Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-1333(3)-003
O ELECTRICAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA 70 (NEC 2002) AND FBC 2004. 2 PROVIDEALL REQUIRED CONNECTIONS FOR OTHER TRADES, INCLUDING TEMPORARY POWER. 3. OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT. 4. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS, WHEN APPLICABLE 5. ALL EQUIPMENT HAS BEEN RATED AS INDICATED IN PANEL SCHEDULE. ELECTRICAL CONTRACTOR TO BE REPONSIBLE TO NOTIFY THE ELECTRICAL ENGINEER IF ANY CHANGE IN MANUFACTURER SPECIFICATIONS PRIOR ORDERING. 6. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED FOR A COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS. 7. EQUIPMENT AND ELECTRICAL WIRING IN OR ADJACENT TO SWIMMING POOLS, WHIRPOOLS, SPAS AND FOUNTAINS TO COMPLY WITH NEC 680. ALL UNDERWATER LUMINARIES TO BE FED BY A LOW VOLTAGE TRANSFORMER 8. DISCONECTING MEANS ASSOCIATED WITH APPLIANCES TO COMPLY WITH NEC 422.111 9. ALL ELECTRICAL WIRING IN CEILING PLENUMS SHALL BE PLENUM RATED IN ACCORDANCE WITH F.B.C. AND N.E.C. SEE A/C AND ARCHITECTURAL PLANS FOR EXACT AREA LOCATION. 10. COORDINATE ALL LIGHTING FIXTURES WITH MECHANICAL AND PLUMBING TRADES BEFORE ROUGH -IN, PARTICULARLY IN RECESSED TYPES. NOTIFY A/E OF ANY DISCREPANCIES. 11. COORDINATE EXACT LOCATION OF DROP AND LUMINUOUS CEILING AREAS WITH ARCHITECTURAL DRAWINGS. 12. VERIFY EXACT LOCATION OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLAN BEFORE ROUGHING -IN. 13. COORDINATE ALL BOXES EXACT LOCATION WITH BUILDING ARCHITECTURAL FEATURES. 14. ALL OUTLETS MOUNTED ON COMMON WALL BETWEEN ROOMS SHALL NOT BE MOUNTED BACK TO BACK. THEY SHAL BE STAGGERED TO PREVENT SOUND TRANSMISSION. 15. THERMOSTAT WIRING SHALL BE DONE BY ELECTRICAL CONTRACTOR PER DIAGRAMS BY UNIT MANUFACTURER. SEE MECHANICAL DRAWINGS FOR EXACT LOCATION. 16. ALL BATHROOMS, GARAGES, OUTDOOR LOCATIONS, KITCHEN AND WET BARS RECEPTACLES SHALL BE PROTECTED BY GFCI (NEC 210.8(A)J. 17 RECEPTACLES AND ELECTRIC BOXES INSTALLED OUTDOORS TO BE WEATHERPROOF PROTECTED (NEC 406.8) 18. ALL WIRING SHALL BE COPPER THHW/THWN/THW EXCEPT OTHERWISE HAS NOTED. OTHER TYPES MAY BE USED IF ACCEPTED BY CODE. 19. INDOOR CONDUIT SHALL BE EMT, EXCEPT FOR BASEMENT. 20. NO RECEPTACLES SHALL BE LOCATED ABOVE KITCHEN SINK. RECEPTACLES IN TOP OF KITCHEN OR BAR COUNTER SHALL BE PROVIDED WITH GFCI PROTECTION. 21. ALL DUPLEX RECEPTACLES SHALL BE 12OV- 15120A 2P -3W GROUNDED, STANDARD GRADE, COLOR CODING. RECEPTACLES SHALL BE MANUFACTURED BY SLATE DECORATOR SERIES OF COLOR SELECTED BY ARCHITECT, EXCEPT OTHERWISE HAS NOTED. 22. ALL CONDUITS SHALL BE CONCEALED IN CEILING, WALL OR FLOOR. 23. ALL RECEPTACLES SHALL BE WIRED IN ACCORDANCE WITH NEC TO ENSURE CORRECT POLARITY. 24. PROVIDE FIRE STOPS IF ALL ELECTRICAL CONDUITS CROSSING FIRE RATED CEILING AND /OR WALLS. CONSULT WITH ARCHITECT BEFORE PROCEEDING WITH ANY PENETRATION THROUGH WALL AND CEILING. 25. ALL DUPLEX RECEPTACLES SHALL BE INSTALLED IN VERTICAL POSITION AT + 18 "AFF MINIMUM. 26. ALL CIRCUIT BREAKERS IN ALL PANELS, DISTRIBUTION PANELS, ETC., MUST BE CLEARLY IDENTIFIED ON DOOR SCHEDULE OR WITH PLASTIC STRIPS AFFIXED PERMANENTLY TO PANEL DOOR. ALL PANELS, D.P., ETC. MUST BE STENCILED ON THE OUTSIDE DOOR OR TO HAVE A PLASTIC LABEL SHOWING NAME OF PANEL, VOLTAGE, AND PHASE AS SHOWN ON THIS SET OF PLANS. 27, ALL CB FOR HVAC AND REFRIGERATION SYSTEMS SHALL BE HACR LISTED (NEC 440.21). 28. PROVIDE EMPTY CONDUITS WITH PULL WIRE FOR TELEPHONE, DATA /COMM. CABLING AND CAN SYSTEMS AS REQUIRED BY UTILITY CO. 29. LCC DENOTE LIGHTING CONTROL SYSTEM. COORDINATE WITH THE LIGHTING CONTROL PLANS AND SCHEDULE WHERE APPLICABLE. 30. ALL SWITCHES, RECEPTACLES, PANELS AND LIGHT FIXTURES SHALL MATCH EXISTING ONES WHEN APPLICABLE. 31. ELECTRIC RANGE RECEPTACLE TO BE 120124OV- 50A -3P-4W GROUNDED, FLUSH MOUNTED AND +20" MAX. AFF. 32. ELECTRIC DRYER RECEPTACLE TO BE 120124OV- 30A -3P -4W GROUNDED, FLUSH MOUNTED AND +44" MAX. AFF. 33. ALL SMOKE DETECTOR WITH BATTERY BACK -UP AND BUILT -IN BUZZER (120V, 85 dB @ 10J TO COMPLY WITH F.B.C., NFPA 101 AND NFPA 72. MULTIPLE DETECTORS TO SOUND SIMULTANEOUSLY DURING ALARM. 34. ALL SMOKE DETECTOR TO BE CONNECTED TO LIGHTING CIRCUITS AT THE SAME CIRCUIT, HOT ALL TIME AND TO BE AFCI PROTECTED. 35. ALL BRANCH CIRCUITS THAT SUPPLY 120V, 15120A OUTLETS INSTALLED IN BEDROOMS SHALL BE PROTECTED BY AN AFCI (NEC 210.12(B)J. TYPE., LOAD CENTER MAIN BUS: 150A SERVICE: HOUSE PANEL A NEUTRAL: 150A VOLTAGE: 1201240V, I PH, 3W MAIN: MLO MOUNTING: FLUSH AICS: IOK OUTSIDE IL Q Z ~-_4 h . NEVI S NEUTRAL: PANEL MAIN: AICS: REMARKS O U O U REMARKS ~ y Z~ h ~ Q J Q pZ U - - - - - SPACE 1 J 2 4 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 SPACE - - - - - POOL PUMP (2 HP MAX) - - - - - SPACE 3 SPACE - - - - - (MLO) 60 2 10900 R 6 AHU -2 5 C /U -2 8 R 8510 2 50 - 7 5,940 20 2 560 R 12 FAN COIL WINE CUELLAR 9 DOUBLE OVEN 8 R 8900 2 40 12 20 2 1200 R 12 VACUUM 11 GEN. LTS. & REC. 50 2 12000 R 6 RANGE (FOR PROVISION) 13 SPACE - - - - - - 15 SPACE - - - - - 14 20 1 540 R 12 FAN /LTS, 17 SPACE - - - - - 1 20 1 1500 R 12 WASHER 19 SPACE - - - - - - 20 1 1500 R 12 SMALL APP. 21 DISH WASHER 12 R 900 1 20 1 20 1 1500 R 12 SMALL APP. 23 DISPOSAL 12 R 560 1 20 1 20 1 1500 R 12 SMALL APP. 25 IGNITOR 12 R 180 1 20 1 20 1 1200 R 12 GAR. DOOR OP. 27 WARMER 12 R 1000 1 20 1 20 1 680 R 12 GAR. DOOR OP. 29 TRASH COMP. 12 R 1000 1 20 1 - - - - - SPACE 31 MW (DOUBLE) 12 R 1800 1 20 1 20 1 680 R 12 ICE MAKER 33 EXT. LIGHTS 12 R 1200 1 20 - 20 1 900 R 12 ENTRY GATE 35 SPACE - - - - - - 20 1 600 R 12 EXT. LTS. 37 SPACE - - - - - - - - - - - SPACE 39 PER. LTS. (PL) 12 112 1200 1 20 - - - - - - SPACE 41 SPACE - - - - - SEE LOAD CALCULATIONS FEEDER: SEE RISER FED FROM: SEE RISER A F-EELECTRIC:AL SYMBOL LEGEND 60A /2P/10K NCTION BOX QF /L LIGHTING FIXTURE W1 SPECIAL SUPPORT FOR FAN & LIGHT (3) #6 THWN (CU) JO LS A FOR LANDSCAPE LIGHTING (WEATHERPROOF) - IN) #8 THWN CONDUIT) (G) O VAPOR PROOF (60 W /MAX.) EMERG. GEN. METER MAIN O CEILING FIXTURE 15 KW IN WEATHER i4 O 1201240V PROOF ENCLOSURE I0OA /2P COMBO (N3RJ O RECESS LIGHTING FIXTURE (N3R) 400A (320 A RATED) @ MINI RECESS LIGHTING FIXTURE 1--0 WALL MOUNTED FIXTURE (60 W /MAX.) WALL MOUNTED FIXTURE O WALL WATCH ^ TO F.P.L. TRANSFORMER WALL SCONE RUNNING UNDERGROUND (�Q SPOT LIGHT - (1) #6 BARE (CU) ® GARAGE MOTOR DOOR OPENER (1) 518"X 10' GND. ROD 4 GARBAGE DISPOSAL 17 I EXHAUST FAN L _ J DUPLEX RECEPTACLE (+ 18"A ) (3) #6 THWN (CU) (1) #8 THWN (CU) (G) IN 314" CONDUIT 15OAl2PI10K � - 200A /2P /IOK' i- 60A /2P/10K (1) #2/0 BARE (CU 3/4" CWP TO FOUNDATION STEEL BAR AS PER NEC 250.52 (A) 2 SET OF. (3) #310 THWN (CU) IN 2" CONDUIT EACH SET. OUTSIDE I GARAGE PNL "A„ 150A (MLO) J I_ (3) # 1/0 THWN (CU)� M#6 THWN (CU) (G) ` (3)#310 THWN (CUJ N 1_1. 2 CONDUIT (1) #6 THWN (CU) (G) IN Z' CONDUIT (3)#8 THWN (CU) (1) #8 THWN (CU) (G) IN 314" CONDUIT ELECTRICAL RISER 1 NTS QUADRUPLEX RECEPTACLE ( +18 "A.F.F.) GROUND FAULT INTERRUPTER ri) E C T R I C A L INSTALLATION BELOW FLOOD LEVEL RICAL DEVI CES BELOW BASE FLOOD ELEVATION SHALL BE 4) ALL DEVICES BELOW FLOOD CRITERIA SHALL BE G.F.I. GROUND FAULT INTERRUPTER OVER COUNTER LED AT THE HEIGHT PERMITTED INDEPENDENT 5) MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD INSTALLED ON A DEDICATED AND SEPARATE ELEVATION AND SHALL BE e- SINGLE RECEPTACLE CIRCUIT FROM THOSE IN THE HABITABLE AREAS. 2 POLE OUTLET (RANGE) 2) NO APPLIANCES OR APPLIANCES OUTLETS SHALL BE INSTALLED WP WEATHER PROOF (@ RECEPTACLE, PROVIDE BUBBLE COVER) BELOW THE BASE FLOOD ELEVATION. Q ELECTRICAL PANEL 1= DISCONNECT SWITCH TOGGLESWITCH (36 "A.F.F.) 3 3 WAY TOGGLESWITCH (36 "A.F.F.) HOME RUN V TELEPHONE OUTLET(+18"A.F.F.) O2 P PHOTOELECTRIC SMOKE DETECTOR WALL MOUNTED SMOKE DETECTOR C GARAGE DOOR OPENER CONTROLLER TELEVISION OUTLET © FLOURESCENT RECESS FIXTURE CONNECT TO NORMAL POWER. tFIELD COORDINATION NOTE EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE -FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/ ENGINEERS 1F ANY CONFLIC OCCUR PRIOR ITS INSTALAVON, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. ELEVATION. 6) WE WILL CONFER WITH F.P.L. OR THE UTILITY CO. TO LOCATE THE ELECTRICAL METER TO COMPLY WITH THE FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. ENTER TYPE SERVICE: HOUSE VOLTAGE. 120 124OV,1 PH,3W MOUNTING: FLUSH OUTSIDE PANEL ( N 3 R) 1 I (POOL PAD) . NEVI S NEUTRAL: PANEL MAIN: AICS: (3) # 1/0 THWN (CU) O U 0 (1) #6 THWN (CU) (G) I Q Z N U IN 2" CONDUIT ~ Q O> REMARKS pZ U 30 PNL 1 w PNL 1 PNL Q Q J a ,B., I 2760 P,. E„ 3 POOL PUMP (2 HP MAX) 1 200A HEAT PUMP 6 150A 100A 11000 2 60 (MLO) I 4 (N3R) (MLO) 2 2760 112 (N3R) - IRRIGATION PUMP (2 HP MAX) 5 6 SPACE - FINISH FLOOR (3) # 1/0 THWN (CU)� M#6 THWN (CU) (G) ` (3)#310 THWN (CUJ N 1_1. 2 CONDUIT (1) #6 THWN (CU) (G) IN Z' CONDUIT (3)#8 THWN (CU) (1) #8 THWN (CU) (G) IN 314" CONDUIT ELECTRICAL RISER 1 NTS QUADRUPLEX RECEPTACLE ( +18 "A.F.F.) GROUND FAULT INTERRUPTER ri) E C T R I C A L INSTALLATION BELOW FLOOD LEVEL RICAL DEVI CES BELOW BASE FLOOD ELEVATION SHALL BE 4) ALL DEVICES BELOW FLOOD CRITERIA SHALL BE G.F.I. GROUND FAULT INTERRUPTER OVER COUNTER LED AT THE HEIGHT PERMITTED INDEPENDENT 5) MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD INSTALLED ON A DEDICATED AND SEPARATE ELEVATION AND SHALL BE e- SINGLE RECEPTACLE CIRCUIT FROM THOSE IN THE HABITABLE AREAS. 2 POLE OUTLET (RANGE) 2) NO APPLIANCES OR APPLIANCES OUTLETS SHALL BE INSTALLED WP WEATHER PROOF (@ RECEPTACLE, PROVIDE BUBBLE COVER) BELOW THE BASE FLOOD ELEVATION. Q ELECTRICAL PANEL 1= DISCONNECT SWITCH TOGGLESWITCH (36 "A.F.F.) 3 3 WAY TOGGLESWITCH (36 "A.F.F.) HOME RUN V TELEPHONE OUTLET(+18"A.F.F.) O2 P PHOTOELECTRIC SMOKE DETECTOR WALL MOUNTED SMOKE DETECTOR C GARAGE DOOR OPENER CONTROLLER TELEVISION OUTLET © FLOURESCENT RECESS FIXTURE CONNECT TO NORMAL POWER. tFIELD COORDINATION NOTE EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE -FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/ ENGINEERS 1F ANY CONFLIC OCCUR PRIOR ITS INSTALAVON, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. ELEVATION. 6) WE WILL CONFER WITH F.P.L. OR THE UTILITY CO. TO LOCATE THE ELECTRICAL METER TO COMPLY WITH THE FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. ENTER TYPE SERVICE: HOUSE VOLTAGE. 120 124OV,1 PH,3W MOUNTING: FLUSH Q PANEL ( N 3 R) � � P ~ O� . NEVI S NEUTRAL: PANEL MAIN: AICS: I SOA MLO 10K O U 0 O U 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 Q Z N U O N ~ Q O> REMARKS pZ U 30 ZO U REMARKS w Z w U AHU -3 Q Q J a 20 2 2760 112 12 3 POOL PUMP (2 HP MAX) 1 2 HEAT PUMP 6 314 AHU-4 11000 2 60 R 3 4 15 20 2 2760 112 12 - IRRIGATION PUMP (2 HP MAX) 5 6 SPACE - - R - - - 5,940 7 8 SPACE - - - - - 12 20 2 2760 112 12 20 BLOWER (2 HP MAX) 9 10 SPACE - - GEN. LTS. & REC. - - - 2 11 12 POOL LTS. (LV) 12 112 900 1 20 15 - - - - - 20 SPACE 13 14 SPA LTS. (LV) 12 112 GEN. LTS. & REC. 900 1 20 R - - - - - 1 SPACE 15 16 SPACE - - 12 - - - 20 - - - - - 12 SPACE 17 18 SPACE - - 2 - - - 1 * R FEEDER: SEE RISER CALCULATED LOAD(AS REQUESTED BY POOL CONTRACTOR) 1 130A @ 240V = 31,200 VA FED FROM: SEE RISER GEN. LTS. & REC. 23 GEN. LTS. & REC. FAR NC HANDLE TIE TYPE: LOAD CENTER p MAIN BUS: 200A SERVICE: HOUSE PANEL I I I' NEUTRAL: 200A B VOLTAGE: 120 124OV,1PH,3W MAIN: MLO MOUNTING: FLUSH AICS: IOK Q ta O> ~ O� ~ 3y REMARKS O U 0 O U 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 REMARKS `" �h Z `= Oh ~ Q O> O Q 30 2 5325 R 10 AHU -3 1 C /U -3 12 R 2300 2 15 8,000 3 8,900 30 2 5325 R 10 AHU-4 5 C /U-4 12 R 2300 2 15 SPRINKLER PUMP 7 0 - - - - - SPACE 9 GFI BATH 12 R 0 1 20 5,940 - - - - - SPACE 11 ALARM 12 R 0 2 20 DISHWASHER 20 1 * R 12 GEN. LTS. & REC. 13 GEN. LTS. & REC. 12 R 0 2 20 0 20 1 * R 12 GEN. LTS. & REC. 15 GEN. LTS. & REC. 12 R OTHER LOAD 120V 2 20 1,600 20 1 2,960 R 12 GEN. LTS. & REC. 17 GEN. LTS. & REC. 12 R * 2 20 10,000 20 1 * R 12 GEN. LTS. & REC. 19 GEN. LTS. & REC. 12 R * 2 20 30,430 20 1 * R 12 FOUNT. LTS. & REC. 21 GEN. LTS. & REC. 12 R 17 2 20 GENERAL LIGHT, WASHER AND SMALL APP. 20 1 * R 12 GEN. LTS. & REC. 23 GEN. LTS. & REC. 12 R 3,129 2 20 10,948 20 1 * R 12 GEN. LTS. & REC. 25 GEN. LTS. & REC. 12 R * 2 20 0 20 1 * R 12 GEN. LTS. & REC. 27 GEN. LTS. & REC. 12 R * 2 20 37 20 1 * R 12 GEN. LTS. &REC. 29 GEN. LTS. &REC. 12 R * 2 20 20 1 * R 12 FOUNT. 31 GEN. LTS. & REC. 12 R 2 20 20 1 * R 12 GEN. LTS. & REC. 33 GFI BATH 12 R * 2 20 - - - - - SPACE 35 SPACE - - - - - - - - - - SPACE 37 SPACE - - - - - - - - - - SPACE 39 PNL "P' 1/0 R 31,200 2 150 - - - - - SPACE 41 SEE LOAD CALCULATIONS FEEDER: SEE RISER FED FROM: SEE RISER A AFCI * 3VA /SQ -FT. (LING. LOAD) LOAD CALCULATION PNL'A" PNL 'B" PNL 'E" SERVICE SQUARE FEET OF CONDITION SPACE 0 6,500 0 6,500 GENERAL LIGHTING AT 3 W.S.F 0 19,500 0 19,500 SMALL APPLIANCES CIRCUITS 3 0 1 4 SMALL APPLIANCES LOAD 4,500 0 1,500 6,000 RANGE / OVEN OR COOK TOP 8,000 0 0 8,000 DOUBLE OVEN 8,900 0 0 8,900 DRYER 0 0 0 0 HOT WATER HEATER 0 0 0 0 SPRINKLER PUMP 0 0 0 0 POOL EQUIPMENT 0 0 0 0 SPA EQUIPMENT 0 0 0 0 OTHER LIGHTING 5,940 0 1,340 7,280 WASHER 11500 0 0 11500 REFRIGERATOR 680 0 2,040 2,720 DISHWASHER 900 0 0 900 DISPOSAL 560 0 0 560 CEILING FANS 0 0 0 0 GARAGE DOOR OPENER & GATE MOTOR 1,880 0 0 11880 WHIRPOOL 0 0 0 0 OTHER LOAD 120V 3,980 0 1,600 51580 OTHER LOAD 240V 2,960 31,200 0 34,160 CONNECTED LOAD WITHOUT A/C LOAD 39,800 50,700 6,480 96,980 FIRST 10000 AT 100% 10,000 10,000 6,480 10,000 RESTAT40% 11,920 16,280 0 34,792 A/C LOAD AS PER NEC 220 -30@ 8,510 6,925 5,132 20,567 TOTAL 30,430 33,205 11,612 65,359 AT 240 VOLT 127 138 48 272 NEUTRAL LOAD CALCULATION U/D REF. 17 18 SPACE GENERAL LIGHT, WASHER AND SMALL APP. 11,940 19,500 2,840 34,280 FIRST 3000 AT 100% 3,000 3,000 2,840 3,000 REST AT 35% 3,129 5,775 0 10,948 RANGEAT70% 5,600 0 0 5,600 DOUBLE OVEN AT 70% 6,230 0 0 6,230 DRYER AT 70% 0 0 0 0 OTHER LOAD 13,940 0 4,980 18,920 TOTAL NEUTRAL LOAD 31,899 8,775 7,820 44,698 AT 240 VOLT 133 37 33 186 A "REVISION BY _ OWNER CHAN E 01123106 - - - &AS BUILT ELEC. - ^ - 06101107 COOOD. - _ 4 06127107 I NOTE: CONTROL WIRING TO OTHER ARC. FAULT CB INTERRUPTER PROTECTION. SMOKE DETECTOR INSIDE THE ALL BRANCH CIRCUITS THAT SUPPLY 125 V, SINGLE SAME UNIT. SEE PLANS PHASE 15 AND 20 AMP LIGHTING, RECEPTACLES, SMOKE DETECTOR, ETC. OUTLETS INSTALLED IN DWELLING UNITS NEUTRAL BEDROOM SHALL BE PROTECTED BY ARC FAULT CIRCUIT - INTERRUPTERS) AS PER NEC 210.12 (B) LIGHT OR t' SMOKE J RECEPTCAL nSD DETECTOR LINE SIDE OF SWITCH SMOKE DETECTOR W/ IF APPLICABLE BATTERY BACK -UP TO AFCI SWITCHED LEG 120 V. LINE AS PER NEC SWITCH 210.12(B) SMOKE DETECTOR CONNECTION DETAIL N.T.S. CEILING SMOKE J l I I I I I I I I DETECTOR A/C DIFFUSER AND /OR FLUORECENT LIGHT 1 i SMOKE DETECTOR MOUNTING DETAIL N.T.S NOTE: ALL SMOKE DETECTORS ARE TO BE PHOTOELECTRIC TYPE TYPE: LOAD CENTER MAIN BUS: 100A SERVICE. HOUSE PANEL E NEUTRAL: 100A VOLTAGE. 7201240V,1 PH, 3W MAIN: MLO MOUNTING: FLUSH AICS: IOK Q Q_ �¢ Zti u h 04 h REMARKS O U O ZN u U REMARKS �N 3 h u H �Q 0 a Q 20 1 360 1/2 12 GEN. REC. 1 2 GEN. LTS. 12 1/2 80 1 20 20 1 180 112 12 GEN. REC. 3 4 GEN. LTS. 12 112 80 1 20 20 1 1500 112 12 SMALL APP. 5 6 MICRO. 12 112 800 1 20 20 1 320 112 12 GEN. LTS. 7 8 GEN. LTS. 12 112 400 1 20 20 1 180 112 12 GEN. REC. 9 10 GEN. LTS. 12 1 /2 160 1 20 - - - - - SPACE 11 12 GEN. LTS. 12 112 .300 1 20 20 1 540 112 12 GEN. REC. 13 14 M.W. 12 112 800 1 20 20 1 680 112 12 REF. 15 16 U/D REF. 12 112 680 1 20 20 1 680 112 12 U/D REF. 17 18 SPACE - - - - - 45 2 7895 314 8 AHU -1 19 20 C /U -1 12 112 2530 2 15 21 22 - - - - - SPACE 23 24 SPACE - - - - - SEE LOAD CALCULATIONS FEEDER: SEE RISER FED FROM: SEE RISER 0 A NC PROJECT NUMBER: OS 0035 0 O U 0 A. a 0 O 1 i c� u W a �I M 0 w Cif 'ONO C/] O tn In 9 n U- 4 In c4i N ca OO -'a Z ow UZ �0 W co U Q i DATE 05 -06 -05 SCALE AS SHOWN DRAWN PGB JOB 05_0035 SHEET Em4 • ELECTRICAL • MECHANICAL - PLUMBING . rte. •�U • #r��-'�� In BARRENE.HEA W ► PRESIDENT 2740 S.W. 97 AvE. SUITE #1 OB IW: o MIAMI, FLA. Zn33165 _Q e OFFICE E3 u (305) 552 -9538 PROJECT NUMBER: OS 0035 0 O U 0 A. a 0 O 1 i c� u W a �I M 0 w Cif 'ONO C/] O tn In 9 n U- 4 In c4i N ca OO -'a Z ow UZ �0 W co U Q i DATE 05 -06 -05 SCALE AS SHOWN DRAWN PGB JOB 05_0035 SHEET Em4 • ELECTRICAL • MECHANICAL - PLUMBING aiEn CARLOS M. In BARRENE.HEA W ► PRESIDENT 2740 S.W. 97 AvE. SUITE #1 OB IW: o MIAMI, FLA. Zn33165 _Q e OFFICE E3 u (305) 552 -9538 Z s FAX (305) 917 -4517 L3 W E-MAIL CMB @CMBENG.COM URL WWW.CMBENG.COM L.C. No. E60007150 P.E. No. 00151 1 5 JOSE MORAGAS ELECTRICAL ENGINEER PROJECT NUMBER: OS 0035 0 O U 0 A. a 0 O 1 i c� u W a �I M 0 w Cif 'ONO C/] O tn In 9 n U- 4 In c4i N ca OO -'a Z ow UZ �0 W co U Q i DATE 05 -06 -05 SCALE AS SHOWN DRAWN PGB JOB 05_0035 SHEET Em4