05-1333(2)-023314" THICK (MIN.) PIPE TO OUTSIDE OF TEMPERATURE AND
BLDG. & DISCHARGE 6" ABOVE GRADE PRES. RELIEF VALVE
PROVIDE AIR GAP AS PER CODE)
orN
222
GP�tiC
AIR RELIEF
VALVEAr
ALL RVD(TYP)
NOT WATER SUPPLY
LINE 1100 TEMP.
UNION
HAND HOLE
CLEANOUT
WATER HEATER PAN
(OMIT ON GROUND FLR.)
PAN DRAIN PARALLEL
TO P &T RELIEF
( l 1 /4 -MIM
CHECK
VALVE
FLOW REGULATING
PLUG COCK ��\ �♦
O
wN100.129—
F—Sm
EMBLEM AND J�
RATING PLATE
\_ SHUT-OFF
VALVE
UNION
GAS INLET
DRAIN VALVE
f� HOSE CONNECTION
RETURN LINE FROM CIRCULATING
r LOOP FOR STORED TEMPERATURE
/ (IF USED)
~� LINE TEMP.
CONTROL
ALL BRONZE
CIRCULATING PUMP
COLD WATER
SUPPLY
CYCLONE XHETM
94% EXTRA HIGH EFFICIENCY
TANK -TYPE WATER HEATER
MODEL(BTH -150 @ 100 GAL)
CAS HWH & CIRCULATING PUMP DETAIL
N.T.S.
THIS UNIT IS
3" O PVC PIPE PROVIDE W/
SEALED COMBUSTION
\ SYSTEM.
1
EMBLEM AND
RA TING PLATE
0
°o
10' " ELEV. % u\
V.I.F.
A
I
SEALED DIRECT VENT SIDEWALL
GAS WH VENT. DETAIL
N.T.S.
IST STAGE 2nd STAGE
TOTAL L= I PO-0" G.W.H =150 MBTU
TOTAL MBTUH = 822 /\ RANGE = 200 MBTU
FIREPLACE= 84 MBTU
8.8.0 = 80 MBTU
DRYER= 86 MBTU
GENERATOR =222 MBTU
CAS RISER D IAC RAM
N.T.S.
-ALL PIPING SHALL COMPLY W/ NFPA -54.
-ALL PIPING SHALL BE GALVANIZED METAL PIPE SCHEDULE 40.
-ALL UNDERGROUND GAS LINE SHALL BE PAINTED W/ ASPHALT.
- NO UNDER SLAB PIPING ALLOWED.
- ALL PIPING OUTSIDE OF STRUCTURE RUN ON (5 PSIG.
- (H. P) = I PSIG. (402.25)
- (L.P)= 0.5 PSIG. (402.26)
- F.B.0 2003 FUEL GAS.
NOTE.
FROM REGULATOR ON LINES START LOW PRESS (1 PSIG)
THIS SYSTEM IS ON GAS TANK (MAX. PSI = 5)
CONSEQUENTLY N ° 2nd STAGE GAS REGULATOR
REQUIRED.
CIRCULATING PUMP SPECS:
"GRUNDFOS" MODEL #: UP 15 -1085. 314 "SUPPLY PIPE, MAX.
- TOTAL MAX. PIPE LENGTH. 300 ft
- SUPPLY LINE VOLUME: 24 GALLONS
- 1 125th HP, 1 Speed, Bronze 112" Sweat Housing, 115 Volt, 55 Watts,
1V��N�O,�yv
t�O
EACH A.A. V. SHALL
(NETS
CABINET
TYP. LOCATION OF AIR ADMITTANCE
VENT AT KITCHEN OR BATH
N. T.S.
PERFORATED
VENT CAP.
2
�v
SLOPE 1 /8 "/ FT RTU UNIT
R
UNION
2" MIN, FOR 2-112 TONS
OR LESS, 3" MIN. FOR 3
TONS OR MORE.
CONDENSATE TRAP DETAIL
N.T.S.
ROLLED LEAD FLASHING SET
1 "DOWN INTO PIPE
PLUMBING VENT STACK (BY OTHERS)
APPLY ELASTIGUM ROOFERS CEMENT
AT EDGES OF ROOFING MEMBRANE.
A / FLANGE SET IN ELASTIGUM ROOFERS
CEMENT - PRIME FLANGE BEFORE STRIPPING.
CEL0TEX rWO -PLY STRIPPING
AS SPECIFIED
CELOTEX ROOF MEMBRANE,
AS SPECIFIED
1 �\
NOTE: /
1. SHEET LEAD MINIMUM OF2 -112 LBS. PER SQUARE FOOT.
V.T.R. /PIPE FLASHING DETAIL
110v
THERMOSTAT # 1
CIRCULATING
PUMP
i
THERMOSTAT #2 - - - - --'
RECOVER PIPE DETAIL
N. T.S.
TOP OF PA VING
CONCRETE VALVE BOX —/
CAST IRON FERRULE W/ CAST J%
BRONZE COUNTERSUNK PLUG
HEAVY DUTY 9 "x 9"
ACCESS COVER
f% AND FRAME
CLEAN OUT EXTENSION PIPE
SAME SIZE AS BUILDING SEWER
OR DRAIN AND 6" MAXIMUM.
BUILDING DRAIN OR SEWER
EXTERIOR CLEAN OUT DETAIL
N.T.S.
N.r.s.
CROJECTNUMBER: 05 0035
y.
• ELECTRICAL
• MECHANICAL
N •PLUMBING
CARLOB M.
�o BARRENECHEA
w PRESIDENT
Wa SUITE #10697AVE,
Q MIAMI, FLA.
Za33165
c GFFICE
13. (305) 552•853B
Z z F.
(305) 917.4517
L]
W E -MAIL
CMBQCMBENO.COM
URL
WWW.CMBENO.CCM
L.C. No. EB0007150
P.E.
No. 131360225
ORLANDO RANOEL
MECHANICAL ENGINEER
CROJECTNUMBER: 05 0035
y.