Loading...
05-66-013"NUTONE" 50 CFN EXH. FAN UP T( ROOF JACK "NUTONE" 50 EXH. FAN U ROOF . °O 2 WAY 50 CFM 6X6 CB N5,4TH CD BATH 2 WAY 50 CFM p 6X6 CB EXTERIOR 6" ABV. GRADE BLDG. TERMINATED FACE DN. OF STRUCTURE, & TO BE 2" CD LINE TO OUTSIDE BEDROOM #1 TO 1st FLR BEDROOM #2 AIR TRANSFER AIR TRANSFER 12" x 12" 10" x 10" THROUGH CEILING THROUGH CEILING 1 CB N1�JI 1508 CFM 1OX8 CB 150 CFM 6 "0 1 WAY ® FILE 4 "0 FLEX 3/4" SECTION LI 3/8" LIQUID LINE (THROUGH DROP CEILING) DN TO 1st FLOOR 1118ri 1 WAY 50 CFM FL 6x6 CB CL CL 16"x8" 1 WAY ® 0 CFM 4 "0 X6 CB 1 WAY 6 ,� 150 CFM p +'A/ 10X8 CB FLEX 4 AIR TRANSFER FLEX 12" x 12 ",,"' THROUGH CEILING BEDROOM #4 SECOND FLOOR MECHANICAL PLAN N 1/4 it = 1' -0" OUTDOOR AIR CALCULATIONS AREA DESIGNATION FLOOR AREA PERSONS TOTAL PERSONS CFM PERSONS CFM Q.FT CFM REQUIRED CFM PROVIDED SYSTEM DESIGNATION S.F.R. 3,171 ROOMS 6 15 N. A. 90 90 INFILTRAT. FIRE STOPPING 80' 80' SMOKE CONTROL VOLTS .--76-0-/-230 O 1 60 230 6 "0 PHASES MECHANICAL CODE - UNDERGROUND CONDENSATE DRAIN LINE SHALL BE 2 INCHES DIAM. MINIMUM. - ANCHORING DETAIL OF THE CONDENSING UNIT TO THE CONCRETE SLAB TO WITHSTAND 146 M.P.H. WIND FORCE. (AS PER 301.13 F.M.C. 1619.2 F.B.C.) - ALL EXHAUST DUCTS SHALL BE CONSTRUCTED OF SHEET METAL, TERMINATE OUTSIDE THE BUILDING, AND BE EQUIPPED WITH A BACKDRAFT DAMPER AND SCREEN. (NO T -FIN ALLOWED) - ALL TOILET ROOMS SHALL BE PROVIDED WITH A MECHANICAL EXHAUST SYSTEM TO PRODUCE 1 COMPLETE AIR CHANGE EVERY 3 MINUTES, WHERE THE THE VENTILATING AIR HAS BEEN CONDITIONED, THERE SHALL BE A COMPLETE AIR CHANGE EVERY 7 1/2 MINUTES.- (AN A/C DROP IN THE TOILET ROOM FOR AN INTERIOR BATHROOM IS NOT SUFFICIENT OR ACCEPTABLE MEANS OF VENTILATION.- AN EXHAUST FAN SHALL BE PROVIDED.W /50 CFM MIN) - DUCTS FROM "TOILET ROOMS" SHALL DISCHARGE TO THE OUTSIDE OF THE BUILDING, SHALL BE TERMINATED NOT LESS THAN 6 INCHES ABOVE THE FINISHED ROOF SURFACE, AND SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL HAVING A MESH SIZE NOT LARGER THAN 1/2 INCH. (PROVIDE GOOSE NECK OR RAIN CAP ON ROOF TERMINATIONS)* *FOR THE PURPOSE OF THIS PARAGRAPH, THE TERM "TOILET ROOM" SHALL BE CONSTRUED ALSO TO MEAN BATHROOMS, SERVICE SINK ROOMS, AND JANITOR'S CLOSETS. - CLOTHES DRYER EXHAUST DUCT SHALL NOT BE SCREENED. 4" DIA. MIN. - CLOTHES DRYERS EXHAUST DUCTS (OR VENTS) SHALL COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF A MINIMUM 30 GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCTS JOINTS SHALL NOT BE ASSEMBLED WITH SHEET METAL SCREWS OR OTHER FASTENERS WHICH EXTEND INTO THE DUCT. CONDENSING 2" WIRE STRAPS =1 /8" UNIT POWER & CONTROL CONNECTIONS 6" MIN. 6" MIN. 4" MIN. FASTEN C.U. DIRECTLY TO LIQUID LINE SLAB W/ 1/4'y 0 X 3" LNG. W/O INSULATION TAPCON SCREWS 4" 0 SCHEDULE • • • 40 P.V.C. PIPE INCREASE SIZE CONCRETE BASE W/ AS REQUIRED BY 6 X 6 - 10/10 WWF 6" MIN. LENGTH AND ROUTING SUCTION LINE W/ 1-1/2" ARMAFLEX INSULATION SEAL ENTRANCE OF REFRIGERANT & VAPOR BARRIER LINES INTO P.V.C. PIPE W/ IMPERMEABLE, RESILENT MATERIAL C.U. MOUNTING DETAIL 1 WAY FLE FLEX CL AIR TRANSFER 20" x 20" BATH THROUGH CEILING 1 WAY 50 CFM 6X6 40 19 FLEX (D j 1 WAY �—� 4" 75 CFM '1 X6 CB �" T °0 Ilk FLEX a 1 WAY 50 CFM 6X6 CB CL /ri,,: aa11 � C (ri ill AIR TRANSFER 10 x 10 "0 THROUGH CEILING 10X8 CB 150 CFM 1 WAY BEDROOM #3 3l4" RELEIF LINE TO SPPILL OUTSIDE OF BLDG. 6 ABOVE FIN, Z ^? 3/4" SECTION LINE 3/8" LIQUID LINE (THROUGH CEILING) UP TO 2nd FLOOR "NUTONE" 50 CFM EXH. FAN UP TO ROOF JACK J APPENDIX "A" SCHEDULE HVAC DESIGN REQUIRES YES NO DUCT SMOKE DETECTOR CFM 1030 FIRE DAMPER(S) BTUH 28,400 SMOKE DAMPER(S) BTUH SENSIB 21.3 FIRE RATED ENCLOSURE ENTE G W.B. FIRE RATED ROOF /FLOOR CEILING ASSEMBLY 67' ENTERINT7 FIRE STOPPING 80' 80' SMOKE CONTROL VOLTS .--76-0-/-230 O EF -1 BATH EXHAUST FAN NUTONE MODEL C -350 50 CFM 110-1-60 W/ THERMOFIN TO ROOF JACK TERRACE Illlglq • • E401MIlllmllllllllll�llllllll G,4R,4GE 3/4" SECTION LINE 3/8" LIQUID LINE (THROUGH CEILING) GARAGE VENTILATION CALCULATIONS THE NEW FLORIDA MECHANICAL CODE ALLOWS NATURAL VENTIIIATION AS ONE OF THE MEANS TO VENTILATE THE GARAGE, FROM ASHR E GUIDE AND DATA BOOK Q = VAE WHERE Q = 100 CFM PER CAR. V = WIND VELOCITY AT 4 MPH = 3Z2 FT PER MINUTE A = SQUARE FEET OF FREE AREA OF WALL OPENING WITH SCREEN LOUVER. E = EFFECTIVENESS WITH WIND DIAGONAL TO WALL. A = Q /VE = 100 CFM /352 FPM X 0.3 = 0.947 SO. FEET. AF EA = 0.947X144 SQ.I N /FT. A = 136 SO. IN. OF NET FREE AREA. A MINIMUM OF ONE INL T AND ONE kOUTLET ARE REQUIRED IN TWO EXTERIOR WALLS /DOOR. PROVIDE 2 -8" X 16" VENT 1" ABOVE FINISH 'LOOR AT GARAGE (100 S.I. PER VEHICLE MIN. EXTERIOR 2" CD LINE TO OUTSIDE OF STRUCTURE, & TO BE TERMINATED FACE DN. 6" ABV. GRADE 0 BLDG. 8"x8" 5X5 CB 50 CFM 1 WAY_ 112%8" 8X8 CB 75 CFM 1 WAY F 4 "0 FLEX AC SPLIT SYSTEM SCHEDULE FAN COIL ITEM FC -1 FC -2 CFM 1030 1600 BTUH 28,400 48,000 BTUH SENSIB 21.3 36.0 ENTE G W.B. 67' 67' ENTERINT7 D.B. 80' 80' FACTORY FABRICATED VOLTS .--76-0-/-230 O 1 60 230 6 "0 PHASES 10 10 1 HEATING KW 10.0 10.0 � WIRE AMPS FUSES #6 60A #6 60A FLEA` MANUFACTURER YORK YORK CCU MODEL F2RC FC030 I F2FP048 CONDENSING UNIT ITEM CU -1 CU -2 CFM 1030 1600 BTUH 95' 95' 2 WAY VOLTS 1/60/230 1 60 230 < PHASES 10 10 (BY A/C CONTRACTOR) WIRE AMPS 10# 10 L� FUSES 30A 30A MANUFACTURER YORK YORK r MODEL H4DH030S06 H4DH048S06 2 WAY "NUTONE" 50 CFM 75 CFM SEER 12.0 12.0 AIR COND. (NOTES) PROVIDE AUXILIARY DRAIN PAN W /FLOAT SWITCH AS PER SECTION 307.2.4 (FMC) PROVIDE AIR TRANSFER AT EVERY BEDROOM ROOF CEILING FAN COIL UNIT l' PROVID FLOAT SWITCH AS PE 307.2.4. IT IS — SUPPO DOWN THE A/C UNIT AUTOMATICALLY TO PREVENT OVERFLOW. CONCRETE SLAB 12" MIN DRAIN AREA tr SOIL GRASSED AREA - f& C- -I -III I I III —I f QP 2" CONDENSATE _III DRAIN PIPE CONDENSATE DRAIN DRY WELL TO 2nd FLR DINING olu, TOX8 C8 150 CFM 1 WAY 60 FLEX sq, 111111 I�I�IIIIIIIIIIIIII��I >Alll�lllllllll� 1Ig1 ga 1111111 EXTERIOR 2" CD LINE TO OUTSIDE OF STRUCTURE, & TO BE TERMINATED FACE DN. 6" ABV. GRADE 0 BLDG. KITCHEN 1OX10 CB 200 CFM 4 WAY N.T.S O REF, fPANTFIY c.o. STORAGE 16"x8" ALL 4' LIQUID AND SUCTION AROUND FLEX CLOSET CL d3 co 0.ayt LINES ELECTRIC STRIP 81$0 �� 10X8 CB 100 CFM 1 WAY .. ❑ — FIBERGLASS SUPPLY DUCT FLEX 0.�° .j-0 R -6 MINIMUM- wSULAT: -k ;.;,�y P RFORATED CAP FACTORY FABRICATED 6X6 O 6 "0 •. FILTER SECTION C-Z FLEX ALL 4' LIQUID AND SUCTION AROUND FLEX CLOSET CL Lai LINES ELECTRIC STRIP 81$0 �� 10X8 CB 100 CFM 1 WAY .. ❑ CD FLEX HEATER TOP OF CFMI P RFORATED CAP FACTORY FABRICATED 6X6 O 6 "0 •. FILTER SECTION C-Z FLEX 4" 0 � � FLEA` 2" SCH 40 PVC DRAIN ^' CCU < (BY A/C CONTRACTOR) 8"�O \RNMONEMONN 12 "x8" BOTTOM OF �ef ci - p DRAIN PAN DRAIN PAN TO BE AT LEAST 6' 0 1 WAY � 150 CFM 4 "� MA5TE 3" LARGER THAN A.H.U. 2 WAY (ALL SIDES AND 1.5" DEEP) FLEX 6X6 CB FLEX BAT 2" SCH 40 PVC UND DRAIN (BY A/C CONTRACTOR) TYPICAL A.0 EQUIPMENT CLOSET N.T.S TO CONDENSATE DRAIN LINE A/C UNIT DRAIN CONNECTION INSTALLATION OF PIPING TO CLEAR FILTER PULL OUT AREA & SERVICE REMOVABLE PANELS CONDENSATE DRAIN ARRANGEMENT AT AIR CONDITIONER UNIT N.T.S FAM I L'T' 10X8 CB 200 CFM 1 WAY MASTER BEDROOM AIR TRANSFER 14" x 14" THROUGH CEILING 10X8 CB 10X8 CB 125 CFM 125 CFM WAY 19 1 WAY 6 "0 12 "0 FLEX FIRST FLOOR MECHANICAL PLAN N "NUTONE" 50 CFM EXH. FAN UP TO ROOF JACK FLEX CLOSET CL Lai 81$0 �� 10X8 CB 100 CFM 1 WAY .. ❑ CD FLEX 1 WAY CFMI 6X6 O 6 "0 •. C-Z FLEX 4" 0 � � FLEA` CCU < 8"�O \RNMONEMONN 12 "x8" 8 "x8" 'LEX - p L I V INCA 6' 0 1 WAY � 150 CFM 4 "� MA5TE 2 WAY FLEX 6X6 CB FLEX BAT 200 CFM O � 10X8 CB CD L� v a DEN I r � 2 WAY "NUTONE" 50 CFM 75 CFM EXH. FAN UP TO ° 8) 8 CB ROOF JACK i FIRST FLOOR MECHANICAL PLAN N "NUTONE" 50 CFM EXH. FAN UP TO ROOF JACK 11/21 s s n z w c C3 ID w w ID �° 01 o o N 3� n O N c 0 O n �� o O .^ N w 3 o w w O 0 .Ln U L4 N 0 N /03 z • • D 11 0 D A 2 o- �m o _� r- O CD Z U) _ Cn Z O O O m n r Ln F7 — m z D n O c r J --I co 2 m I � � D � � D I - z V1 0') r- m O O KA VY 1V ti Y J. _N1. - K. C. m DATE: = 05 -10 -2004 SHEET \` Lai y® C CD � O C-Z (-D I � � CCU � 0 O � CD L� v I r � 11/21 s s n z w c C3 ID w w ID �° 01 o o N 3� n O N c 0 O n �� o O .^ N w 3 o w w O 0 .Ln U L4 N 0 N /03 z • • D 11 0 D A 2 o- �m o _� r- O CD Z U) _ Cn Z O O O m n r Ln F7 — m z D n O c r J --I co 2 m I � � D � � D I - z V1 0') r- m O O KA VY 1V ti Y J. _N1. - K. C. m DATE: = 05 -10 -2004 SHEET \`