Loading...
05-1333(2)-022CHECK VALVE FLOW REGULATING PLUG COCK RETURN LINE FROM CIRCULATING LOOP FOR STORED TEMPERATURE (If USED) R \_ LINE TEMP. CONTROL ALL BRONZE CIRCULATING PUMP 314" THICK (MIN.] PIPE TO OUTSIDE OF TEMPERATURE AND BLDG. S DISCHARGE 6" ABOVE RADE PRES. RELIEF VALVE _COLD WATER E SUPPLY PROVIDE AIR GAP AS PER CODE) h AIR RELIEF VALVE AT ________--- ---- — UNION ALL RVD(TYP) i HOT WATER SUPPLY LINE 1100 TEMP. HAND HOLE CLEANOUT �\ WATER HEATER PAN (OMIT ON GROUND FLR.) EMBLEM AND J� RATING PLATE 0 SHUT -OFF VALVE UNION GAS INLET DRAIN VALVE HOSE CONNECTION CYCLONE XHETM 94% EXTRA HIGH EFFICIENCY TANK -TYPE WATER HEATER PAN DRAIN PARALLEL - — MODEL (BTH -150 Q 100 GAL J TO PST RELIEF (I 1 14'MIN) GAS HWH & CIRCULATING PUMP DETAIL N. T.S. 0 � 33 g6 Mgt � GE ,b 80 GQ 5Q P < 3IA•0 \0\�G TOR G� �gTU 1� RPM Mg1� RCS FO GPRG R t✓G� pJ 50 • iST STAGE 2nd STAGE 31A o,,k a p 8 0gt� / 8 TOTAL L= 170-0" G. W.H =150 MBTU TOTAL MBTUH = 822 RANGE = 200 MBTU FIRE PLACE = 84 MBTU 8.8.0 =80 MBTU DRYER= 66 MBTU GENERATOR X22 MBTU GAS RISER DIAGRAM N.T.S. -ALL PIPING SHALL COMPLY W/ NFPA -54. -ALL PIPING SHALL BE GALVANIZED METAL PIPE SCHEDULE 40. -ALL UNDERGROUND GAS LINE SHALL BE PAINTED W /ASPHALT - NO UNDER SLAB PIPING ALLOWED. - ALL PIPING OUTSIDE OF STRUCTURE RUN ON (5 PSIG). - (H.P)= 1 PSIG. (40225) - (L.P)= 0.5 PSIG. (402.26) - F.B.0 2003 FUEL GAS. NOTE: FROM REGULATOR ON LINES START LOW PRESS ( I PSIG) THIS SYSTEM IS ON GAS TANK (MAX. PSI = 5) CONSEQUENTLY N ° 2nd STAGE GAS REGULATOR REQUIRED. �d a cE FIREMju 8A P N I't o 25 / E �IA0��G QPG \XA 1 �VVO gTO 35 X50 M E "0u�G PPG � GL �N j (�' �0 2 J 0�QS owlmo ?ROSS 0 t J G RRG� �J G• tnd STR IP it PSG) 5 STP05 2nd PSI) (0.5 �G R SQJ G•" THIS UNIT IS 3 "0 PVC PIPE -� PROVIDE W/ SEALED COMBUSTION SYSTEM. EMBLEM AND RATING PLATE " 4t) 0 6" SEALED DIRECT VENT SIDEWALL GAS WH VENT. DETAIL N. T.S. CIRCULATING PUMP SPECS: 'GRUNDFOS "MODEL #: UP 15 -1085. 314 "SUPPLY PIPE, MAX. - TOTAL MAX. PIPE LENGTH: 300 ft - SUPPLY LINE VOLUME: 2.4 GALLONS - 1 125th HP, 1 Speed, Bronze 1/2" Sweat Housing, 115 Volt, 55 Watts. EACH A.A. V. SHALL BEACCESSIBLE FOR TOP CABINETS SERVICE OR REPAIR. AND VENTED AS PER 1 I ICABINET I 4 "11 CLR. AS PER 917.4 4 ch i 4" TOE REVEAL TYP. LOCATION OF AIR ADMITTANCE VENT AT KITCHEN OR BATH N. T.S. PERFORATED VENT CAP. ^Z SLOPE 1 /8 "/ Fi RTU UNIT ::IrE �- UNION 2 "MIN. FOR 2- 1 /2TONS OR LESS, 3 "MIN. FOR 3 TONS OR MORE. CONDENSATE TRAP DETAIL N. T.S. �f•'b ROLLED LEAD FLASHING SET 1 " DOWN INTO PIPE i PLUMBING VENT STACK (BY OTHERS) APPLY ELASTIGUM ROOFERS CEMENT AT EDGES OF ROOFING MEMBRANE. l FLANGE SET IN ELASTIGUM ROOFERS CEMENT - PRIME FLANGE BEFORE STRIPPING. CELOTEX TWO -PLY STRIPPING AS SPECIFIED CELOTEX ROOF MEMBRANE, AS SPECIFIED NOTE. / 1. SHEET LEAD MINIMUM OF 2-112 LBS. PER SQUARE FOOT. V.T. R. /PIPE FLASHING DETAIL N.T.S. 110v t — — CIRCULATING _ PUMP THERMOSTAT # 1 THERMOSTAT #2 RECOVER PIPE DETAIL TOP OF PAVING La N.T.S. Tao HEAVY DUTY 9 "x 9" ACCESS CO VER AND FRAME r LEAN OUT EXTENSION PIPE 1ME SIZE AS BUILDING SEWER R DRAIN AND 6" MAXIM UM. BUILDING DRAIN OR SEWER EXTERIOR CLEAN OUT DETAIL N.T.S. . +p.� •m m �.m y •�•a i •t�4 • ELECTRICAL a • MECHANICAL � X_ In • PLUMBINC3 CARLOB M. �/ CEO BARRENECHEA W' PRESIDENT AVE. 2740 e #1 0897 ZW , 33 65F� OFFICE Lj„ (305) 552 -8538 FAX Z - (305) 917 -4517 W E -MAIL CMB @CMBEN13.COM LIRL WWW.CMBENO.COM L.C. No. EB001171511 P. E. Na. 0060225 ORLANDO RANGEL MECHANICAL ENGINEER a r , PROJECT NUMBER: 05 0035 � X_ r JUL q, -a6'J 5