05-66-012TYPE: NEMA 3 -R SERVICE: APARTMENT VOLTAGE 121240 x 30 Wall Switch 15 A, 125 V LOT 20 -BLK 1 MAIN BUS: 200 AMP PANEL "A" NEUTRAL: 200 AMP ELECTRIC SCHEDULE MAIN LUGS ONLY -LOCATION: SHOWN Duplex Receptacle 15 A 125 V OIncandescent Light Fixture OLight Fixture/ HIGH HAT Wall Bracket Light B4 THRU 7 CIRCUIT BRK. WIRE LIGTHS & RECEPTACLES USE REMARKS LIVE NEUTRAL 20 12 1/2" RECEPTACLES W /GFI BATH B -941 A -1 THRU 12 15 14 1/2" LIGTHS & RECEPTACLES (2696x3W) 8088 8088 X13 THRU 16 20 12 1/2" SMALL APLIANCES 1500 3000 3000 A -17 20 12 1/2" RECEPTACLES W /GFI BATH A -18 A -19 -21 ................_._._ .._ ..................._..._..._ A -20 -22 A -23 -25 A -24 -26 ....................................................... _ A -27 -29 20 20 ._._....................._. 20 60 30 ..._....................._. 50 12 12 ............ .............. 12 2 #5 2#10 ................. ...._......._._._._._._._._................................................................................................. 3 #8 1/2" 1/2" ................................... 3/4" 314" 3/4" 1" REFRIGERATOR DISHWASHER ................ .................................................................. ...................................................... GARBAGE DISPOSAL AIR CONDITIONING UNIT AIR COMPRESSOR UNIT ...................................................... RANGE AND OVEN (10W) ...................................................... _...... 100% + 125 %FAN N.C.L. ........ ................ . ...................... ............. 70 % NEUTRAL 1500 1500 ............................ _._.-.._....... 500 10000 1500 ..................... ... ...__._._._......... 10000 1500 1500 _._._.................................... 500 7000 A -28-30 30 2#10 3/4" WATER HEATER 4500 TOTAL CONNECTED LOAD LESS A/C LOAD A -31 20 12 1 " WASHER 1500 1500 A -32-34 30 3#10 1" DRYER REMAINDER AT 35% 3615 5000 3500 A -33 20 12 3/4" WHIRLPOOL PUMP 48 1500 1500 A -35 20 12 3/4" GARAGE DOOR OPENER 1500 1500 A -36 A -37 20 20 12 12 3/4" 3/4" POOL PUMP SPRINKLER 1500 1500 1500 1500 A -38-39 60 3#6 ROMEX SUB -PANEL "B" A-40 SPARE FEEDERS NEUTRAL LIGHTS, RECEPTACLES, SMALL APPLIANCES & WASHER 12588 LIVE TOTAL CONNECTED LOAD LESS A/C LOAD 41588 DEMAND LIVE FIRST 10 KW. AT 100% 10000 REMAINDER AT 40% 31588 AIR CONDITIONER LOAD AT 100% 12635 10000 DEMAND NEUTRAL FIRST 3KW. AT 100% ._ ....................._._._._._._.__.............T..._._._._._._................................_......_............................_.................... REMAINDER AT 35% ._._._._._..................... 9588 3000 _.__._... ..........._....._._._._...._._ 3356 TOTAL WATTS 32635 19856 TOTAL AMPS T 136 T-83 CODE LANGUAGE: 210.12(B) DWELLING UNIT BEDROOMS ALL BRANCH CIRCUITS THAT SUPPLY 125.VOL, SINGLE — PHASE, 15 AND 20 AMPERE CU -LETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL B- PROTECTED BY AN ARC — FAULT CIRCUIT INTERRUPTER LISTED TO PROVIDE PRO- ECT'IION 0= THE BRANCH CIRCJIT. TYPE: NEMA 3 -11 LOT 20 - BLK 1 MAIN BUS: 60 AMP SERVICE: APARTMENT PANEL "B" NEUTRAL: 60 AMP ELECTRIC SCHEDULE VOLTAGE 121240 x 30 MAIN LUGS ONLY - LOCATION: SHOWN Wall Switch 15 A, 125 V Duplex Receptacle 15 A 125 V OIncandescent Light Fixture OLight Fixture/ HIGH HAT Wall Bracket Light B4 THRU 7 15 14 1/2" LIGTHS & RECEPTACLES (1205x3) 3615 3615 B-8 20 12 1/2" RECEPTACLES W /GFI BATH B -941 60 2 #5 3/4" AIR CONDITIONING UNIT 100% + 125 %FAN 10000 B -1042 30 2 #10 3/4" AIR COMPRESSOR UNIT N.C.L. 1500 B43 THRU 20 SPARES FEEDERS NEUTRAL LIGHTS, RECEPTACLES, SMALL APPLIANCES & WASHER 3615 LIVE TOTAL CONNECTED LOAD LESS A/C LOAD 3615 DEMAND LIVE FIRST 10 KW. AT 100% 0 REMAINDER AT 40% 3615 AIR CONDITIONER LOAD AT 100% 1446 10000 DEMAND NEUTRAL FIRST 3KW. AT 100% 0 REMAINDER AT 35% 3615 1265 TOTAL WATTS 11446 1265 TOTAL AMPS 48 5 METER /MAIN COMBINATION W/ 200 AMP. 2" RGC TO POWER COMPAf TRANSFER PAD # 4 CONDUCTO SECTION OF FC Z II Z //-1 -1 I I A I !-I ELECTRICAL RISER N.T.S. # 6 THWN CU(GROUND) 10,000 AIC 200 AMP. E_ECT. PANEL MIL 0 S.N. 2 # 8 —HWN. CU. IN 3/4" COND. TO EACH CONDENSER. #1 2 POLE -30 AMPS BKR. LOAD =5.50 KW #2 POLE -40 AMPS BKR. LOAD =4.10 KW * NOTE: LOCATE C.U. W /IN 20' OF ELEC -. METER -OUSE CONCRETE = OUNDATION # 5 FOUNDATION REBAR MIN 20 FT LONG ELECT. LEGEND 4' Flourescent Light Fixture OJunction Box PH D Phone Outlet TV T.V. Outlet LEI Disconnecting Switch ®D Smoke Detector Electrical Meter KITCHEN OR BATHROOM LIGHT. SMOKE DETECTOR NOTE: SMOKE DETECTOR SHALL BE HARDWIRED (1 0 VOLT TYPE) TO A NON— SWITCHABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT, WITH BATTERY BACK —UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER. ALL SMOKE DETECTORS WITHIN -ACH UNIT SHALL BE INTERCONNECTED. SMOKE DETECTOR CONNECTION DETAIL N TS. ELECTRICAL NOTES: 1. OUTSIDE RECEPTACLES, RECEPTACLES AT BATH, GARAGE AND 6 FEET FROM KITCHEN SINK, SHALL BE G.F.I. 2. SMOKE DETECTOR HARDWIRED TO KITCHEN OR BATHROOM NON - SWITCHABLE NO G.F.I. LIGHTING CIRCUIT INTERCONNECTED AND WITH BATTERY BACK -UP. 3. ELECTRICAL METER AND PANEL LOCATION MAY VARY AS PER SERVICE ENTRANCE LOCATION. 4. ELECTRICAL CONTRACTOR TO COORDINATE SERVICE WITH F.P.L. 5. ALL "J" BOXES SHALL COMPLY WITH N.E.C. 370 -17A. 6. APPLIANCES BREAKERS AND WIRING AS PER MANUFACTURES SPECIFICATIONS 7. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THESE IN THE HABITUAL AREAS. 8. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION. 9. A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION 10. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION. 11. IT IS SUGGESTED THAT YOU CONFER WITH FLORIDA POWER AND LIGHT TO LOCATE THE ELECTRICAL METER TO COMPLY WITH FEDERAL EMERGENCY MANGEMENT AGENCY REQUIREMENTS 12. NEC -110 PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING CHECK NAME PLATE DATA OF A/C EQUIPMENT, HOT WATER HEATERS AND OTHER EQUIPMENT TO OBTAIN CORRECT PROTECTION. ADECUATE SERVICE CAPACITY, MUST BE PROVIDED SUBJECT TO ELECTRICAL INSPECTION. .. eo lt-t (D O MM I--d N N CD I--1 O C CD � Q O F CD I � � O �p c+ � O ~ I C � I r � Cz C'0o � co � Cz C• 11/21/03 0 v • Ln 0 Z u c n in Ln m O N y -�_ D C Lq �w Wo 0 • N N W N 0 N z • 0 D C_ • AC 0 >__ O -1 N m G7 V 0 -+ m • .__lam • m r O cn z m m Ln V) oz z m co OC D C7 = r �I -< D 00 D m D C o W 0° O D m z 0 Ln m = O N DRAWN BY: J. M. — K. C. 02 -08 -2005 SHEET E-2 Wall Switch 15 A, 125 V Duplex Receptacle 15 A 125 V OIncandescent Light Fixture OLight Fixture/ HIGH HAT Wall Bracket Light 4' Flourescent Light Fixture OJunction Box PH D Phone Outlet TV T.V. Outlet LEI Disconnecting Switch ®D Smoke Detector Electrical Meter KITCHEN OR BATHROOM LIGHT. SMOKE DETECTOR NOTE: SMOKE DETECTOR SHALL BE HARDWIRED (1 0 VOLT TYPE) TO A NON— SWITCHABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT, WITH BATTERY BACK —UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER. ALL SMOKE DETECTORS WITHIN -ACH UNIT SHALL BE INTERCONNECTED. SMOKE DETECTOR CONNECTION DETAIL N TS. ELECTRICAL NOTES: 1. OUTSIDE RECEPTACLES, RECEPTACLES AT BATH, GARAGE AND 6 FEET FROM KITCHEN SINK, SHALL BE G.F.I. 2. SMOKE DETECTOR HARDWIRED TO KITCHEN OR BATHROOM NON - SWITCHABLE NO G.F.I. LIGHTING CIRCUIT INTERCONNECTED AND WITH BATTERY BACK -UP. 3. ELECTRICAL METER AND PANEL LOCATION MAY VARY AS PER SERVICE ENTRANCE LOCATION. 4. ELECTRICAL CONTRACTOR TO COORDINATE SERVICE WITH F.P.L. 5. ALL "J" BOXES SHALL COMPLY WITH N.E.C. 370 -17A. 6. APPLIANCES BREAKERS AND WIRING AS PER MANUFACTURES SPECIFICATIONS 7. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THESE IN THE HABITUAL AREAS. 8. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION. 9. A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION 10. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION. 11. IT IS SUGGESTED THAT YOU CONFER WITH FLORIDA POWER AND LIGHT TO LOCATE THE ELECTRICAL METER TO COMPLY WITH FEDERAL EMERGENCY MANGEMENT AGENCY REQUIREMENTS 12. NEC -110 PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING CHECK NAME PLATE DATA OF A/C EQUIPMENT, HOT WATER HEATERS AND OTHER EQUIPMENT TO OBTAIN CORRECT PROTECTION. ADECUATE SERVICE CAPACITY, MUST BE PROVIDED SUBJECT TO ELECTRICAL INSPECTION. .. eo lt-t (D O MM I--d N N CD I--1 O C CD � Q O F CD I � � O �p c+ � O ~ I C � I r � Cz C'0o � co � Cz C• 11/21/03 0 v • Ln 0 Z u c n in Ln m O N y -�_ D C Lq �w Wo 0 • N N W N 0 N z • 0 D C_ • AC 0 >__ O -1 N m G7 V 0 -+ m • .__lam • m r O cn z m m Ln V) oz z m co OC D C7 = r �I -< D 00 D m D C o W 0° O D m z 0 Ln m = O N DRAWN BY: J. M. — K. C. 02 -08 -2005 SHEET E-2