Loading...
05-1333(2)-019T GENERAL PLUMBING NOTES 1. ALL WORK SHALL CONFORM WITH FLORIDA BUILDING CODE 2003 EDITION (F.B.C.2001), FEDERAL ORDINANCES GOVERNING THE INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT /ENGINEER. BEFORE SUBMITTING A BID. THE ARCHITECT /ENGINEER. WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED. 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OFALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK. 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND /OR CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING, ELECTRICAL AND SPRINKLER DRA WINGS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. IF DISCREPANCIES, CONFLICTS, INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. 4. INSTALL MATERIALS AND EQUIPMENT IN NEAT AND FIRST CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRACTOR. 5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER, TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR SHALL REMOVEAND .REPLACE, AT HIS EXPENSE, ALL PLUMBING WORK WHICH MAY i-.AVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES. 6. THIS CONTRACTOR SHALL OBTAIN AND PAYALL INSURANCE, FEES, PERMITS, ASSOCIATION DUES, ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, RULES OR ORDINANCES. 7. PROVIDE MEANSTURNISH AND INSTALL". 8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE, 9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL. 10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS, 11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED BY PROPER AUTHORITIES. 12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER. 13. PROVIDE BATHROOM FIXTURES AS SPECIFIED OR AS SELECTED BY OWNER AND TO COMPLY W/F.B.C.2002 ESPECIALLY CHAPTER 6. 14. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE. 15, WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS FOR LOCATION OF UNITS AND DRAINS. 17. ALL SANITARY FITTINGS SHALL BE DIRECTIONAL TYPE. 18. MATERIALS A. COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE TYPE "L" COPPER BELOW GROUND AND TYPE 'M" COPPER ABOVE GROUND, S. COLD WATER PIPES INSIDE OFSLAS SHALL BE TYPE "K" SOFT COPPER INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB. C. SANITARY WASTE AND VENT 4 "0 AND SMALLER SHALL 8E P.V.C., SCHEDULE 40 S. STORM LINES INSIDE BUILDING SHALL BE P.V,C. SCHEDULE 40 E. IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF BUILDING SHALL BE SCHEDULE 40, PVC. F. CONDENSATE DRAINPIPE SHALL BE SCHEDULE 40, PVC PIPE AND FITTINGS. G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" COPPER, MIN. 314" DIA. 19. ALL CEILING PENETRATIONS, JOINTS, & CRACKS SHALL BE CAULKED, GASKETED, WEATHER STRIPPED OR OTHERWISE SEALED TO AVOID ADDITIONAL CONDITIONED AIR TO GO INTO ATTIC SPACE. AS PER F.B.C. 406.1 FIELD COORDINATION NOTE FIRE RATED PENETRATION NOTE FOR FIRE RATED PENETRATION REFER TO ARCHITECTURAL PLANS. EVERY CONTRACTOR SHALL COORDINATE INFIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE -FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/ ENGINEERS IF ANY CONFLICT OCCUR PRIOR ITS INSTALLATION, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. 'a x- MESH REINF. - --------------- -- - - - - -- -- - I 112 "0 CW /HW --- ---- -- ------------------------------------------------ L) I I I I GAL W 900 & 1050 1200 1350 1500 2000 2200 W 3 -6 3 -9 4 -0 4 -//0� ;' 4 -0 5 -0 I I ,r ------- - - - - -- 213L ------------------- - - - - -- -8" m----- - - - - -- 1131. ------- - - - - -- v- I I I I L - 7 -2 I 10 -0 10-0 ' 12 -0 j 12 -0 ! - - -- ------- - - - - -- -- J NON TRAFFIC LID - 4" THICK \ TRAFFIC LID TYPE - 7" THICK MIN. PLAN 22 "0 OPENING FOR Cl FRAME A COVER '\ #5ALL Owl m SECTION --------------------------------------------------------------------------------- 1) 112 "0 CW /HW --- ---- -- ------------------------------------------------ L) 314 "0 CW - 1170 HW GAL 750 900 & 1050 1200 1350 1500 2000 2200 W 3 -6 3 -9 4 -0 4 -//0� ;' 4 -0 5 -0 5 -0 314 "0 HWR / L 7 -2 9 -0 10 -0 10-0 ' 12 -0 j 12 -0 13-0 - -- - -- -- ---------------- - - - - -- ----------------- - - - - -- ------ -------------------- - - - - -- =" ; ' fr T - - - - -- - } -- -------------- - - - - -- ------------------------- D 4 4 -0 4 -0 /4 -6 / 4 -6 46 4 -6 -- - - - - - -- -- - -- - -- - -- - - - - -- -- - ;;' - - - - - - -- - -- — -- -- ------ - - ------ - ----- T. MIN. 3 3 3 3 REINF. 6X610/10 4X4414 CONC. 4000 PSI 28 DAY SEPTIC TANK DETAIL N.T.S. SYMBOL O.F. Z C.O. O F.C.O. C.D. VTR CONK A.F.F. TYP. W. &V. �a H. B. I W.C.O. SD RVD F.D a AD DESCRIPTION OVERFLOW LINE BUILDING SANITARY SEWER LINE VENT LINE CLEAN OUT FLOOR CLEAN OUT CONDENSATE DRAIN COLD WATER HOT WATER HOT WATER RETURN VENT THRU ROOF CONTINUATION ABOVE FINISHED FLOOR TYPICAL WASTE AND VENT UNION GATE VALVE HOSE 8188 WALL CLEAN OUT BUILDING STORM DRAIN PRESSURE - TEMPERATURE RELIEF VALVE FLOOR DRAIN AREA DRAIN WATER PIPING SIZE 72 - -- 1) 112 "0 CW /HW J 1/2 "0 CW L) 314 "0 CW - 1170 HW 314 "0 CW /HW �5 ! 1170 HW �6) 314 "0 CW (D 1 "0 CW 08; 314"0 HW 1 "0 CW - 314 "0 HW 0@01) 1- 114 "0CW-1 "0HW (11) 1114"0 CW I�2) 314 "0 HWR ON SITE SEWAGE TREATMENT AND DISPONSAL SYSTEM I CALCULATION: DATA: -TOTAL A/C SPACE 4772 SF ESTIMATED SEWAGE FLOW CALCULATION AS PER 64E -6.008 TABLE No I (RESIDENCIAL) 3300 SF OF AREA ----- - ------- - ----- -- ------ ---------------- - ------- - ---------------- - ----- -- ------ 400 GPD FOR EACH ADDITIONAL 750 SF ----------------------------------------------------- --- ---- - - - - -- 800 GPD INCREASED 100 GPD AVERAGE FLO W --------------------------------------------------------------------- - - - - -- 600 G.P.D TOTAL SEPTIC TANK: AS PER TABLE No I 501 - -- 600 G.P.D. AVERAGE SEWAGE ------- - ------- - ------- - -------------- -- FLOW DRAINFIELD: AS PER TABLE No III ESTIMATED SEWAGE FLOW (G.P.D) _> 600 RATEABSORSION IN (G.P.D) 0.7 1350 GAL. CAP SEPTIC TANK IS REQUIRED. = 657 SF OF DRAINFIELD AND 857 SF UN08TRUCTED AREA ARE REQUIRED, NOTE: PROVIDE ANTI SCALD VALVE @ EACH SHOWER AND TUB NOTE, ALL TRAPS SHALL BE CONSISTENT W1 FIXTURE OUTLET SIZE. NOTE: ALL FIXTURE SHALL COMPLY W/ F.B.C. TABLE 604.4. I I I I N OTE: ALL TUB AND SHOWER SHALL BE ANTI - SCALDING VALVE ® 110 °, (TYPICAL) N OTE: ALL V,T.R, SHALL BE OFFSET A MIN. OF 4' -0" FROM FIRE SEPARATION WALL. N OTE: NO SPLICE ALLOWED UNDER SLAB. N OTE: ALL PIPES TO DISCHARGE MIN. 12" FROM STRUCTURE N OTE: ALL PLUMBING WATER DEVICE PROVIDE SHUT -OFF VALVE. LEGEND: O.H - OVER HEAD U.S - UNDER SLAB U.G - UNDER GROUND A.A.V. - AIR ADMITTANCE VALVE R. W. - RUN IN WALL inn »I I(m) )" MIN m 0 Y 1- • ELECTRICAL • MECHANICAL 10 La • PLUMBING CARL❑6 M. Q'o BARREN ECHEA W F PRE5I DENT LU 4 2740 # 1 0.97 AvE. 12 o MIAMI, FLA. Za 33165 oOFFICE (305) 552 -8538 7z FA" (305) 917.4517 W E -MAIL CM B @CM BEN 13. COM URL WWW.CMBENGCOM 5,W, 02fid STREET L.C. No. EE3013071 50 P.E. No. 0060225 ORLANDO RANOEL PAVEMENT MECHANICAL- fNG+NEER 18' �SPI��►UL1' N (r50' TOTAL R /W) e SITE PLUMBING PLAN EFROJECTNUMBER: 05_0035 SCALE: 1/13" = 1