05-1332-003N0. DOOR SCHEDULE DOORS 9 DENOTES COMPOSITION, FIN15H AND HARDWARE } 0 U SiZE COMP051TION © ._..._..._....._._------ FINISH HARDWARE �- -._... ,`'�.\ --- p z q too Q +/- 22' -10" o u u no C► $' -�" W z W u p LU TYP 4 0 FCl z WIND BUCK, O 41-1 1/211 --J LU 0L (L REMARKS 6' -6" 13/6" • 1 • • 1 • 1 • 15WINr, poop, NOTE: 1) EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN DOOR FROM INSIDE OF CLOSET. 2) EVERY BATH DOOR SHALL BE DESIGNED TO ALLOW OPENING FROM OUTSIDE DURING AN EMERGENCY WHEN LOCKED. 3) EVERY HALLWAY DOOR SHALL HAVE PASSAGE TYPE LOCKSET 4) ALL GLAZING iN DOORS TO COMPLY W/ FEDERAL STANDARD 16 CFR 1201. GLAZING TO BE CATEGORY 11, CAPABLE TO WITHSTAND A 400LB. IMPACT. N� WINDOW SCHEDULE WINDOWS ! DENOTES C01-I 051TION, FINISH AND HARDWARE DESIGNATION TYPE x FINISH GLASS = RELOCATED ELEC { u� u x x I a LU Wz NEW A 0 K U O REMARKS A (2) 3' -0" X 3' -0" • FLORIDA RM 9 • INTERIOR CLEAR C=LASS - STYLE WIDTH TO MATCH EXIST. WINDOWS B 2' -0" X 3' -0" • • CLEAR GLASS- STYLE WIDTH TO MATCH EX15T. WINDOWS PART. SAFETY GLAZING NOTE: WHERE NOTED ON WIND. SCHEDULE, GLAZING TO COMPLY W/ FEDERAL STANDARD 16 CFR 1201. GLAZING TO BE CATEGORY 11, CAPABLE TO WITHSTAND A 4001-5. IMPACT. LEGEND: NEW CMU WALL PER STRUCT DWG'S W/ STUCCO FiN. TO MATCH EXIST AND R -4.1 FOIL INSUL AND 1/2" GYP BD. EXIST. 8" CMU WALL TO REMAIN EXISTING INTERIOR PARTITION TO REMAIN. NEW INTERIOR PARTITION W/ 20 GA. 3 -5/8" MTL STUDS Q 24" O.C. 4 3" SOUND ATTENUATING INSUL. W/ 5/8" GYP BD EACH SIDE. NOTES: ALL PLUMBING AND ELECTRICAL FIXTURES TO BE SELECTED BY OWNER 4 G.C. ALL MILLWORK TO BE SELECTED BY OWNER 4 G.G. (EXISTING) (EXISTING) (EXISTING) (EXISTING) SCOPE OF _- .i• • • i••U• -•Y•- w• V V V y v V u40 V i V V .. • V u KEY MOTES O New 4" cone. slab on 6x6 wwm. over vapor barrier on well compacted fill. Ceiling: 1/2" drywall on i "x3" metal hi -hats at 16" on O center. Typical unless otherwise noted. 5/8" drywall on 3/4" MIN furring strips at 24" on dcenter with R -4.1 AI -Foil insulation. Typical on new perimeter concrete block walls unless otherwise noted. 5/8" drywall on 1 5/8" x 3 5/8" 25 ga. metal studs at 24" on O center. Typical for interior partitions unless otherwise noted. OArched gyp. bd. soffit. coordinate hgt of peak w/ owner Stucco on lath over 5/8" plywood secured to bottom chord of trusses w/ 8d nails 0 6" o.c. Gyp. bd. niche from 36" aff to 56" aff w/ arched top and wood sill 0 36" afF O 2211 x 36" attic access. Provide latches on all four sides. O AT SHOWERS AND TUBS PROVIDE FULL HEIGHT CERAMIC TILE AT WALLS AND ON FLOORS ALL OTHER INTERIOR WALL5 TO NAVE PAINTED DRYWALL FINISH. ALL OTHER FLOORS TO NAVE TILE OR WOOD FINISH WITH WOOD WALL BASE MOLDING. AT ALL WALL HUNG ITEMS PROVIDE 20 GA. MTL. STUDS 16" O.G. W/ 2" X 6" BLOCKING. ALL EX15T WINDOWS TO HAVE PRODUCT APPROVED HURRICANE SHUTTER PROTECTION SEPARATE PERMIT REQUIRED FOR ALL EXTERIOR WINDOWS, DOORS AND SHUTTERS. V V w u V u u w wY • u • w • v • • w Y Y • V • Y V • Y Y V w • • • Y V • V • y y • V • Y Y • Y V u YUY w•• • • yVUVU •i• YYVV • Y • V U • Y • y • Y j•if V Y V w Y • • V • • Y � u • ,.••V • VVUVU i VVi • YV•V • ADDITION ARE,4 0 LL } 0 U 00 L---------- © ._..._..._....._._------ - -_... ----- �- -._... ,`'�.\ --- p z q too Q +/- 22' -10" /41-011 $' -�" 14' -10" TYP 4 FCl O WIND BUCK, O 41-1 1/211 _� x = RELOCATED ELEC x x I SRVICE i NEW x TYP p FLORIDA RM INTERIOR PART. I TYP CLG r C7 N LE EL - FIN FL EL -5 IJ 0' -0" TYP WALL `a ( +10.54' NGVD) SECTION O I - '` in RELOCATED ELEC / SERVICE / --- ----------------- z i= X iu FLOOR PLAN SCALE: 1/4" = V -0" 'REVISION BY it NOTE: ALL I DRAWINGS FOR THIS PROJECT ARE TO I,BE READ IN CONJUNCTION WITH EACH OTHER. THESE INCLUDE, BUT ARE NOT LIMITED TO: ARCHITECTURAL, SURVEYING, STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, SPECIALTY DRAWINGS, & WRITTEN SPECIFICATIONS. CONTRACTOR TO VERIFY ALL EXISTING SITE CONDITIONS AND THOROUGHLY CHECK ELEVATIONS AND DIMENSIONS BEFORE COMMENCING WORK. REPORT TO THE ARCHITECT ENGINEER ANY DISCREPANCIES, ERRORS OR CONDITIONS THAT WILL ALTER CONSTRUCTION AS INTENDED BY THESE DRAWINGS. ARCHITECT IS NOT RESPONSIBLE FOR ANY WORK AND /OR MATERIALS FURNISHED ON THE JOB. All graphic material appearing herein, unless indicated otherwise, are the property of the Architect as instruments of service for use solely on this project, and may not be duplicated, used or disclosed without the written consent of Mark E. Reardon, R.A. The architect retains all common law, statutory and other reserved rights. z:: • �'. SEAL: I NORTH DRAWN BY: MER DATE: 8/31/05 SCALE: AS NOTED SHEET NO.: Fi 0 LL } 0 U 00 © U) �- w p z q too Q NORTH DRAWN BY: MER DATE: 8/31/05 SCALE: AS NOTED SHEET NO.: Fi