Loading...
05-1332-009AIR DEFLECTOR EXTRACTOR TRUNK DUCT AIR FLOW � _ I AIR 0 SPACER REQUIRED ON INSULATED DUCTS SET SCREW CLINCH EDGES GALV. STEEL ROD BRANCH DUCT 0 1J TYPICAL DETAIL OF�A 90" DUCT TAP WITH AIR DEFLECTOR D S= D/6 (MIN.2 ") W /5= NO. OF SPACES R= 1 1/4 5 L= 3/4 5 n.t.s. BLADES IN TRANSITION ELC50WS SHALL BE DETERMINED ACCORDING TO SMALLEST WIDTH OF ELBOW. SINGLE VANE H. INSULATED SUPPLY DUCT AS PER PLAN R 18 GA SMALL 51 38 24 LARGE 114 83 22 BOLT, SCREW OR WELD TO DUCT SCREW EVERT SIXTH VANE �� M, A mIi' L RECTANGULAR DUCT ELBOW DETAIL n.t.s. FLOOR/ CEILING STRUCTURE FLEX DUCT MIN .145 DIA. POWER DRIVEN PINS, OR 3/16x1 --34" T.CONS AT CONC,, OR J80-1/2' WOOD SCREW AT WOOD(TYP) FIBERGLASS DUCT AS PER PLAN MIN 26 GA. 1 -1/2" WIDE FLAT MTL STRAP HANGERS SECURED TO STRUCTURE MIN 12 GA WIRE HANGER (OR MIN 1 " -22 GA STRAP) W/ 22 GA CHANNEL SUPPORTS FOR DUCT 18" W & SMALLER, OR 18 GA CHANNEL SUPPORT FOR DUCT MORE THAN 18" W. DUCT SUPPORT HANGER DETAIL GALV MTL W.P. ROOF CAP. GALV MTL SCREEN CLOSURE OVER ROOF CAP OPENING. OMIT SCREEN FOR DRYER VENT CAPS SECURE ROOF CAP AS PER MANUF. SPEC'S i DAMPER FLASHING BY ROOFING CONTRACTOR 0 i HVAC SYMBOLS GENERAL ROOF TRUSS I 4" DIA. DUCT ROUTED UP THRU CEILING SPACE NOTE: ROOF CAP MANUFACTURER TO BE "NUTONE" OR APPROVED EQUAL. ROOF CAP DETAIL n.t.s. A//C EQUIPMENT SCHEDULE INSULATED SUPPLY DUCT AS PER PLAN �. �. �........ INSULATED RETURN DUCT AS PER PLAN ! DIRECTION OF AIR FLOW EXIST TO REMAIN INSULATED FLEXIBLE DUCT AS PER PLAN 7 SUPPLY AIR DIFFUSER 01 RETURN AIR DIFFUSER 100 EXHAUST FAN AA PER PLAN � MANUAL DAMPER ROOF TRUSS I 4" DIA. DUCT ROUTED UP THRU CEILING SPACE NOTE: ROOF CAP MANUFACTURER TO BE "NUTONE" OR APPROVED EQUAL. ROOF CAP DETAIL n.t.s. A//C EQUIPMENT SCHEDULE UNIT DESIGNATION AHU -1 CU -1 AREA SERVED BATHROOM AREA SERVED EXIST TO REMAIN TYPE CENTRIFUGAL FAN RPM TOTAL COOLING CAPACITY, MBH 33.6 100 STATIC PRESS. 0.125 SENSIBLE COOLING CAPACITY, MBH LZ. 5 H.P. MOTOR 60 WATTS 0f J AIR SUPPLY (CFM) 1200 LOREN COOK CO. MODEL NO. LITTLE GEMINI II OUTSIDE AIR, CFM MINIMUM N/A V VVVV a°z = No. OF MOTORS — HP NON — OVERLOAD 1— 1/4 ELECTRIC HEATER KW STAGES 10 -1 • • Q ELECTRICAL SERVICE AVAILABLE 240 -1 -60 • • • • Y • y F.L. AMPS 2.0 V Y of No. OF MOTORS -- HP 1 — 1/8 • V Y V V • cf) F.L. AMPS 19.3 V V V V V w o MINIMUM CIRCUIT AMP /MAXIMUM FUSE 45/45 U UVY V 4VV o SEER 10.0 s 4 u V•• 0 REFRIGERANT LINES SUCTION IN - LIQUID IN 7/8" - 3/8" DESIGN MANUFACTURER TRANE XE 1200(EXIST) AIR HANDLER MODEL NO. TWE036C140FO(EXIST) CONDENSING UNIT MODEL NO. TTP036T10OA2(EXIST) NOTES ACCESSORIES 1� PROVIDE FACTORY FURNISHED ELECTRIC HEATER WITH SINGLE POINT CONNECTION. NOTE: UNIT TO BE INSTALLED ABOVE FLOOD ELEVATION BOLT CONDENSING UNIT TO SUPPORTS TO WITHSTAND 140 MPH HURRICANE FORCE WINDS CONDEN5 UNIT INSTALL (2) MIN 1 /8"0 STAINLESS STEEL GABLES. ATTACHED TO MIN 1/2 "0 5T. ASTL. A.B. W/ CLOSED EYE BOLT. CABLE TO BE INSTALLED TIGs 4T AND LOOPED THRU EYE BOLT AND CRIMPED AT BOTH ENDS. MIN 3/32" TH. 2 "x2 "xl" WIDE GLIF5 AT EA CORNER. SECURE W/ (2"12 TEK SCREWS AT UNIT < (2)1/4 "xl -3/4" TAPCON TO CONC SLAB. 4" TH CONC BASE W 6" MIN. 6 X 6 - 10/10 WWF SCH. 40 PVC CONDUIT W/ SOLVENT WELDED JOINTS RUN UNDER SLAB. USE 4" OR 6" DIA. AS REQ. POWER i CONTROL CONNECTIONS n 6" MIN. Oi-- 4" MIN. LIQUID t SUCTION LINE W/ INSULATION SEAL W/ U.L. LABEL SILICONE SEALANT COND. UNIT FASTENING DETAIL./ REFRIGERANT PIPING N.T.S. LOUVERED DIFFUSER LOW VELOCITY AIR FLOW SUPPLY AIR DUCT (SEE PUN VIEW) SEAL JOINT WITH DUCT SEALER AND TAPE. INSULATED FLEX DUCT (8' -0" MAX.) THERMOFIN OR EQUAL --- SEAL JOINT WITH DUCT SEALER AND TAPE. FLEXIBLE DUCT CONNECTION DETAIL n.t.s. FAN SCHEDULE FAN NO. ALL BATH EXHAUST FANS AREA SERVED BATHROOM LOCATION CEILING TYPE CENTRIFUGAL FAN RPM 1200 C F M 100 STATIC PRESS. 0.125 TYPE DRIVE DIRECT H.P. MOTOR 60 WATTS ELECT. CHARACT. 120/1/60 MANUFACTURER LOREN COOK CO. MODEL NO. LITTLE GEMINI II REMARKS A,B A) BACKDRAFT DAMPER B) ROUTE 4 "0 EXHAUST DUCT AS PER PLAN HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR .. 00 LL -- CONN. TO INSULATION W/ FIRE DAMPERS V SMOKE DAMPERS � VI ,i FIRE RATED ENCLOSURE • V V FIRE RATED ROOF /FLOOR CEILING ASSEMBLY " V V FIRE STOPPING V Y • SMOKE CONTROL • y y u V V iY•y W V ` y y • y ` AIR O V�v • GENERAL NOTES. 1.— THIS JOB REQUIRES A VERY THOROUGH COORDINATION BETWEEN ALL TRADES AND THE CONTRACTOR SHALL COORDINATE THE INSTALLATIONS OF THE DIFFERENT TRADES AND NOTIFY THE ARCHITECT IF ANY CONFLICTS OCCUR BEFORE INSTALLATIONS BEGIN. 2.— THE CONTRACTOR SHALL NOT FABRICATE ANY DUCTWORK PRIOR TO VERIFICATION OF ROUTING, SIZES AND AVAILABLE SPACE. 3•— CONTRACTOR SHALL FURNISH WRITTEN GUARANTEE THAT ALL WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. 4.— ALL WORK SHALL BE IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING CODE AND ALL LOCAL CODES HAVING JURISDICTION; NFPA 90 A do B, ASHRAE GUIDE AND SMACNAS DUCT CONSTRUCTION STANDARDS. 5.— ALL SUPPLY do RETURN GALVANIZED STEEL DUCTWORK TO BE CONSTRUCTED IN ACCORDANCE WITH SMACNA'S STANDARDS FOR LOW PRESSURE DUCTS. ALL JOINTS AND SEAMS OF INTERIOR DUCTS TO BE SEALED WITH 4" TAPE (PERMACELL #691AF) APPLIED WITH ADHESIVE TO MAKE JOINTS AIRTIGHT. 6.— N/A 7.— ALL FLEXIBLE DUCT RUNOUTS SHALL BE FLEXIBLE INSULATED DUCTWORK REINFORCED WITH A WIRE HELIX, PERMANENTLY BONDED WITHIN FABRIC, INSULATED, AND WITH A VAPOR BARRIER OF ALUMINUM METALIZED POLYESTER FILM LAMINATED TO GLASS MESH. WIREMOLD COMPANY OR APPROVED EQUAL. 8.— AIR DISTRIBUTION DEVICES ALL ALUMINUM CONSTRUCTION WITH OPPOSED BLADE DAMPERS AND EQUALIZING GRID. BARBER COLMAN, TITUS, CARNES, TUTTLE AND BAYLEY. 9.— FIRE DAMPERS SHALL BE PROVIDED AS CALLED FOR ON PLANS. FIRE DAMPERS SHALL BE AIR BALANCE 119 ---UL CONSTRUCTED AND INSTALLED TO CONFORM WITH NFPA -90A AND U.L. REQUERIMENTS. 10.— EXHAUST FANS — CAPACITIES AS CALLED FOR ON SCHEDULE. ALUMINUM CONSTRUC- TION, DIRECT DRIVE, BACK DRAFT DAMPER. ALUMINUM BIRD SCREEN, SAFETY SWITCH. 11.— ALL REFRIGERATION PIPING TO BE COPPER TYPE "K" HARD DRAWN WITH SWEAT AND WROUGHT COPPER FITTINGS. 12.— SUCTION REFRIGERATION LINES SHALL BE INSULATED WITH 3/4" ARMAFLEX. 13.— PROVIDE ALL NECESSARY CONTROLS FOR THE OPERATION OF THE A/C SYSTEM. 14.— VOLTAGES SHOULD BE VERIFY PRIOR TO ANY INSTALLATION. 15.— TEST do BALANCE TO BE PERFORMED BY AN INDEPENDENT TEST AND BALANCE AGENCY. ADJUST DAMPERS AND FANS TO OBTAIN AIR QUANTITIES WITHIN 5% OF THOSE INDICATED ON THESE DRAWINGS. OBTAIN FULL LOAD AMPS READINGS FOR ALL MOTORS AT BALANCED CONDITIONS. RECORD OUTDOOR AND INDOOR DRY AND WET BULB TEMPERATURES AT BALANCED. SUBMIT ALL TEST AND BALANCE REPORTS TO OWNER FOR APPROVAL. FLOOR/ CEILING STRUCTURE MIN 26 GA. FLAT MTL STRAP HANGERS SECURED TO STRUCTURE END VIEW REFRIGERANT LIQUID LINE. CONN. TO INSULATION W/ PLASTIC STRAP. REFRIGERANT SUCTION LINE CONTINUOUS INSULATION o REFRIGERANT LIQUID LINE. FLOOR/ CEILING .. 00 LL -- CONN. TO INSULATION W/ STRUCTURE ��__� PLASTIC STRAP. MIN 26 GA. FLAT � VI REFRIGERANT SUCTION LINE V•• y • V V 4 � V " V " yV••V • V Y • • y y • V VYUUy V V VVVV • V• VV• Y • • V 6V • V V • • • • Y • y • Y • V V Y V V V • V V • V Y V V • y V • u • V V V V V • • • V V • •• U UVY V 4VV • i ...... s 4 u V•• V V Y •• U• u V V iY•y W V ` y y • y ` AIR O V�v • GENERAL NOTES. 1.— THIS JOB REQUIRES A VERY THOROUGH COORDINATION BETWEEN ALL TRADES AND THE CONTRACTOR SHALL COORDINATE THE INSTALLATIONS OF THE DIFFERENT TRADES AND NOTIFY THE ARCHITECT IF ANY CONFLICTS OCCUR BEFORE INSTALLATIONS BEGIN. 2.— THE CONTRACTOR SHALL NOT FABRICATE ANY DUCTWORK PRIOR TO VERIFICATION OF ROUTING, SIZES AND AVAILABLE SPACE. 3•— CONTRACTOR SHALL FURNISH WRITTEN GUARANTEE THAT ALL WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. 4.— ALL WORK SHALL BE IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING CODE AND ALL LOCAL CODES HAVING JURISDICTION; NFPA 90 A do B, ASHRAE GUIDE AND SMACNAS DUCT CONSTRUCTION STANDARDS. 5.— ALL SUPPLY do RETURN GALVANIZED STEEL DUCTWORK TO BE CONSTRUCTED IN ACCORDANCE WITH SMACNA'S STANDARDS FOR LOW PRESSURE DUCTS. ALL JOINTS AND SEAMS OF INTERIOR DUCTS TO BE SEALED WITH 4" TAPE (PERMACELL #691AF) APPLIED WITH ADHESIVE TO MAKE JOINTS AIRTIGHT. 6.— N/A 7.— ALL FLEXIBLE DUCT RUNOUTS SHALL BE FLEXIBLE INSULATED DUCTWORK REINFORCED WITH A WIRE HELIX, PERMANENTLY BONDED WITHIN FABRIC, INSULATED, AND WITH A VAPOR BARRIER OF ALUMINUM METALIZED POLYESTER FILM LAMINATED TO GLASS MESH. WIREMOLD COMPANY OR APPROVED EQUAL. 8.— AIR DISTRIBUTION DEVICES ALL ALUMINUM CONSTRUCTION WITH OPPOSED BLADE DAMPERS AND EQUALIZING GRID. BARBER COLMAN, TITUS, CARNES, TUTTLE AND BAYLEY. 9.— FIRE DAMPERS SHALL BE PROVIDED AS CALLED FOR ON PLANS. FIRE DAMPERS SHALL BE AIR BALANCE 119 ---UL CONSTRUCTED AND INSTALLED TO CONFORM WITH NFPA -90A AND U.L. REQUERIMENTS. 10.— EXHAUST FANS — CAPACITIES AS CALLED FOR ON SCHEDULE. ALUMINUM CONSTRUC- TION, DIRECT DRIVE, BACK DRAFT DAMPER. ALUMINUM BIRD SCREEN, SAFETY SWITCH. 11.— ALL REFRIGERATION PIPING TO BE COPPER TYPE "K" HARD DRAWN WITH SWEAT AND WROUGHT COPPER FITTINGS. 12.— SUCTION REFRIGERATION LINES SHALL BE INSULATED WITH 3/4" ARMAFLEX. 13.— PROVIDE ALL NECESSARY CONTROLS FOR THE OPERATION OF THE A/C SYSTEM. 14.— VOLTAGES SHOULD BE VERIFY PRIOR TO ANY INSTALLATION. 15.— TEST do BALANCE TO BE PERFORMED BY AN INDEPENDENT TEST AND BALANCE AGENCY. ADJUST DAMPERS AND FANS TO OBTAIN AIR QUANTITIES WITHIN 5% OF THOSE INDICATED ON THESE DRAWINGS. OBTAIN FULL LOAD AMPS READINGS FOR ALL MOTORS AT BALANCED CONDITIONS. RECORD OUTDOOR AND INDOOR DRY AND WET BULB TEMPERATURES AT BALANCED. SUBMIT ALL TEST AND BALANCE REPORTS TO OWNER FOR APPROVAL. FLOOR/ CEILING STRUCTURE MIN 26 GA. FLAT MTL STRAP HANGERS SECURED TO STRUCTURE END VIEW REFRIGERANT LIQUID LINE. CONN. TO INSULATION W/ PLASTIC STRAP. REFRIGERANT SUCTION LINE CONTINUOUS INSULATION w ----5 U P PLY AIR DUCT A/C UNIT UNIT — REFRIGERANT— PIPING C ACCESS PANELS FACING DOORWAY RUBBER PADS (4) 1 a. FINISHED FLOOR 1 1 /2 "x1 1 /2 "x1 /4" ANGLE WELDED STEEL STAND W /PLATES ANCHORED TO SLAB. ALTERNATE CAN BE 2 "x4" WOOD VERTICAL AND HORIZONTAL SUPPORTS. TYPICAL UNIT INSTALLATION. N.T.S. • y V y vu• V REVISION BY SEAL: o REFRIGERANT LIQUID LINE. FLOOR/ CEILING .. 00 LL -- CONN. TO INSULATION W/ STRUCTURE ��__� PLASTIC STRAP. MIN 26 GA. FLAT � VI REFRIGERANT SUCTION LINE MTL STRAP HANGERS CONTINUOUS INSULATION SECURED TO STRUCTURE w SADDLE REFRIGERANT PIPING HANGER- w ----5 U P PLY AIR DUCT A/C UNIT UNIT — REFRIGERANT— PIPING C ACCESS PANELS FACING DOORWAY RUBBER PADS (4) 1 a. FINISHED FLOOR 1 1 /2 "x1 1 /2 "x1 /4" ANGLE WELDED STEEL STAND W /PLATES ANCHORED TO SLAB. ALTERNATE CAN BE 2 "x4" WOOD VERTICAL AND HORIZONTAL SUPPORTS. TYPICAL UNIT INSTALLATION. N.T.S. • y V y vu• V REVISION BY SEAL: NORTH DRAWN BY: MER !/31/05 SCALE: —� AS NOTED SHEET NO.: r M °G .. 00 LL } 0 U co 00 Z 2 � VI LL LO 1 0 W z 0 w NORTH DRAWN BY: MER !/31/05 SCALE: —� AS NOTED SHEET NO.: r M °G