Loading...
05-1333(2)-007REINFORCED CONCRETE NOTES 1) STRUCTURAL CONCRETE SHALL CONFORM WITH ACI -318 IT SHALL REACH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI 0 28 DAYS FOR COLUMNS AND BEAMS AND 2500 PSI 0 28 DAYS FOR SLABS & FOOTINGS. 2) MAXIMUM PERMISSIBLE SLUMP IS 5 -6' IN STRUCTURAL CONCRETE WITH THE EXCEPTION BEING SAND CEMENT GROUT 3) AGGREGATES SHALL BE CLEAN AND GRADED MAXIMUM SIZES 3/4' CONCRETE ASTM C -33 SHALL CONFORM TO ASTM C -94 4) NO ADMIXTURES PERMITTED WITHOUT WRITTEN APPROVAL OF ENGINEER 5) CONCRETE TESTING IS REQUIRED AS FOLLOWS. 1 SET OF 5 CYLINDERS FOR EVERY 50 CU. YDS. OF CONCRETE AS PER ASTM C -94 6) CLEAR COVER FOR REINFORCING BARS SHALL BE: FOOTINGS ......... ... .... . . . . . .. 3' UNFORMED FACES .... 3' SLABS ......................... 3/4' FORMED FACES IN BEAMS /COLUMNS ...... 1 1/2' CONTACT W /EARTH..... 2' 7) ALL CONCRETE WORK IN ACCORDANCE WITH ' SPECIFICATIONS FOR STRUCTURAL CONCRETE' (ACI- 301 -99) CODES APPLICABLE CODES- A: F.B.C. 2003 REVISON TO THE 2001 EDITION. B: A.C.I. 318 -02 REINFORCED CONCRETE C: REINFORCED MASONRY BY A.C.I. 530 -02 AND THE MASONRY DESIGNERS GUIDE BY T.M.S.402 -02, A.S.C.E.5 -02 E: WIND ANALYSIS AND DESIGN PER A.S.C.E.7 -98. REINFORCING STEEL NOTES 1) REINFORCING STEEL fy = 60,000 P.S.I. fs = 24,000 P.S.I. Es = 29,000,000 P.S.I. Em = 1,350,000 P.S.I. N = Es /Em = 21.48 2) REINFORCING STEEL SHALL CONFORM TO ASTM A -615 GRADE 60. REINFORCING STEEL SHALL BE DETAILED AND FABRICATED ACCORDING TO THE ' MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES'. HOOK ALL DISCONTINUOUS TOP REINFORCING. PROVIDE CORNERS WITH 215 X 4' -0' BARS. SPLICING NOTES 3) TIE BEAMS & FOOTINGS SHALL BE CONTINUOUS REINFORCEMENT, PROVIDED BY LAPPING SPLICES NOT LESS THAN 30'. CONTINUITY SHALL BE PROVIDED AT ALL CORNERS BY BENDING 2 BARS FROM EACH DIRECTION AROUND THE CORNER 30' (SAME SIZE AND QUANTITY). 4) EXTEND BEAM BOTTOM BARS 8' PAST ALL OPENINGS GREATER THAN S -0' ON BOTH SIDES. 5) CONTINUITY AT COLUMNS SHALL BE PROVIDED BY CONTINUING HORIZONTAL REBARS THRU COLUMNS OR BY BENDING HORIZONTAL REINF. INTO COLUMNS A DISTANCE OF 30'. 6) HOOK TOP OF VERTICAL BARS IN ALL TERMINATING COLUMNS 2' BELOW TOP OF SLAB AND 3' BELOW TOP OF THE TIE BEAM. STRUCTURAL STEEL 1. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING GRADES: A. ALL WF, ANGLE, BASE PLATES, CONN. PLATES (UON) --- ASTM A36 (Fyy--36 KSI) 8. STRUCTURAL TUBE---------------- - -ASTM A500, GRADE 8 l� y--46 KSl) C. STEEL PIPE--------------------- - -ASTM A53, GRADE 8 (�F= -A KSI) 2. GROUT FOR COLUMN BASE PLATES SHALL BE NON- METALUC, NON SHRINK GROUT SUCH AS MASTER FLOW 713, AS MANUFACTURED BY MASTER BUILDERS OR APRROVED EQUAL 3. ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF "THE STANDARD CODE FOR WELDING IN BUILDING CONSTRUCTION' OF THE AMERICAN WELDING SOCIETY. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS USING E70 -XX ELECTRODES. WOOD NOTES 1. ROOF DIAPHRAGM SHALL COMPLY WITH THE DESIGN RECOMMENDATIONS OF 'A.P.A. DESIGN / CONSTRUCTION GUIDE - DIAPHRAGMS' AND THE F.B.C. 2003 REVISION TO THE 2001 EDITION. 2. PLYWOOD ROOF DECKING SHALL BE 5/8' MINIMUM THICKNESS, AND SHALL BE CONTINUOUS OVER TWO OR MORE SPANS, WITH FACE GRAIN PERPENDICULAR TO THE SUPPORTS . 3. CONNECT PLYWOOD DIAPHRAGM TO STRUCTURE WITH 8d GALVANIZED NAILS, SPACED AT 6'o.c. MAX. AT EDGES AND AT 6'o.c. ALONG INTERMEDIATE SUPPORTS. 4' o.c. 0 DIAPHRAM BOUNDARY AND 10d NAILS 0 4' OC 0 GABLE ENDS. 4. INSPECTIONS: SHALL COMPLY WITH THE LOCAL BUILDING CODE REQUIREMENTS FOR INSPECTIONS (BY THE MUNICIPALITY, ARCHITECT OR ENGINEER) OF SPECIFIED COMPONENTS OF THE ROOF STRUCTURE REQUIRING INSPECTIONS. 5. ALL STRUCTURAL LUMBER TO BE SOUTHERN PINE No. 2 OR BETTER. MINIMUM BENDING STRESS, Fb = 1,200 PSI. SHEAR STRESS Fv=90 PSI. YOUNG'S MODULES, E = 1,500,000 PSI. SOIL STATEMENT AFTER VISUAL INSPECTION SOIL CONDITIONS ARE TO BE SAND & ROCK NTH A MIN. BEARING CAPACITY OF 2000 P.S.F. SHOULD OTHER CONDITIONSOR MATERIALS BE ENCOUNTERED, THE ENGINEER SHALL BE NOTIFIED PRIOR TO PROCEEDING WITH THE WORK. THE ARCHITECT OR ENGINEER SHALL SUPPLY A LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED & FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED ON. SEE F.B.C. 2001 EDITION. CHAPTER 1818.2 REINFORCED MASONRY NOTES 1) PROVIDE CLEANOUT OPENING AT THE BOTTOM OF REINFORCED MASONRY CELLS THAT ARE BEING FILLED TO ENSURE THAT THE CELL IS FILLED. PROVIDE WEEP HOLES AT 1/3 AND 2/3 OF SPAN 2) ALL BLOCK MASONRY WALLS SHALL HAVE HORIZONTAL REINFORCEMENT ' DUR -O -WALL LADDER TYPE SPACED 16' ON CENTER. USE PREFABRICATED CORNERS AND TEES BY "DUR -O -WALL AT CORNERS AND JUNCTIONS OF WALLS MASONRY UNITS SHALL BE 2 CELL HOLLOW UNITS CONFORMING TO A.S.T.M. C -90 WITH COMPRESSIVE STRENGTH OF 1900 P.S.I. ON THE NET CROSS - SECTIONAL AREA AND SHALL BE LAID IN RUNNING BOND. MORTAR SHALL BE TYPE "S' 3) MORTAR SHALL COMPLY WITH A.S.T.M. 270 MORTAR SLUMP REQUIRED - - - -- 5' TO 8" TYPE S. f m =1,500 PSI CONTRACTOR TO CONSOLIDATE GROUT LIFTS NTH 314' VIBRATOR 4) WHERE ANCHOR BOLTS ARE SET IN MASONRY WALL, FILL TWO BLOCK CELLS NTH GROUT 0 ANCHOR BOLT LOCATIONS 5) GROUT USED IN THE WORK SHALL CONFORM TO ASTM C476 WITH A SLUMP MIIX OF 8' TO 11', PROVIDE CLEANOUT AND INSPECTION HOLES AT FILLED CELLS AT BOTTOM COURSE. 6) POUR GROUT IN LIFTS NOT TO EXCEED 4' 7) GROUT USED IN THE WORK SHALL OBTAIN A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS. GROUT SHALL COMPLY WITH A.S.T.M. C476. SHOP DRAWINGS PRIOR TO ANY FABRICATION, SHOP DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW. SHOP DRAWINGS ARE REQUIRED, BUT NOT LIMITED TO, FOR THE FOLLOWING: 1. WOOD TRUSSES AND GIRDERS 2. STRUCTURAL STEEL 3. FORMWORK /SHORING /RESHORING 4. REINFORCING STEEL 5. PRECAST CONCRETE STEEL JOIST FLOOR SYSYTEM. GENERAL NOTES 1) A SPECIAL INSPECTION BY A FL CERTIFIED ENGINEER OR SPECIAL INSPECTOR, WILL BE RfWJRED FOR ALL ENGINEERED MASONRY CONSTRUCTION, SOIL COMPACTION AND ROOF TRUSSES OVER 35 LONG OR 6 -0 HIGH. 2) THE USE OF A SCALE TO OBTAIN DIMENSIONS NOT SHOWN ON THE PLANS IS STRICTLY FORBIDDEN. THE ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS RESULTING FROM SUCH ACTIONS. 3) CONTRACTOR TO LOCATE ALL EXISTING UTILITIES PRIOR TO EXCAVATION. 4) ALL SPECIFIED MATERIALS AND CONNECTORS CAN BE SUBSTITUTED NTH EQUAL OR BETTER, NTH THE APPROVAL OF ENGINEER OF RECORD. 5) PRIOR TO CONSTRUCTION PROVIDE TERMITE PROTECTION TREATMENT TO SOIL IN ACCORDANCE WITH "NATIONAL PEST CONTROL ASSOCIATION" STANDARDS DESIGN LOADS WIND DESIGN PER ASCE 7 -98 MEAN ROOF HEIGHT ................................... ..............................+ 26' -3' WIND DESIGN SPEED ............................... ............................... 146 MPH EXPOSURE CATEGORY ............................. ............................... C IMPORTANCE FACTOR ............................. ............................... 1.0 Kd............................................................................. ............................... 1.0 BUILDING COEFFICIENT ( ENCLOSED) ... ............................... +/- 0.18 NET UPLIFTS SHOWN HEREIN ARE BASED ON (CROSS UPLIFT) LESS 10 PSF (DEAD LOAD) PER ASCE COMPONENTS AND CLADDING ZONES 1 AND 2 & 3. ZONE1 ............................................................. ............................... -41.07 PSF ZONE2 & 3 .................................................. ............................... -72.34 PSF ROOF DESIGN LOAD CALCULATIONS ROOF DEAD LOAD TOP CHORD .............................. 15 PSF BOTT CHORD ............................ 10 PSF ROOF LIVE LOAD ................... I.................... 30 PSF WOOD TRUSSES 2ND FLOOR DESIGN LOADS D.L. :..... ............................... 25 P.S.F. LL: ........ .............................40 P.S.F. SIDL. ....... ............................... 25 P.S.F. STAIRS LIVELOAD: ................................... ............................... 40 PSF SECOND FLOOR' SYSTEM NOTES PRECAST CONCRETE STEEL JOIST FLOOR SYSTEM SHALL BE MANUFACTURED IN ACCORDANCE NTH THE FLORIDA BUILDING CODE 2003 REVISION AND THE ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, CORROSION PROTECTED & ERECTED IN ACCORDANCE: WITH THE AISC CODE OF STANDARD PRACTICE, LATEST EDITION. PRIOR TO FABRICATION, SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR REVIEW AND APPROVAL, SIGNED AND SEALED ENGINEER. SEE PLANS FOR DESIGN LOADS. BY A FLORIDA REGISTERED PROFESSIONAL 1. Floor Manufacturer to design precast concrete Floor Elements: FC= 3000 psi at 28 days. 2. All structural steel to be ASTM A36 Fy =36KS1 3. Maximun live load deflection allowable: 1/360 4. The Contractor shall be responsible for the temporary bracing as long as the permanent bracing and the shear connections between the slobs have been made. 8' -0" 8' -0" 8' -0" 8' -0" 0 0 0 1 2 2 ORIDGE O 2 2 2 2 0 2 1 3 O 3 W -0" SAFE LOAD TABLES FOR GRAVITY, UPLIFT & LATERAL LOADS 8" PRECAST & PRESTRESSED U- LINTELS 410~1964milvill GRAVITY TYPE LENGTH 8U'8 8F8 -0B 8F12 -OB 8F16 -OB 8F8 -IB 8F12 -1B 8F16 -1B 2'- 10'(34') PRECAST 2302 3166 4473 6039 3166 4473 6039 3'-6'(42') PRECAST 2302 3138 3377 4689 3166 4473 6039 4' -0' <48') PRECAST 2029 2325 1 2496 3467 2646 1 4473 6039 4'-6'(54') PRECAST 1651 1787 1913 2657 2170 4027 6039 5'-4'(64') PRECAST 1184 1223 1301 1809 1665 2889 5057 5'- 10' <70') PRECAST 972 1000 1059 1474 1459 1 2464 4144 6'-6'(78') PRECAST 937 1255 2101 3263 1255 2101 1 3396 7'-6'(90') PRECAST 767 1029 1675 2385 1029 1675 2610 9'-4'<112') PRECAST 573 632 1049 1469 768 1212 1818 10'- 6'(126') PRECAST 456 . 482 802 1125 ,658 1025 1514 11'- 4'(136') PRECAST 445 598 935 1365 598 1 935 1365 12'- 0'(144') PRECAST 414 545 864 1254 555 864 1254 13' -4 '(160') PRECAST 362 427 726 1028 485 748 1 1076 14'- 0'(168') PRECAST 338 535 600 12'- 0'(144') PRECAST 45 455 700 1043 00 8' -0' F = FILLED WITH GROUT / U = UNFILLED r BOnO OF �NTELE CAVITY AT TYPICAL: 8F8-1 B 19 32" CDX PLYWOOD DECKING NAILED TO TRUSSES 8' -0" W 8d NAILS, AS PER ZONES. NOMINAL WIDTH ZONES: O 8d NAILS 0 6 "o.c. THROUGHOUT. NOMINAL HEIGHT ZONES 1 & O2 • 8d NAILS 0 6 "o.c. THROUGHOUT. *- - 8d NAILS 0 4 o.c. AT EDGES. ZONE 3 8d NAILS 0 4 "o.c. AT EDGES. u i GROUT 8d NAILS ® 6 "o.c. AT INTERMEDIATES. 1CI ROOFPLAN SHOWING ► z . ue- 15 F L.INT�EL CAVITY to °o BOTTOM REINFORCING ZONES 1, 2 3 PROVIDED {N LINTEL 8' -0" 7 -5/8' ACTU _ (VARIES) TYPE DESIGNATION- 8' NOMINAL WD MINIMUN LINTEL REINF: 1# 5 BOTTOM C UPLIFT LATERAL PRODUCT CONTROL NOTICE OF ACCEPTANCE LENGTH TYPE 8F8 -1T 8F12 -11 8F16 -1T 8U11 8F8 F.E.C.P. CORPORATION- CAST -CRETE DIVISION 8F8- 2T 8F12- 2T8F16 -2T 2'- 10'(34') PRECAST 2727 2878 4101 2021 2021 ACCEPTANCE NO.: 01-- 0209.03 EXPIRES: 05/21/06 2727 2784 3981 3'-6'(42') PRECAST 2165 2289 60 2257 1257 2165 2215 3165 4' -0' (48') PRECAST 1878 1989 2832 938 938 1878 1925 2750 9 GAUGE DUR -O -WALL HORIZONTAL REINFORCEMENT EVERY OTHER COURSE (LADDER TYPE) I 4'-6'(54') PRECAST 1660 1762 2507 727 727 1660 1705 2435 5'-4'<64') PRECAST 1393* 1484 2110 505 505 1393 1437 2050 5'- 10'(70') PRECAST 1272* 1357 1930 418 418 1272 272 1315 1875 6'-6'(78') PRECAST 1200 1733 707 887 1141 1182 1684 7'-6'(90') PRECAST 959* 912 591 657 990 1029 9' -4' (112')PRECAST 801* 612 L.79 454 630 801 755 10'- 6'(126') PRECAST 716* 498 396 493 716 611 039 11'- 4'(136') PRECAST 666* 439 696 363 556 666 535 905 12'- 0'(144') PRECAST 1 340 494 631 486 6 13'- 4'(160') PRECAST 500* 340 532 302 398 573 409 682 14'- 0'(168') PRECAST 458* 316 493 286 360 *REDUCE VALUE BY 25X FOR GRADE 40 FIELD REBAR 1 9 GAUGE OUR-O -WALL HORIZONTAL DCIAICA0l1C1AC-UT C1/COV ATIICO PAIMCC 4-4/32" EXTERIOR GRADE PLYWOOD SHEATHING SEE PLYWOOD NAILING DETAIL FOR ATTACHMENT. EXTEND ROOF SHEATHING UNDER VALLEY SET TRUSSES, ANCHOR VALLEY SET TRUSSES TO THE MAIN TRUSSES PAST THE ROOF SHEATHING AS SHOWN TYP I CAL N.T.S. PREFAB. ENGINNERED WD. RUSSES ® 24' O.C. (JAS PER MANUF.SPECS.) PROVIDE " WEDGE FOR SOLID BEARING. ATTACH W/ -16d NAILS (TYP) USP RT16T STRAP X W/ 6 -16 d MAILS AT EACH END, TYPICAL AT 4' -0" O.C. PIGGYBACK DETAIL 8' x 8' x 16' CONCRETE MASONRY UNITS TYPICAL DUR -O -WALL DETAIL SCALE: N.T.S. 8" x 16' CONCRETE SONRY UNITS -O -WALL @ CORNER DETAI ADD 2 #5 REINFORCEMENT BARS FOR EVERY 8" OF DROP :• STIRRUPS (REFER TO TIE BEAM SCHEDULE) �. a 8„ DROP TIE BEAM 0 WINDOW EXTEND DROP OF TIE BEAM AND DOOR OPENINGS 8" BEYOND SIZE OF OPENING AT EACH END 8„ OPENING FOR WINDOW, DOOR OR SLIDING DOOR. SEE FLOOR PLAN & ELEVATIONS TYPICAL DROP TIE BEAM DETAIL SCALE: N.T.S. Alex Kon dra t & Associates, In STRUCTURAL ENGINEERS Alex Kondrat - P.E. #58086 12900 SW 128 Street, Suite 104 Miami, Florida 33186 Ph. (786) 293 -2888 Fax. (786) 293 -2878 ���ll�t�,`�C1�11, p' ,.SrATr s cr �1G'N REVISION 13Y 6i z 0 n O L>_ Q i-- W LLj N 00 N I 1 Ln r) rn t x 12 0 �t- ry tn 0 c� r) z ° L° Q 'rz CD I ° LL Li Q W {- o L z "L'i 00 °w U U J I Z o L 0 (1) _ at (%) cn LLI ai i) U 0 D E C) 2 cv DATE SCALE DRAWN JOB SHEET S-4 SHEET ' OF REG. No. 10, 154