Loading...
05-1333(2)-011cv tt 7t DITTO - ROOF PWT a 24' O.0 1'X14' GA. PURF STRAP WITH 4 -16d NAILS E, CONNECTION. (3) 2x8 TOP M SIMPSON SP -8 (EACH 2x8) (4) 2x8 COF2NE 6IMP60N SP -8 (3) 2x8 BASE F 2X6 WD. STUD 12' O.C. FLASHING 4 CC FLASH ING TILE ROOF -TYF TOP OF TB ELEV. 21' -10' FINISH FLOOR PROVIDE MIN. (5) 1'X4' GA. HURR. STRAPS (24' LONG) EACH CORNER W/ 6 -16d NAILS EACH CONNECTION FLUE TOP MIN. 2' -0' ABOVE HIGHEST ROOF WITHIN A 10' -0' RAD. r MTL. CAP CONT. 1/2' CRRIAGE BOLTS a 12' O.C. TOP t£ OF CHIM. ELEV. 28' -8' A.F.G. (2) 2X6 P.T. WD TOP PLATE SIMPSON SP -6 EA. STUD, TOP 4 BOT. -TYP. 2x6 BRACING STUCCO FIN. ON MTL LATH ON FELT ON 5/6' EXT. PLYWD. 5HTG. W 12 -16d NAILS a4' O.C. MTL 5TAP EA. STUD 2X6 WD BOTT PLATE W1 16d NAILS a 6' O.C. PROVIDE DOUBLE I'XI4' GA. PURR. 5TRAP5 a EA. STUD PREFAB. WD TRUSSES �Y 11/2' DRYWALL FIN. ON 2X4 WD. FRAMING (3) 2X4's WD. HEADER MANTLE 4 FIREPLACE FIN. BY INTERIOR DE51GNER U.L. APPROVED PRE -FAB FIREPLACE MAGNA -FIRE BY LENNOX NON - COMBUSTIBLE FINISH FLOOR GNIMNEY SECTION (5) 2x8 CORNERS 2X6 WD. STUD a BELOW ,, - A I GNIMNEY TOP PLAN STUCCO FIN. ON MTL LATH ON FELT ON 5/8' EXT. PLYWD. SHTG FLUE TOP 2x6 BRACING BELOW 9EGURItIYI ANDI FORCED ENTRY I PIRE-VpENTION I. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LBS, APPLIED IN ANY MOVABLE DIRECTION. 2. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK To BE KEY OPERATED FROM EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE KEY CPANGE5 OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED BOLT INSERT. 3. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOCR5. SHALL HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR DOORS. THE INACTIVE LEAF OF THESE PAIRS OF DOCR5 SHALL PAVE MULTIPLE POINT LOCKS WITH 5 /8' MINIMUM THROW BOLT WITH INSERTS. 4. SLIDING GLASS DOCR5 SHALL BE PROVIDED WITH SLIDING DOOR DEAD BOLTS OR A BOLT OR PIN NOT REMOVABLE OR OPERABLE FROM EXTERIOR AT THE JAMB, DEAD, SILL OR AT MEETING MULLIONS, THESE DOCR5 SPALL BE REINFORCED IN THE STRIKE AND LOCK AREA TO MAINTAIN BOLT 5TRENGTH EFFEGTIVENE65, IF NECESSARY, AND SUCH DOORS SHALL PAVE NO 5CREW5 REMOVABLE FROM OUTSIDE WHICH WOULD FACILITATE READY ENTRY FROM OUTSIDE. 5. HINGES ON EXTERIOR OUT SWINGING DOCKS SHALL HAVE NON - REMOVABLE PINS, AND NON - EXPOSED SCREWS. 6. JAI "155 OF ALL EXTERIOR OFFSET TYPE IN -SWING DOORS BE RABBETTED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF LOCKS AND LATCHES. 1. SINGLE, SWINGING, EXTERIOR DOCR5, IF WOOD SHALL BE SOLID CORE OF NOT LESS THAN 1 -3/8' THICK, S. GLA55 AND EXTERIOR DOCR5 SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARDS IN5TITUTE'8 STANDARD 291.1. S. VISION PANELS IN EXTERIOR DOCR5 OTHER THAN GLAZING WITHIN 40' OF THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWINGING DOORS SPALL COMPLY WITH AMERICAN NATIONAL STANDARDS INSTITUTE'S STANDARD 291.1. 10. SLIDING GLASS DOORS AND WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE TRACKS WPEN IN THE LOCKED F051TION AND SO AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MFG5. A550C. STANDARDS FOR FORCED ENTRY RESISTANCE, AAMA 1303.3. EXTERIOR WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITHSTANDING A FORCE OF 150 LB. APPLIED IN AN OPERABLE DIRECTION. 11. FRONT AND MAIN ENTRANCE DOORS SPALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANELS, 12. A NIGHT LATCH, DEADBOLT CR SECURITY DEVICE MAY BE USED ON EXIT DOCR5 FROM A DWELLING UNIT, HOTEL GUEST ROOM OR SUITE FROVIDED SUCH DEVICES ARE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT AND THE DEVICE 15 MOUNTED AT A HEIGHT NOT TO EXCEED 48 INCHES 0219 MM) ABOVE FINISH FLOOR, AS PER FBC (1026.4) FLOOR PLAN LEGEND: OA REFRIGERATCR W/ ICE MAKER ® DOUBLE SINK W/ DISPOSER OG DISHWASHER OD RANGE/ OVEN SPACE ODOUBLE OVEN W/ WARMING DRAWER OWASHER AND DRYER SPACE VENT DRYER TO EXTERICR O APU , INS. CLOSET PARTITION W/ R -11 ON A/C CONDENSING UNIT PAD (VERIFY SIZE) lO ELECTRICAL PANEL FLUSH MTD. OJ ELECTRICAL METER O ELECTRIC WATER HEATER © LAUNDRY TUB © MICROWAVE SPACE O VANITY 36' A.F.F. O WINE COOLER © 42' HIGH COUNTER W/ 6' PART. BELOW O LINE OF CABINET ABOVE O GARAGE DOOR W/120 5.0. IN. SCREENED VENT. O SHELF 0 22' X 36' ATTIC ACCESS - SEE DTL. A /A -2 O DRYWALL 4 4 WIRE SHELF FIN. LINEN CLOSET O OUTLINE OF RETRACTED GARAGE DOOR O TOP OF ARCP TRANSOM a 9' -6' AFF. OX G.W.B. NICHE W/ LEDGE OY LAV. ON 36' CABS OZ CAT. 11 SAFETY GLASS SHOWER as 42' LAUNDRY COUNTER ® 12' -10' TAPERED CONC. DECORATIVE, KEY STONE FIN., COLUMN. INSTALLED AS PER MFGR. SPECS. 0 36' HIGH BASE CABS ® GAS B.B.Q. PLASMA T.V. fF U.G. ICE MAKER ® U.C. REFRIGERATOR POOR SGNEDUL.E NO. DOOR FRAME REMARKS lU N T MAT TYPE GLA55 MAT DET 1 2(3' -0') 8' -0' 1 3/4' MTL FRENCH CATEGORY II SAFETY GLASS MTL MTL. THRESHOLD, WEATHER STRIP 2 2' -6' 8' -0' 1 3/4' MTL RAISED PNLS INSUL. DOOR WD MTL. THRESHOLD, AUTO CLOSER WEATHER - STRIP IMPACT RESISTANT 3 2' -6' 8' -0' 1 3/4' Wp RAISED PNL5 INSUL. DOOR WD V MTL. THRESHOLD, WEATHER STRIP 4 2(2'-(o') 8 -0 1 3/8 WD HOLLOW GORE RAISED PANEL WD }� Q 5 2' -8- 8' -0' 1 3/8, WD HOLLOW GORE RAISED PANELS WD o MARBLE SADDLE AT BATHROOMS ONLY (TYP.) 6 2' -4- 8' -0' 1 3/8' WD Po 1_ O L J CORE RAISED PANELS A WD MARBLE SADDLE AT BATHROOMS ONLY (TYP.) 1 2' -6- 8' -0' 13/0, WD HOLLOW CORE RAISED PANELS SCALE AS SHOWN WD JOB 0504 MARBLE SADDLE AT BATHROOMS ONLY (TYP.) 8 2(2' -0') 8' -0' 1 318' WD SWING WD FULL LOUVERED 9 2' -4' 8' -0' 13/8' WD SWING WD FULL LOUVERED 10 2' -6' 8' -0' 1 3/8' WD SWING WD FULL LOUVERED 11 2' -0' 8' -0' 13/8' WD POCKET WD FULL LOUVERED 12 2(2' -(o') 8' -0' 1 3/4' MTL FRENCH CATEGORY II SAFETY GLASS MTL MTL. THRESHOLD, WEATHER STRIP 13 2(21-6') 8' -0' 1 3/4' MTL FRENCH CATEGORY II SAFETY GLASS MTL W/ t -36': SIDE LITE WITH CAT II SAFETY GLASS, MTL. THRESHOLD AND WEATHER STRIP 14 2(2' -6') 8' -0' _ 1 3/4' MTL FRENCH CATEGORY II SAFETY GLASS MTL W/ 2 -26'1 SIDE LITE5 WITH CAT II SAFETY GLASS, MTL. THRESHOLD AND WEATHER STRIP 15 2' -0' 8' -O' 1 3/4' WD WINE CELLAR CATEGORY II SAFETY GLA55 WD DOUBLE GLA55 AND FULLY GASKETED 16 8' -0' 8' -0' 13/4' MTL O.H. GARAGE WD W/ 60 50. IN SCREEN VENT WITHIN l' OF FLOOR Il 16' -0' 8' -0' _ 1 3/4' MTL O.N. GARAGE WD W/ 50. w. SCREEN VENT WITHHIN N l' OF FLOOR IS 19 -t- FLOOR PLAN GENERAL NOTES: 1. BATHROOM FLOORS AND BASE TO BE OF IMPERVIOUS MATERIALS AS PER F.B.G. - 20011 401.2.(o SHOWER COMPARTMENTS SHALL HAVE FLOORS AND WALLS CONSTRUCTED OF SMOOTH, CORROSfON RESISTANT AND NONABSORBENT WATER - RESISTANT MATERIALS TO A HEIGHT OF NOT LESS THAN 10 INCHES ABOVE THE COMPARTMENT FLOOR AT THE DRAIN. FBC 1204.3 JOINTS. BUILT -IN TU55 WITH SHOWERS SHALL HAVE WATERPROOFED JOINTS BETWEEN THE TUB AND WATER RESISTANT WALL. FBC 1204.4 2. F5C. 1005.4.2 , 1005.43 4 1005.4.4, IN AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE, THE MODE OF OPERATION SPALL NOT REQUIRE TIDE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE CR EFFORT. SUCH CLEAR OPENING SPALL BE NOT LE65 THAN 20' IN WIDTP, AND 24' IN PEIGHT, 50 50. FT. IN AREA THE BOTTOM OF THE OPENING SHALL NOT BE MCRE THAN 44' ABOVE THE FINISHED FLOOR AND NO PART OF THE OPERATING MECHANISM SHALL BE PLACED HIGHER THAN 54' ABOVE FINISHED FLOOR- 3, NUMBERS OF ADDRESS SHALL BE PLACED VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE PROPERTY AND SHALL BE 3 INCHE5 MIN. IN HEIGHT. 4. REFER TO FOUNDATION PLAN FOR CONCRETE FILLED BLOCK CELL AND COLUMN LOCATION, SIZE AND REINFORCING. 5. ALL GLA35 USED INSIDE OF DWELLING SHALL BE GAT. II 6. CAT. II SAFETY GLASS SHALL BE USED AT ALL SHOWER /TUB ENCLOSURES INCLUDING WINDOWS WITH 511-5 LOWER THAN 60' AND MIRRORS IN THE TUB 1. CLOSET AND BATHROOM DOCR5 EVERY CLOSET DOOR LACHT SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET. EVERY BATHROOM DOCK SHALL BE DESIGN TO ALLOW OPENING FROM THE OUTSIDE DURING AN EMERGENCY WHEN LOCKED. DOORS MAY BE SWINGING OR SLIDING. NO DOOR IN ANY MEANS OF ESCAPE SHALL BE LOCKED AGAINST EGRE55 WHEN THE BUILDING 15 OCCUPIED. ALL DEVICES THAT IMPEDE OR PROHIBIT EGRE55 OR THAT CANNOT BE EASILY DISENGAGED SHALL BE PROHIBITED. 8. ALL OUTSIDE FIXED GLASS AND GLA55 DOOR SHALL BE COMPLY WITH F.B.G. AS PER 2411.3.1.3 AND 2405.21(1) 4 (2) 9. ALL GLASS AT SHOWER ENCLOSURES TO BE 5AFETY GLA55 CAT. II AS PER F.B.C. 2405. 2.1 (2) AND 2411. 3.1. 3. 2 10. TOILET ROOMS SHALL COMPLY WITH SECT. 1204.2 F.B.G. AREA CALCULATIONS 1st FLOOR A/C SPACE 2nd FLOOR A/C SPACE 2,895 SQ. FT 1,816 50. FT TOTAL A/C SPACE 4,111 50. FT GARAGE 643 50. FT COVERED ENTRY 43 50. FT COVERED TERRACE 195 50. FT LOG1A 523 50. FT BALCONY 33 50. FT TOTAL 6,032 50. FT WALL HUNG FIXTURE5 PLEASE SEE DETAIL 3/A -8 GARAGE NOTES: 1. PROVIDE ENCLOSURE AS FOLLOWS: PARTITIONS: I -LAYER 1/2' DRYWALL EACH SIDE. AS PER WITH R -11 BATT INSULATION. CEILING5: ACOUSTICAL SPRAY FINISH ON 1/2' DRYWALL OR PAINTED 1/2' DRYWALL. 2. CONTRACTOR SPALL POST PERMANENT SIGN WITH 1/2' LETTERS ON THE INSIDE FACE OF ANY ONE DOOR TO THE OUTSIDE READING: DANGERI DO NOT OPERATE ENGINES WITH DOOR CLOSED. CARBON - MONOXIDE EMISSION 15 LETHAL. WALL LEGEND; INDICATES 6'x8 'xl6' MASONRY UNITS INDICATES 3 -5/8' METAL 5TUD5 PARTITION 24' O.G. WITH 1/2' DRYWALL FINISH EACH SIDE. INDICATES 3 -5/8' METAL STUDS PARTITION 24' O.C. a WITH 1/2' DRYWALL FIN151­1 EACH 51DE. ` WITH R -11 IN5UL. BETWEEN 8TUD5. REVISION BY W r; LL o V � c 000 u_ }� Q oO ti F-+ Ow 7@ cn O ;� o rZ .R � V � r�H U A � DATE 05 -06 -05 SCALE AS SHOWN DRAWN JC JOB 0504 SHEET A-3 SHEET II OF 28 r1 y r► f 1' V O 11 � X e y 1 REG., N • 4 • t34