRE DAMPERS NO SMOKE DAMPERS - RPM FIRE RATED ENCLOSURE NO FIRE -RATED FLOOR / NO CEILING ASSEMBLY NO FIRE STOPPING- NO SMOKE- CONTROL NO FAN SCHEDULE MARK TYPE CFM ESP IWG RPM DRIVE WATTS VOLTAGE MANUFACTURER MODEL CONTROL AREA SERVED EF -A CEILING 50 1/8 1700 DIRECT 50 120 -1 -60 PENN Z1 LIGHT - SWITCH TOILETS NOTE : FANS WITH INTEGRAL BACKDRAFT DAMPER. 3/4" DEEP x 1/8" POWERFn Ar-n iATFn PINS.- 29EX DEEP SPECIAL MECHANICAL NOTES 1- ALL EXHAUST DUCT SHALL BE CONSTRUCTED OF SHEETMETAL TERMINATE OUTSIDE THE BUILDING AND BE EQUIPPED WITH BACKDRAFT DAMPERS (NO T -FIN ALLOWED) 2- DUCTS FROM TOILETS ROOMS SHALL DISCHARGE TO THE OUTSIDE OF THE BUILDING, SHALL TERMINATE NO LESS THAN 6 INCHES ABOVE THE FINISHED ROOF SURFACE, AND SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL OF MESH SIZE NO LARGER THAN 1/2 INCH. PROVIDE GOOSENECK OR RAIN CAP ON ROOF TERMINATION 3- CLOTHES DRYER EXHAUST DUCTS SHALL NOT BE SCREENED 4- CLOTHES DRYERS EXHAUST DUCTS OR VENTS SHALL COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF MINIMUM 30gage GALV. METAL PIPE HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE DIRECTION OF AIR FLOW. DUCT JOINTS SHALL NOT BE ASSEMBLED WITH SHEETMETAL SCREWS OR OTHER FASTENERS WHICH EXTEND INTO THE DUCT WALLS 3/4" DEEP x 1/8" DOWERED ACTUATED, 'INS. 1 " WIDE x22GA STRAP ® 8 " -0 0/C PINS. ,i VT x 28 GA n v G.M. STRIP AT SUPPORT. DUCT SUPPORT DETAILS NTS FINISHED ATTIC SPACE EXHAUST DUCTS 26 MSG GALV. SHEETMETAL- DRYER DUCTS WITH SMOOTH INTERIOR SURFACES. D❑ NOT USE SCREWS OR OTHER FASTENERS EXTENDING INTO CEILING VENT CAP WITH MAX. 1/2' ' MESH SIZE SCREEN- EXCEPT DRYER VENTS SHALL NOT BE SCREENED ,FLASHING AND ROOFING SEAL BY GENERAL CONTRACTOR TILED ROOF DECK F DUCT COLLAR "`L ATTACHED TO DECK WITH HILTI REDHEADS OR 1/4' CREWS DUCT TO UNIT ROOF VENT DETAIL N.T.S. RIGID DUCT UP TO 29" WIDTH OR 16" DEEP. ,.I V L x 28 GA G.M. STRIP AT SUPPORT. NOTE 1 4 " CLEAR ALL ARC FLOAT SWI TO SHUT Fc IN CASE C oVEI�Lou C PER FBC CONDENSING UNIT CONCRETE BASE W/bxb -10/10 W WF COND. UNIT TO BE SECURED TO CONC. SLAB W/ (1) 3/161X3" TAPCONS PER STRAP a EA. END (TYPICAL) TO WITHSTAND 146 MPA WINDS POWER 4 CONTROL CONNECTIONS - LIQUID LINE W/O INSULATION -4 1/0 SCH 40 P.VL. PIPE (MAX ANGLE 45 DEGRE) LINES CONDENSING UNIT MOUNTING DETAIL NTS <. DUCTS r INSULATION CTRIC STRIP ►TER .TORY FABRICATED ER SECTION 4'--,g9= SUPPORTS 45 DECs. ELBOWS - TYPICAL . LINES IN 'VC CONDUIT EFZGROUND A/C EQUIPMENT CLOSET DETAIL NTS i 1� M 0 Ok G 0 N to 1E r" .. r 'p' r Y-� r v y v �: rn O rn (A zn O O > Z .� �v� 7o r» r" (A O v 3v� ~irnz r n SHEET AC- 2 •. ,; _ C 1� M 0 Ok G 0 N to 1E r" .. r 'p' r Y-� r v y v �: rn O rn (A zn O O > Z .� �v� 7o r» r" (A O v 3v� ~irnz r n SHEET AC- 2